Professional Documents
Culture Documents
Boiler Junction Box
Boiler Junction Box
Simplified wiring.
Cable clamps.
APPLICATION
The Boiler Junction Box allows simplified wiring and IEE
compliance when connecting mains, boiler and pump to the
system. When the mains, boiler and pump are located a
considerable distance from the Base Unit, it allows either two
twin and earth cables or a single three core and earth cable to
be run from the boiler junction box to the Base Unit. This reduces
the number of cable runs required and also the potential for
errors to be introduced in the system wiring.
1.5
Specification
Ordering Specification
42009699-001
Boiler Junction Box
42005749-001
Mini trunking sub base adaptor complete
with sub base to Boiler Junction Box and
fixing screws.
Dimensions
A
101
B
30
C
170
D
106
E
93
F
185
: 17
: 2 x 1.5mm2
: 10 amp 230V 50Hz
: 5 amp 230V 50Hz
: 4 x 2.5mm2 twin and E
: (max) per clamp (2 off)
Ambient Temperature Rating : 10C to 90C
Fixing
: 3 fixing holes in base for
: No. 8 woodscrews
MINI TRUNKING SUB BASE ADAPTOR
Mini Trunking Breakouts
: 13 breakouts distributed around the four
: sides of the adaptor
Cable Clamp Capacity
: 4 x 2.5mm2 twin and E (max) per clamp
: (2 off) from Boiler Junction Box
Fixing
: 3 fixing holes in base for No. 8 woodscrews.
: 3 off 4BA screws provided to fit adaptor to
: Boiler Junction Box
EC Directive
: Conforms to 89/336/EEC