BOSCH EP test values diesel fuel-injection equipment

Test date
Customer ID No.

4/25/2013 Time: 9:10:49 AM

Job. no.: ____________________


Serial no.: ____________________

PUMP AND CUSTOMER DATA


PUMP DATA
Edition
Part no.
Pump designation

29.05.02
0 460 426 273
VE6/12F1200R738

CUSTOMER DATA
Customer
Engine
Power

MAN
D 0826LF18/LFL10
162 kW

TEST PREREQUISITES
CAT Designation
Test oil
Calibrating oil return temp.
Overflow restriction
Inlet press.
Test nozzle holder assembly
Opening pressure
Test pressure line
Outside diameter
x Inside diameter
x Length
Shutoff solenoid
Shutoff
INJECTION-PUMP TEST SPECIFICATIONS
OVERFLOW
CAT Designation
D Temperature stabilization speed
D Initial temperature
D Measurement temperature
D Temperature stabilization speed
D Initial temperature
D Measurement temperature
D Temperature stabilization speed
D Initial temperature
D Measurement temperature

Unit

mm
mm
mm
V
V

Set value
ISO 4113
45
0.75
0.35
1 688 901 110
250.00
1 680 750 017
6.00
2.00
840
24
0

Unit
1/min
C
C
1/min
C
C
1/min
C
C

Set value
2000
48
46
100
42
44
2000
48
46

min.

max.

Actual values
2000
48
46
100
42
44
2000
48
46

OT

Set value
3.7
KOT
1.5

min.
3.6
3
1.4

max.
3.8
3
1.6

Actual values

OT

1.0
A

0.98

1.02

38.9
47.0

36.9
44.4

40.9
49.6

C
mm
bar
bar

SETTINGS/TEST SPECIFICATONS
ASSEMBLY AND ADJUSTMENT DIMENSIONS
CAT Designation
Unit
Dimension K
mm
Dimension KF
mm
MS1 dimension
mm
POMPE/ENGINE ASSIGNMENT
Plunger stroke
mm
S
S
Outlet
SETTING CONTROL LEVER POSITION
Control lever spacing YA
mm
Control lever spacing YB
mm
CAT = Category (D = Default, S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)

min.

max.

44.0

46.0

0.30

0.40

247.00

253.00

Actual values

OT

You might also like