The LED Indications in the table reflect the different states that can be observed in
the System Module.
In cases where un-commissioned modules are installed or attached to other
un-commissioned modules then the LED colour may not match the meaning as
described in the table,for the corresponding 'commissioned' case, i.e. a blinking red
LED in an un-commissioned module does not mean that the module is faulty.
Always use the active alarms and alarm history with the LED status to identify BTS
faults.
Led Colour
Meaning
Module State
Detailed States
Stable green
Module is fully
functional.
Commissioned
BTS_OM SW
state is
supervisory and
no minor, major
or critical alarms
are active on
BCF or TRE
object.
Blinking green
Module is
downloading
software.
Commissioned
BTS_OM SW
state is
configuring and
the sub-state is
Software loading.
- or BTS_OM SW
state is
supervisory and
SW is being
downloading in
the background.
- or -
BTS_OM SW is
in local mode
(no BSC
connection).
Stable yellow
Site is not
carrying traffic.
Commissioned
BTS_OM SW
state is
configuring and
the sub-state is
Wait for LAPD
establishment
but LAPD on
OMUSIG is not
established and
alarm is active
on TRE object.
- or System module
(BCF object) is
blocked from
BTS Manager.
- or System Module
(BCF object) is
locked from
BSC.
Blinking yellow
Module is
starting up.
Commissioned
System Module
SW is booting.
- or BTS_OM SW
state is
initialization or
configuring
including the
sub-states: Auto
detection,
Commissioning,
Wait for LAPD
establishment
and LAPD on
OMUSIG is
established.
- or BTS_OM SW is
in local mode
(no BSC
connection).
Stable red
Module is not
functioning.
Commissioned
System Module
SW is not
running.
- or Alarm is active
with class
critical (***) on
BCF/TRE.
- or BCF reset has
been executed.
Blinking red
Module has a
major fault but
is still partially
functioning.
Commissioned
Alarm is active
with class major
(**) but System
Module (BCF
and TRE) is still
enabled.
Module is being
highlighted for
location from
BTS Manager.
Commissioned
BTS Manager
has requested
indication for
System Module
and timer is still
running.
BCF is
Commissioned
BCF is
Highlighted
colours
Periodic
green/yellow
commissioning
commissioning
Periodic
red/yellow
Waiting for
OMU signal
(with PWE
mode)
Commissioned
Waiting for
OMU signal
(with PWE
mode)
Periodic
red/red/red/yellow
Blocking fault
at
commissioning
(BCF/TRS
critical alarm)
Commissioned
Blocking fault at
commissioning
(BCF/TRS
critical alarm)
Blinking yellow
and green
Auto-connection
has been
started at BTS
end
Uncommissioned
Due to
auto-connection
feature, BTS
shows blinking
yellow and green
while in
un-commissioned
state to indicate
user that
auto-connection
has been started
at BTS end.