Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

represented by:

measurIT technologies

Double baffle controller DB


dry mounted

Flexible solution
• Applicable for larger and large capacities. H
[m]
• A suitable DB controller can be found for
any design flow 30 l/s to 10 m3/s, please
see diagram to the right.
• Fully adjustable baffles (inlet opening).
• This makes it possible to change inflow as
needed with a range of at least +/-25%
relative to its medium capacity. Q [l/s]

• Applicable for all common types of


Application chart
sewage.
• Applicable at even very small heads (from
appr. 40 cm and upwards).
• Requires little space. inlet WL

Effective control H

• Ensures close to constant discharge,


inlet outle
Qdes, virtually regardless of upstream Q
head, H. This is illustrated by the head-
discharge curve sketch to the right.

Definition sketch

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
represented by:

measurIT technologies

Low maintenance/operating
H
costs [m]
• Straight passage (Qdes,Hdes)

• Large passageway
• Horizontal (level) passageway
• No moving parts
• Does not require any power supplies
• Fabricated in acid-resistant stainless steel Q [l/s]
AISI 316L (Werkstoff 1.4404)
Head-discharge curve for DB

Low construction costs


DB
• Can be fitted in existing or designed
manholes or tanks - a separate housing
structure is mostly not required.
• Inexpensive

Typical applications
• At the outlet from detention basins
• In overflow/surcharce structures
• Temporary storage in upstream sewer
system
• At inlet to pumping stations
• At inlet to sand or oil traps and treatment
plants
• And many other situations.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962