INPUT DATA
[in kN-m units,others in their standard]
Material Quality and Workmanship
Concrete Grade
Steel Grade
C25
Allowable Stress
Class of Works
S300
300
Design Loads
I
12
Column Dimensions
side x
0.25
side y
0.3
Axial Load
890
value(s) of
Moment X-X
0.2
ratio X:Y
Moment Y-Y
0.7
ratio X:Y
1
0.21
OUTPUTS
[in kN-m units, unless it is indicated]
PartialsafetyfactorandDesignConstants
C
fck
fcd
fctd
Concrete
Steel
1.50
S
20.00
fyk
300
1.15
11.33
fyd
260.87
Design
eccentricities
ex= 0.001
ey= 0.000
1.04
min
0.002
PROPORTIONING
FOOTINGDIMENSIONS
suited for construction
side X
side Y
1.75
1.75
CONTACTEARTHPRESSUREDISTRIBUTION
(At the four corners)
291.62
291.17
290.05
289.60
STRUCTURAL DESIGN
EFFECTIVEDEPTHREQUIREDFOR:
,deff=
,deff=
0.320
0.381
Observation:thecriticaldeff=
0.381
FOOTINGTHICKNESS
(rounded to multipe of 50)
Hence,modifiedcriticaldeff
= 450mm
= 0.382
MAXIMUMMOMENTSandarea of reinforcement
Mmax
Mdy= 143.31
Mdx= 133.73
Asreq (mm2)
1475.60
1374.53
No. bar
1412
1312
Asprov(mm2)
1582.56
1469.52
spacing(c/c)
130
140