Professional Documents
Culture Documents
Submarine Cables. O&M
Submarine Cables. O&M
Submarine Cables. O&M
Telefonica Global
Solutions
05.01.2014
2. Preventive maintenance
3. Corrective maintenance
4. Future challenges
SAm-1
SAm-1 in Telefonica
2014: 5 Tbps
01
01
AVENIDA 58
(Sand Street)
C7
C6
To Sta. Teresita
C3
TELEFONICA TERRESTRIAL CABLE
AVENIDA 7
(Paved)
302 m
C2
FREE
F.O.
POWER
GROUND
LAND CABLE
C1
AP
CAMARA PASO
(ENTERRADA)
CALLE 2
To Las Toninas
342 m
371 m
CABLE STATION
C4
43 m
C5
BEACH
MANHOLE
CALLE 1
BMH
BEACH
Sam-1 upgrades
20000
18000
16000
Capacity (Gbps)
14000
12000
10000
8000
Upgrade
6000
Total Capacity*
4000
2000
0
40
40 80
80 160
160 320
2001
2005
2007
2008
640
1440
960
320
2009
2010
Year
2440
2160
3640
3040
600
2011
280
2012
600
2013
600
2014
Sam-1 upgrades
2005
2008
2010
First Upgrade
Third Upgrade
Fifth Upgrade
Nortel
March 2001
Sam-1 RFPA
Tyco 4x10 Gbps
2007
Second Upgrade
Tyco & Nortel
8x10 Gbps
160 Gbps
2009
Fourth Upgrade
Nortel & Infinera
640 Gbps
320 Gbps
2011
2012
2014*
Seventh Upgrade
Nineth Upgrade
2013
Eight Upgrade
600 Gbps
100G deployments
40G deployments
Direct Detection 10G deployments
2. Preventive maintenance
3. Corrective maintenance
4. Future challenges
Guatemala
Colombia
Per & Ecuador
Chile
Brasil
Florida & Puerto Rico
Argentina & Uruguay
Salvador
Brazil
Mncora
Per
2. Preventive maintenance
3. Corrective maintenance
4. Future challenges
Faults
APMA 2012-2016
Private maintenance agreement
3 ships : 1 based in Western Atlantic, 2 en Eastern Atlantic
TE Subcom in Curaao (Western)
ASN in Cape Verde and Calais (Eastern)
Lessons learnt
December 2010
Segment G (coast of Puerto Rico)
5500 m depth
Repair tasks
No Action
1Fault information detailed SMNDAM-4078614 and effective from
10:24UTC, 04/12/10
2Await for depot personnel
3Commence loading of Sam 1 cable and kits
4Vessel departs - FAOP to cable ground
5Awaiting back capacity traffic restoration
6Set up in DP and prepare for DG#1
7Cutting drive DG#1at approx fault location
Commence
Duration Complete
(Hours)
04/12/2010 6:24
04/12/2010 6:24
04/12/2010 18:55
05/12/2010 19:30
07/12/2010 23:30
09/12/2010 16:30
09/12/2010 17:30
12,5
24,6
52,0
41,0
1,0
10,4
10/12/2010 3:55
61,1
12/12/2010 17:01
13/12/2010 2:01
16/12/2010 19:01
9,0
89,0
21,0
17/12/2010 16:01
19/12/2010 6:01
19/12/2010 8:31
19/12/2010 20:31
19/12/2010 22:43
20/12/2010 12:55
20/12/2010 18:55
20/12/2010 20:55
21/12/2010 13:55
38,0
2,5
12,0
2,2
14,2
6,0
2,0
17,0
2,0
21/12/2010 15:55
22/12/2010 0:55
22/12/2010 12:55
9,0
12,0
12,0
23/12/2010 0:55
23/12/2010 14:55
24/12/2010 14:55
14,0
24,0
32,0
25/12/2010 22:55
28/12/2010 2:55
29/12/2010 0:25
52,0
21,5
0,0
22
TITULAR PRIMERO
19/12/2010 6:01
19/12/2010 8:31
19/12/2010 20:31
19/12/2010 22:43
20/12/2010 12:55
20/12/2010 18:55
20/12/2010 20:55
21/12/2010 13:55
21/12/2010 15:55Activacin plan B
22/12/2010 0:55
22/12/2010
12:55OTDR Monitoring during payout
TITULAR PRIMERO
23/12/2010 0:55
23/12/2010 14:55
24/12/2010 14:55Terminal Testing
25/12/2010 22:55With BRH. Vessel released from cable ground. Hand
back power control. Including 24hrs terminal
testing prior to activating BRH
28/12/2010 2:55KPI @ 12 knots
29/12/2010 0:25
29/12/2010 0:25
Spares loading
TITULAR PRIMERO
TITULAR PRIMERO
23
ROV operations
Representatives onboard
TITULAR PRIMERO
TITULAR PRIMERO
27
Gridless WDM being tested to allow smaller carrier spacing and increase
systems capacity
200 Gbps wavelengths being tested
Unisur