LAB REPORT

Unit ID

Biodiesel (FAME)

Component

FAME (as biodiesel fuel)

Current sample number

1700657
page 1 of 1

Sample from:
Oil brand name:
Oil quantity in system:

OELCHECK GmbH Postfach 1116 83094 Brannenburg

Tank
Biodiesel DIN EN 14214
28000

Example report
Analysis scope: Fuel Kit 3KB

Diagnosis for the current laboratory values


The water content is within the normal range. The measured results are typical for FAME (RME/biodiesel) fuel according to DIN EN
14214. There are no abnormal values visible. To determine whether all other requirements of this standard (e.g. cetane number, iodine
number) are compliant, additional tests would need to be undertaken.
Dipl.-Ing. Stefan Mitterer

Sample Rating

normal
ANALYSIS RESULTS
LAB NUMBER

Current sample

1700657

SAMPLE RATING
28.04.2015
23.04.2015
-

Date tested
Date of sample taken
Date of last oil change
Top-up since change
Operating time since change
Total operating time
Oil changed

WEAR
Iron
Chrome
Tin
Aluminum
Nickel
Copper
Lead
Molybdenum
PQ index

Fe
Cr
Sn
Al
Ni
Cu
Pb
Mo
-

mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg

0
0
0
0
0
0
0
0
< 25

Si
K
Na
ppm

mg/kg
mg/kg
mg/kg

0
0
0
388

CONTAMINATION
Silicon
Potassium
Sodium
Water K. F.

OIL CONDITION
Viscosity at 40C

4.15

mm/s

ADDITIVES
Calcium
Magnesium
Boron
Zinc
Phosphorus
Barium
Sulphur

Ca
Mg
B
Zn
P
Ba
S

mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg

0
0
0
0
0
0
< 10

ADDITIONAL TESTS
Density 15C
Flash point CC

kg/m
C

Description of standards and test methods: www.oelcheck.de

882
180

Previous samples