Typical Details for Temporary

Access for Gate A & E


Provide 4m turning radius

Provide 20mm thk


steel plate to protect
existing drain.
Top up with lean
concrete on steel
plate and flushed
with surrounding
level

Project
Jln Ulu Seletar
Part of Structure
Steel Plate
Calc. by
Date
Chckd by
LZL
Oct 2013
KWP
Ref.

Date
Oct 2013

Calculations

Job Ref.
2013-034
Sheet no./rev.
1
App'd by Date
LSW
Oct 2013
Output

Member Properties
; Thickness of steelplate;

t = 20 mm;

; Design strength of Steel Plate;

qply = 265 N/mm ;

Width of drain = 1m

Design Forces
Assumed vehicular live load of 20 kN/m

Design Bending Moment = (1.6 x 20 kN/m x 1m x 1m) / 4 = 8 kNm


2

Load Transfer
; Design Bending Moment ;

M1 = 8 kNm;

; Moment capacity of Steel Plate;

Mcx1 = qply (t / 6) = 17.7 kNm/m;


2

Check Mcx1 > M1; Pass!