Boost Converter Calculator

(3 seperate Calculators)
Frequency Calculator
Input Voltage
Inductor Size
Peak Switch Current
Duty Cycle
Required Switching Frequency
Estimated Power output

12
130
14
55

Volts
H
Amps
%

*Absolute Maximum, 10% overhead is fa

4.029304 kHz
33.264 Watts

Inductance Calculator
Input Voltage
Frequency
Duty Cycle
Peak Inductor Current
Inductance
Estimated Power output

12
4
55
14

Volts
kHz
%
Amps

130.95 H
33.264 Watts

Output Power Calculator


Input Voltage
Inductor
Duty Cycle
Expected Efficiency
Frequency
Output Power
Peak Inductor Current

12
130
55
80
4

Volts
H
%
%
kHz

33.51 Watts
12.69 Amps

*Absolute Maximum, 10% overhead is fa

Voltage Regulator

*Absolute Maximum, 10% overhead is factored in later

Reference Voltage
Ra
Rb
Potentiometer
Max Voltage
Min Voltage

6
1000
12
10

V
k
k
k

506.00 V
278.73 V

*Absolute Maximum, 10% overhead is factored in later

High duty cycle, high voltage, low inductance and low frequency result in increased inductor current
Increased inductor current means more energy stored in the inductor, which is hopefully transferred to the load

erred to the load