DESIGN OF ISOLATED FOOTING (BASED ON EBCS 7 AND 2)

INPUT DATA
[in kN-m units,others in their standard]
Material Quality and Workmanship
Concrete Grade

Steel Grade

C25

Allowable Stress

Class of Works

S300

Select bar diameter

300

Design Loads

I
12

Footing with predetermined

Column Dimensions
side x

0.25

side y

0.3

Axial Load

890

value(s) of

Moment X-X

0.2

ratio X:Y

Moment Y-Y

0.7

ratio X:Y
1
0.21

OUTPUTS
[in kN-m units, unless it is indicated]
PartialsafetyfactorandDesignConstants
C
fck
fcd
fctd
Concrete
Steel

1.50
S

20.00
fyk
300

1.15

11.33
fyd
260.87

Design
eccentricities
ex= 0.001
ey= 0.000

1.04
min
0.002

PROPORTIONING

FOOTINGDIMENSIONS
suited for construction
side X
side Y
1.75
1.75

CONTACTEARTHPRESSUREDISTRIBUTION
(At the four corners)

291.62

291.17

290.05

289.60

STRUCTURAL DESIGN
EFFECTIVEDEPTHREQUIREDFOR:

(a) punching shear


(b) wide beam shear

,deff=
,deff=

0.320
0.381

Observation:thecriticaldeff=

0.381

FOOTINGTHICKNESS
(rounded to multipe of 50)
Hence,modifiedcriticaldeff

= 450mm
= 0.382

MAXIMUMMOMENTSandarea of reinforcement
Mmax
Mdy= 143.31
Mdx= 133.73

Asreq (mm2)
1475.60
1374.53

No. bar
1412
1312

Asprov(mm2)
1582.56
1469.52

spacing(c/c)
130
140

Result: provide 12 with spacing of 130mm(c/c) in the direction of

provide 12 with spacing of 140mm(c/c) in the direction of