ETAP is the most comprehensive analysis platform for the

design, simulation, operation, and automation of generation,


distribution, and industrial power systems. ETAP is developed
under an established quality assurance program and is used
worldwide as a high impact software. ETAP is completely
localized in four languages with translated output reports in
six languages.

As a fully integrated enterprise solution, ETAP extends to a


Real-Time Intelligent Power Management System to monitor,
control, automate, simulate, and optimize the operation
of power systems.

Operation Technology, Inc.


(800) 477-ETAP • (949) 900-1000
Modular

Network Analysis Protective Devices Dynamics & Transients


Short Circuit - ANSI / IEEE Coordination & Selectivity Transient Stability
• ANSI / IEEE C37 Standards • AC & DC coordination • Complete synchronous & induction machine models
• IEEE 141 & 399 Standards • Graphically adjustable device settings • Comprehensive excitation system models
• UL 489 Standard • Extensive device library (verified & validated) • Comprehensive governor-turbine models
• Integrates with protective device coordination • Embedded short circuit analysis • Power System Stabilizer (PSS) models
• Automatic device evaluation for 3-phase, 1-phase, • Embedded motor acceleration analysis • GE, Westinghouse, & solar gas turbines
& panel systems • Integrated with one-line diagram • User-Defined Dynamic Models (UDM)
• Generator CB evaluation • Multi-axis time current curves • Unlimited sequence of events & actions
• Phase-shifting transformer • Comprehensive plot options • Typical & common disturbances & operations
• Load terminal short circuit calculation • Adjustable magnifying-glass zoom view • Automatic actions based on relay settings
• Time difference calculator • Short-time & long-time simulation
Short Circuit - IEC • Multi-function/level relays • Variable total simulation time & simulation step
• IEC 60909, 60282, 60781, & 60947 Standards • Device setting reports • 3-phase & line-to-ground fault actions
• Transient fault analysis - IEC 61363 Standard • Auto-sync check action
• Integrates with protective device coordination Sequence-of-Operation • Embedded Newton-Raphson initial load flow
• Automatic device evaluation for 3-phase, 1-phase, • View device operation sequence graphically • VFD dynamic model
& panel systems • Device failure & backup operation
• User-definable voltage c factor • Sequence viewer Generator Start-Up
• Load terminal short circuit calculation • Normalized (shifted) curves • Cold-state generator starting
• Current summation • Load generators prior to synchronous speed
Arc Flash • Relay actions (27, 49, 50, 51, 51V, 59, 67, 79, 87) • Frequency-dependent machine models
• IEEE 1584 2002 & 2004 Standards • Frequency-dependent network models
• NFPA 70E 2000, 2004, & 2009 Standards • An expansion to the Transient Stability module
• CSA Z462 2008 Standard • Utilizes user-defined dynamic models
• ASTM D 120-02a Standard
• OSHA 29 CFR 1910 Standard Wind Turbine Generator
• NEC 110.6 Standard • Model unlimited wind turbine generators
• NESC Standard • Detailed modeling of turbine dynamics,
• Embedded short circuit calculation aerodynamics, & power coefficients
• Embedded device coordination • DFIG with pitch & converter controller
• Cubic box & open air • Simulate wind disturbance like ramp & gust
• Report & label generation • Individual or zone-based disturbances
• Maintenance mode switch Relay Test Set Interface • WECC wind turbine models
• Relay actions (49, 50, 51, 67, 79, 87) • Interfaces with testing & maintenance database
• Load terminal faults • Export short circuit data User-Defined Dynamic Model
• Panels & single-phase systems • Export protective relay settings • Library of pre-built models
• Multi-report result analyzer • Plot device steady-state response • Customize existing UDM models
• Work permits & data sheets • Compare relay response with OEM data • Wide variety of blocks for building models
• Display relay actual transient response • Import Simulink® models
Load Flow • Analyze relay false trips & mis-operation • Various model testing methods
• Power flow • Export to COMTRADE format • Real-time compiling & linking of model
• Demand load • Full graphic builder
• Voltage drop
• Power factor correction Parameter Estimation
• Automatic device evaluation • Induction machine equivalent circuits
• Automatic temperature correction • Single-cage models
• 2W & 3W transformer LTC/regulator actions • Rotor deep-bar effects
• Real & reactive power losses
• Extensive violation alerts
• Multi-report result analyzer
ETAP Quality Assurance
Motor Acceleration OTI’s Quality Assurance program is specifically dedicated to meeting the requirements of:
• Dynamic motor acceleration

