DESIGN REPORT FOR

E-305

FEED PUMP COOLER

CLIENT: SIS
CLIENT REFERENCE: SED-1405
GUIDELINE REFERENCE: SIS 010

Rev No By Date Checked Date

Rev no Reason Pages Affected

/opt/scribd/conversion/tmp/scratch4539/39676241.doc
0 First issue All
1
2
3
4

INDEX

Design data 3
Report, notes and assumptions 3
SANS 347 Vessel Category 4
Gasket information 6
Code calculations 7
DESIGN DATA
Shell Tube
Design pressure 2500 kPa 2500 kPa
Design temperature 90 ºC 230 ºC
MDMT -45 ºC 0 ºC
Joint efficiency 1 1
Corrosion allowance 1.6 mm 2.5 mm
Shop test pressure (Btm) 3250 kPa 3250 kPa
Field test pressure (Btm) 3125 kPa 3125 kPa

Design code: ASME VIII Div 1, 2007 Add 2009

Supplementary specifications: N/A

REPORT, NOTES AND ASSUMPTIONS:


1. Calculations were not done for nozzles exempted under UG-36(c)(3)(a).
2. Values, m and y, for gasket used as provided by gasket supplier.
3. A thermal design is not available and the average fluid temperatures were used for the
MMT’s. Although doing this is not correct, it is considered acceptable as this is a
replacement for a heat exchanger which has a proven track record.
4. The saddle supports were checked using 2 ribs of 4mm each, instead or the 1 rib 8mm
thick used. The reported stresses are very low, so this can be accepted.
5. A schedule 30 weld cap, from SA-234 Gr WPB, may be used for the channel head.

You might also like