Air Pump Does Not Run

Normal Operation Sequence

10 - Plug the Stove In 21 Push the ON Button


11 LED's indicate P.O.S.T.
12 Burn Drive cycles three (3) times
13 Exhaust Fan Runs for 30 min then OFF
22 LED #1 Turns ON

20 - Startup Mode
21 Push ON Button & set Heat Level Burn Drive Motor cycles 3 times
22 #1 LED on 23, 24, 25, Feeder Wheel begins feeding Fuel
23 Number of LED's show Set Heat Level
24 Burn Drive cycles three (3) times
25 Feed Wheel Begins Feeding Fuel
26 After 1½ minutes, Air pump comes ON 26 Time delay of 1½ minutes to Air Pump turn on
27 After 15 seconds, the Igniters turn ON
28 Within 5 minutes, Smoke and than Flame
29 Igniters turn OFF after Flame is established
NO
30 After 15 seconds the Air Pump goes OFF Air Pumps Runs Unplug Air Pump
31 Stove Ramps to Heat Level 4 from Mother Board
32 After 20 minute Startup Period, stove ramps
up or down to User Set Heat Level

Check for broken wires


40 - Normal Run mode or Bad Connections
41 Stove runs at User SET HEAT Level
42 Ash Dump per Heat Level
43 Stove ramps to Heat Level 4 during the Ash
Dump process Check Air Pump for
continuity
44 Stove runs until User turns the Stove OFF
YES YES NO

50 - Normal Shut Down Mode

51 Push the OFF Button


52 Feeder Wheel Stops feeding Fuel
53 1st 10 minutes Exhaust Fan Increases speed
54 Next 20 minutes Exh. Fan runs at 50% speed
55 After 30 min. total, Ash Dump, Stove is OFF
41, 42, 43, 44

Run Stove Replace the Mother Board Replace the Air Pump