The SENSY's load cells 5100-5105 are perfectly designed to the following applications :
5100 - 5105 : (10) - (15) - 20 - 30 - 50 - (75) - 100 - (150) - 200 - 300 - 500 kN
(0.75) - 1 - 1,5 - 2 - 3 - 5 - 7.5 - 10 - 15 - 20 - 30 MN
Specifications
0.25
Accuracy class
0.1
0.05
0.03
1000 d
2000 d
3000 d
Combined error
< 0.25
< 0.10
< 0.05
< 0.03
% F.S.
Linearity error
< 0.25
< 0.10
< 0.04
< 0.025
% F.S.
Repeatability error
< 0.1
< 0.03
< 0.02
< 0.015
% F.S.
< 0.1
< 0.06
< 0.04
< 0.025
% F.S.
< 0.025
< 0.015
< 0.01
< 0.0075
% F.S.
Reference temperature
23
23
23
23
-10...+45
-10...+45
-10...+45
-10...+45
-30...+70
-30...+70
-30...+70
-30...+70
-50...+85
-50...+85
-50...+85
-50...+85
< 0.05
< 0.05
< 0.035
< 0.015
% F.S./10C
< 0.035
< 0.035
< 0.03
< 0.023
% F.S./10C
Zero balance
0.02
0.02
0.02
0.02
mV/V
Sensitivity tolerance
< 0.3
< 0.3
< 0.3
< 0.2
Input resistance
352 2
352 2
352 2
352 2
Ohm
Output resistance
352 2
352 2
352 2
352 2
Ohm
> 5000
> 5000
> 5000
> 5000
Megaohm
10
10
10
10
VDC
3..12
3..12
3..12
3..12
VDC