Provide # 16 335 C/C Along X Direction

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Footing ID:

S.B.C
Concrete grade, fck
Steel Strength, fy

F1
250
30
460

kN / m
N / mm2
N / mm2

Column size, Cx
Column size, Cy

200
400

mm
mm

Unfactored Loads(DL+%LL):
P
188.0
Fx
0.0
Fz
0.0
Mxx (My)
0.0
Mzz (Mx)
0.0
Load Factor:
1.5

1.2

Depth of Footing :
Footing Depth =
Eff. depth,d =

0.5
0.425

195.8
195.8

kN / m2
2
kN / m

Check for 2W shear:


tv =
0.106
tc =
1.37

N/mm2
2
N/mm

Pmax =
Pmin =

1.44 m

Area Provided =

L1Y =

0.4

L1X =

kN
kN
kN
kN-m
kN-m

(considering 5% extra for self weight)


Area required = 188 x 1.1 /250 =
Footing size provided:

LX = 1.2

L1X =

LY =

0.5

1.2

0.5
L1Y =

0.4

0.83

1.2

(m)

Additional Moments: ( Due to Fx and Fy)


MX1=FX x D =
0 kN-m
MY1=FZ x D =

OK

Final Loads :
P
=
MX
=
MY
=

m
m

0 kN-m

282.0 ( kN )
0.0 ( kN m )
0.0 ( kN m )

OK
OK

345
>

0.106

345

OK

Design for Flexure:


Moment in X-direction =

196
37
218
600

Ast in X direction
Provide #

16

335

Moment in Y-direction =
Kx =

196

x1.5 x 0.5x0.5 / 2
kN-m/m
2
mm /m
2
mm /m
C/C along X direction

600
(5 # 16)

x 1.5 x 0.4x0.4 / 2

24 kN-m/m
Ky =
0.130

0.203
0.05

Ast inY direction


Provide #

16

2
139 mm /m
2
600 mm /m
335
C/C along Y direction

(5 # 16)

Check for 1W shear:


tv

tv

tc

1.5 x Pmax x L1 / d
0.052

N/mm2

0.18

N/mm2

>

0.052

OK

Designtree Consultants Pvt. Ltd.


Page 1

You might also like