• Voltage flicker ISO 9001:2008 10002889 QM08
• Motor & load dynamic models
• Static motor starting
10 CFR 50 Appendix B ETAP is Verified and Validated (V&V) against field results,
real system measurements, established programs, and hand
• Multi-sequence starting 10 CFR 21 calculations in order to ensure its technical accuracy. Each
• Conventional & soft starting devices ANSI/ASME N45.2 release of ETAP undergoes a complete V&V process using
• Load & generation transitioning thousands of test cases for each and every calculation module
• Motor Operated Valve (MOV) simulation ASME NQA-1
and library data.
• Comprehensive alarm & warning ANSI/IEEE 730.1
CAN/CSA-Q396.1.2
ANSI N45.22
Intuitive

Cable Systems Distribution Systems Transmission Line


Underground Thermal Analysis Unbalanced Load Flow Line Constants
• Neher-McGrath Method • Unbalanced power flow • Conductor & ground wire libraries
• IEC 60287 Standard • Single-phase & unbalanced 3-phase modeling • Built-in configurations: horizontal, vertical, etc.
• Steady-state temperature • Unbalanced & nonlinear load modeling • General configuration: X, Y, & Z coordinates
• Ampacity optimization • Phase & sequence voltage, current, & power • Multi-line mutual coupling
• Automatic cable sizing • Voltage & current unbalance factors • Phase & sequence impedance matrix
• Transient temperature • Transmission line coupling • Transposed & un-transposed lines
• Automatic device evaluation • Short & long line models
Cable Pulling • Multiple layer soil model
• Integrated with one-line diagram cables Optimal Power Flow • Calculated or user-defined impedances
• Integrated with underground raceways cables • Solve multiple objectives simultaneously
• Pull multiple cables • Interior point method with barrier functions Line Ampacity
• Completely flexible pull geometry • Minimize power losses • Conductor ampacity vs. temperature
• Full ETAP cable library integration • Active power optimization • IEEE 738 1993 Standard
• Display 3-D pulling path geometry • Reactive power optimization • Determine maximum operating temperature
• Optimal dispatch for various loading conditions
Cable Ampacity • Calculate derated ampacity based on
• ICEA P-54-440 Standard Optimal Capacitor Placement temperature limit
• National Electrical Code® NFPA 70 • Optimal location & bank size • Consider weather, solar heat, &
• IEEE 399 Standard • Minimize installation & operation costs geographical location
• British 7671 Standard • Individual source or average energy cost
• Installation types include: • Voltage and/or power factor objectives Sag & Tension
-- U/G duct banks - Trenches • Minimum, maximum, & average loading • Sag/tension vs. temperature
-- U/G direct buried - Brackets • Branch capacity release & cost savings • Multiple spans between dead-end structures
-- Trays - Cleats • Review capacitor impact on the system • Level spans of unequal length
-- Ladders - Building voids • Capacitor control method • Solve spans of unequal length on different
-- A/G conduit - Trunking • Flexible constraints horizontal planes
-- Air drops - Embedded direct • Include effects of wind, temperature, & k factor
Reliability Assessment
Cable Sizing • System reliability HVDC Transmission Link
• Ampacity, voltage drop, & short circuit options • Customer oriented indices • Detailed rectifier & converter modeling
• Optimal & alternative sizes • Energy (cost) indices • Composite AC/DC & DC/AC systems
• Size based on actual loading and/or ratings • Sensitivity analysis • Built-in control schemes
• Single & double contingency • Inclusive transformer model
• Automatic harmonic spectrum calculation
Single-Phase Distribution • Easy-to-use integrated model
• ANSI & IEC Standards
• Load flow with graphical per phase display
• Voltage drop & power losses
• Voltage & current unbalance factors
• Automatic device duty evaluation & alerts

