Download as pdf
Download as pdf
You are on page 1of 6
niversity School of Engineering & Technology Capstone Power and Control Design Week 6 Tutorial Question 1 ‘A.10 MVA load is installed and couples to a MV bus where the fault level is 1OOOMVA. (a] Would this load pass a stage 1 flicker assessment? (b) Using the planning levels given in lectures for MV systems compute the short and long term MV globally allowable flicker levels assuming a HV->MV transmission coefficient of 0.7. (c) Assuming coincidence factors of 0.3 determine the maximum allowable short and long term flicker levels for this load. (4) Repeat (c) for a 50 MVA load. (e) With both the 5 MVA and the 50 MVA loads connected compute the allowable flicker available for subsequently connected loads ( note the cubic summation law) (f) Compute the maximum load for part (e) that could be connected without failing a stage 2 assessment. Question 2 (a) Using Excel compute the MV global contribution for all harmonics up to 25 assuming a transmission coefficient from HV to MV of 1.0 (b) Using this information compute the harmonic emission limits for 750 kVa MV load fed from HV via a 40 MVA transformer Question 3 A salient pole generator with a parameters given on the next page has a EXACA type exciter and a TGOV1 governor installed. It is connected to an infinite bus via a transformer and line each with 5% reactances. Assume the generator supplies 1 per unit power to the infinite bus. (a) Construct this system in PSSE and perform a load flow. (b) Construct the dyr file and simulate a bolted three phase fault on the HV side of the transformer. {c) Repeat (b) with the exciter disabled (d) Repeat (b) with the governor disabled (c) Determine the critical clearing time (f) Perform an exciter response test for this system (g) Perform a governor response test for this system SIEMENS Generator Model Data Sheets Psst 33.5 GENSAE PSS®E Model Library ee een eens 1.20 GENSAE Salient Pole Generator Model (Exponential Saturation on Both Axes) ‘This model is located at system hone #____ Bus, \ # : a as rd an 4 my LISORCE, sours Curent and STATES starting with Vr POETS) GENSAE | ETERM terminal Voltage ‘The See is. foreach of Bus ZSORCE for this machine is +] ANGLES angle ‘on the above MBASE, CoNe | # | Value Deserintion J Tao (#0) (sec) Jet OO LT "do (70) (sec) Try 0:0. 21] 7" O) (sec) He (-0 |Finenia ie @-0 |D, Speed damping a6 2.25% i 1-47 [a 7 0.21% a8 O16 |Re=*a if #9 Pa J#10 Ot {80.0 it 0:6 (S02) Note: Xq, Xq, X's, X°d, X"q, Xi, H, and D are in pu, machine MVA base. X’q must be equal to X"g. ‘SiaTes [| # Description K Ey KH va Kee vkd KS A speed (pu) Kea ‘Angie (radians) a IBUS, "GENSAE’, ID, CON() to CONW#11) ‘All material contained inthis documentation i proprietary to Siemens industy, ne. Siemens Power Technologies Inernational 1468 SIEMENS pss 33.5 ‘Turbine-Governor Model Data Sheets PSS®E Model Library TGOVI ee ea 7.21 TGOV1 Steam Turbine-Governor This model s located at system bus # 1Bus, Machine identifier “ 10, an oo This model uses CONs starting with 4 SPEED | cov: | PMECH, ‘and STATES starting with « kK ‘and VAR * L cons [_#_| Value Description J O05 |R v4 0-4 [1 9) (ee) Be LS |viwax" 3 0.00 Monn 4 OY [Te (sec? a 1-2 [ts 0) (sec) m7 0-0 [oF 1” Vax. Van, Dt and Rare in per unit on generator MVA base. ; ‘T2lTg = high-pressure fraction, reheate ime constant. ‘stares | # Description K Valve opening ie Turbine power vars | # | Description T [Reference IBUS, ‘TGOV1’, ID, CON(J) to CON(#6) 1 Allmaterial contained inthis ocumenttion is proprietary to Siemens Industy, Inc, Siemens Power Technologies Intemational 7-61 SIEMENS ‘Turbine-Governor Model Data Sheets pss 33.5 T6OVt PSS®E Model Library PMECH ‘All material contained in this documentation is propristery to Siemens industry, Inc, Siemens Power Technologies International. 782 SIEMENS Excitation System Model Data Sheets pss®e 33.5 EXAC4 PSS®E Model Library —— 6.28 EXAC4 IEEE Type AC4 Excitation System This model is located at system bus IBus, Machine identifier +, This model uses CONs starting with @ J, a and STATEs starting with K. = cons | # | Value Description Z Gos [TR a 10 _|Vimax we =10 [Vim Es 9-0000i|TC 4 0-00001 |Te (see) #5 20 |Ka 6 0.02 [TA #7 | [o_|vrmax He =10 [VaMIN 8 oO [Ke states | # Description K Vmeasvres a Lead lag 2 Ve IBUS, 'EXACA’, ID, CON(J) to CON(J+8) / VReF Vs ] _ viwax rau Koteo |. + teste] [ka 5 |_| o> Teste) ert *\ieste| *|Testal 7? Vian VRMIN-Kc Heo \VS= VOTHSG + VUEL + VOEL. All material contained in this documentation is proprietary to Siemens Industry, In. Siemens Power Technologies international 6-86

You might also like