Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Calculation of Combined Margin Emission Factor

Simple operating margin CO2 emisison factor

EFgrid,CM,y = EFEL,j,y
EFgrid,OMsimple,y
2006-07
1.01

NEWNE Regional Grid


Build margin CO2 emisison factor

EFgrid,BM,y

NEWNE Reginal Grid


Combined Margin Emission Factor

EFgrid,CM,y

Steam Enthalpy Calculation


Parameter
Steam Flow
Steam Pressure
Steam temperature
Feed water temperature
Enthalpy at 16.00 kg/cm2 & 230 0C
Enthalpy of feed water
Enthalpy of steam per kg
Thermal energy generated
Thermal energy generated
Thermal energy generated

Historical data
Historical data
Historical data
Historical data
Calculated from steam table
Calculated from steam table
Calculated
Calculated
Calculated
Calculated

Calculation for thermal capacity of boilers in Project scenario


Steam Flow

Technical specifications

Assuming 860 kCal = 1 kW

Calculated

tCO/MWh
tCO/MWh
2007-08
1

2008-09
1.01
1.01

tCO/MWh
2008-09
0.68
tCO/MWh

Unit

0.843333

kg/year
Kg/cm(g)
0
C
0
C
kcal/kg

Value
100717803.00
16.00
230.00
105.00
684.25

kcal/kg
kcal/kg
kcal/year
TJ/year
kcal/hour

109.89
574.36
57848277331.08
242.15
6603684.63

kg/hour
kCal/hr
kJ/hr
KJ/s
kWthermal
MWth

28000.00
15103200.00
63221995.20
17561.67
17561.67
17.56

You might also like