Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

+1.

5V
SILVER OXIDE

#76 CELL

10uF
C1

TOUCH INPUT
C2

EARTH GND

0.01
SENSITIVITY = 0 - 150pF
+1.5V

100uS

CLK

SAMPLE

CW

VSS
7

R6

75K
R1

4.7M
R2

13
PR CLR
D

NORMALLY CLOSED

Q2

ZVNL110

NORMALLY OPEN

B
11

47pF
C5

A
CLR

12

R6

_ 6
Q

74HCT74

10K

470K

10

C7

500K
R5
SENSITIVITY ADJ

VDD PR

0.001uF

150K
R4

14

+1.5V

CK

_
Q

Q3
100mA MAX

ZVNL110

74HCT74

47pF
C6

WHEN NO TOUCH, DATA IS HIGH BEFORE CLK

1
0.001
C3

WHEN TOUCHED, DATA LAGS CLK, OUTPUT CHANGES STATE

Q1
0.01
C4

ZVNL110
AVERAGE CURRENT = 3uA
100uS SAMPLE TIME

20 Hz PULSE GENERATOR

20 SAMPLES PER SECOND


APPROX. 5 YEARS OPERATION

DRAWN BY: DAVE JOHNSON

TOUCH ACTIVATED SWITCH


MOMENTARY OPERATION

DAVID JOHNSON AND ASSOCIATES


TOUCH ACTIVATED SWITCH
MOMENTARY OPERATION
1.5V BATTERY POWERED
Size

Date:

Document Number

Rev

MOM1V1.DSN

Friday, January 18, 2002

Sheet

of

You might also like