2N4401 10k MLT666BX 10 47 7k5: T3A T2A

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MLT666B-HL2

MLT666B-HL2

B3SR60

400V
VWICB

510k
T5A H250V

2.2

0u22
275V
CNR D681K

1000
RJ13

RJ1

10

10

1000

470k

CY3
2200
470k

P76P72
K3683

510k

510k

10

39k

47

MLT666B

0.5

510k

L6562D

1.5

1.5

470k

1.5 1.5 1.5

10

100k
10k

10k

470
39k
300

10k

10

510k

22k

20k

2N4401

12k

MLT666BX
47

3k3

47

7k5

10

400V

T3A

T2A

1k

MLT666C

10k
10k

7k5

47

47

47

68k

4700
510
10

470

100

68k

200
MC0628R

2k

510k

2k

6N60C

6N60C
470k

470k

10

R32

470k

5k1

10

0.5

10k

560k

47k

2.2

10k

62734

1.5

10

68
VCC

10k

18k

6N60C

1k
2.2

2.2

2.2

10k

10 470

15k
MLT666C
4.7

15k

PQ6AP

12VA

PH5VT

12VB

18V

5VSB
3k3
P1
PC817

100
47

100

18V
20k

PC817
PC817
1k5

1k5

560
2k

STP20150CFP
27k

10k
10k

510

T1
MLT666BX

STPS2045CFP

1k

100

18V

20
20

TL431AC

10k

4k3 k3 4

4kk334

10k

100kk1 100kk 1

4kk33

T2C

3k3

56k

4k7

T2
MLT666C

12VA
12VB

RJ8
20

T2D

5VSB

1k
3k3

10k

STP20150CFP

100
PC817
TL431AC

10k

2200

1000

20

220k

T3C

T3
MLT666C

T3D

20

RJ9
20

20

4k3

4k3

Order Code.. KT33

POWER SUPPLY REPAIR KIT


POWER BOARD..MLT666 (VERSION A & B)

For MLT666
Fault
Sympton: Dead, Mains Fuse Blown

Circuit Reference

Description

F1
Q8
Q9
IC2
Z4
Q5
Q6
R72
R49
R52
R71
Q2
D3
Z2
IC5
D2
R21B
R21C
R21D
R21E
R21F
R43
R44
R41
R42
R74

T5A
STP6NK60
STP6NK60
MC0628
1N4739
BC858
BC858
10 ohm
100 ohm
100 ohm
10 ohm
18N50
5L60
1N4739
L6562D
1N5406
1R5
1R5
1R5
1R5
1R5
1R5
2R2 or 1R5
470R
470R
0R47

We recommend all kits are fitted by qualified engineers


We accept no responsibility for loss, injury or damage caused by your use of this kit as a successful repair
depends on your own skill and fault finding ability.

PRODUCED WITH PERMISSION FOR CHARLES HYDE & SON

You might also like