Rotational Molding Troubleshooting

Problem : Long-term part failure

Probable Cause

Possible Solutions

- Use higher oven temperature and/or longer oven time for


undercured parts
Undercured parts

- Improve heat transfer by using air flow amplifier, heat


deflectors or thermal pins
- Ensure that all materials have low moisture content

Overcured parts

- Decrease oven temperature and/or oven time

- Ensure that the type and the amount of additive is sufficient


Improper additive or pigment

- Use the pigments that have high thermal stability, light and UV
resistant and disperses well in the base resin

Low environmental stress cracking resistance


(ESCR)

- Use low MI grade (e.g. MFI 3 )


- Use octene or hexene for stress-proned applicationd

Poor part design

- Avoid stress-contrentation (e.g. sharp corners )

SCG Performance Chemicals Co., Ltd disclaim responsibility for results of use of this information, which is furnished without charge, or of any product, method or apparatus
mentioned herein. It is the users responsibility to make and be guided by their own tests determining the suitability of any such product, method or apparatus for their
purpose. No statement or suggestion herein is to be considered a recommendation or inducement of any use, manufacture or sale that may infringe any patents or
hereafter in existence.
For technical assistance or further information on this grade or any other products, please contact your sales representative or technical service engineer.
SCG Performance Chemical Co., Ltd 1 Siam Cement Road, Bangsue, Bangkok, 10800 Thailand
Tel. +66 2586 4116, +66 2586 5305, +66 2586 4146 Fax +66 2586 3676 E-mail : sirinunm@scg.co.th or rotomolding@scg.co.th

www.chemicals.scg.co.th
Rev. Oct' 09 Valid until next revision

You might also like