Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

CLIENT: GAS AUTHORITY OF INDIA LTD. Doc. No.

:
CONSULTANT: ENGINEERS INDIA LTD. PLL/PPL/VSPL/P28
CONTRACTOR: PUNJ LLOYD LTD. Rev. No. : 0
Punj Lloyd Ltd. PROJECT: VIZAG-SECUNDERABAD PIPE LINE PROJECT APPENDIX-1

INSPECTION & TEST PLAN FOR ARC STRIKE REPAIR

Document To
Inspection Verification
S# Activities be Submitted Remarks
by PLL by EIL
by PLL

1 Approval of Arc Strike Procedure W W

2 Cleaning/Grinding W RM

3 Metal thickness check W W Appendix-2

4 PT/MT Test W W Appendix-2

5 UT If Required W R Appendix-2

6 RT If Required W W Appendix-2

LEGENDS:

"A" ACCEPTANCE
"W" WITNESS INSPECTION
"RM" RANDOM INSPECTION
"R" REVIEW OF DOCUMENTS

0 10.05.02 For Implementation

Rev.
Date Rev. Desc. Prep. By PLL App. By' PLL App. By' EIL