Ground Grid Systems Transformer


Finite Element Method MVA Sizing
• 3-D plots for step, touch, & absolute potentials • Sizing based on actual connected or operating load
• 3-D irregular configurations • ANSI & IEC standard types, classes, & ratings
• 3-D graphical interface views • Considers ambient temperature, altitude, load
• Rods & conductors in any direction Geographic Information System growth, & load factors
• Graphical display of over limits
(see DataX - CAD interface) GIS Map Tap Optimization
• View GIS maps in ETAP • ANSI/IEEE C57.116 Standard
IEEE 80 & 665 Standards • Display analysis results on GIS maps • Optimize unit transformer turns ratio
• Conductor & rod optimization • Synchronize GIS data to ETAP projects • Considers system voltage variation
• 3-D graphical interface views • Use graphical user interface for data mapping • Considers generation station auxiliary load
• Control modification & accept/reject actions • Generator reactive capacity vs. voltage plots
• Check consistency for data synchronization
• Utilize GIS map tools
Integrated

DC Systems Power Quality Data Exchange


Load Flow Harmonic Load Flow DataX
• IEEE 946 Standard • IEEE 519 Standard • Import & export data
• Integrated AC & DC systems • Automatic distortion evaluation (THD & IHD) • Data synchronization
• Embedded Newton-Raphson Method • Telephone influence factors (TIF & I*T) • Automatic one-line diagram generation
• Voltage drop • Automatic alerts of violations • Intelligent error checking
• Power losses • Harmonic sources library • Customizable data mapping
• Battery auto-activation • Embedded Newton-Raphson Method • Real-time data exchange
• Charger/UPS current limit • Embedded Accelerated Gauss-Seidel Method • RAW data / IEEE format
• Charger/UPS mode auto-switching
• DC converter modeling Frequency Scan SmartPlant® Electrical Interface
• Motor model auto-switching • User-definable frequency range • Bi-directional data exchange
• Identify resonance conditions • Map attributes of SPEL with ETAP elements
Short Circuit • User-customizable plots • Automatic one-line diagram generation
• IEEE 946 Standard • Synchronize SPEL data with ETAP projects
• Integrated AC & DC systems Harmonic Filters • Database mapping via graphic user interface
• Total bus & branch contribution fault currents • Filter design & sizing
• Fault current rising time • Single-tuned, high-pass, & band-pass filters Microsoft® Access & Excel Interface
• Battery modeling per ANSI/IEC Standard • Automatic filter overloading alert • Map Access & Excel worksheets to ETAP elements
• Charger modeling per ANSI/IEC Standard • Inter-harmonic filter modeling • Automatic one-line diagram generation
• Synchronize data to ETAP projects
Battery Discharge & Sizing • Perform consistency checks during data exchange
• IEEE 308, 485, & 946 Standards • Substitute missing information with ETAP defaults &
• Integrated AC, DC, & Control System Diagram library data
• Battery discharge simulation
• Battery sizing e-DPP® Interface
• Discharge via DC load flow or duty cycle summation • Map attributes of e-DPP to ETAP elements
• Voltage drop & loss consideration • Automatic one-line diagram generation
• Class 1E DC power & control system models • Synchronize e-DPP data to ETAP projects
• Simulation of control system with battery • Database mapping via graphic user interface
discharge voltage Panel Systems
• Duty cycle diversity factor CAD Interface
• Load model type per operating characteristics Panel ANSI & IEC • Export one-line diagrams in DXF format
• Battery duty cycle calculated from individual loads • Intelligent panel design & analysis • Import ground grid plans from AutoCAD®
• Options for battery & load duty cycle 1 min span • 3-phase (3W & 4W) panels
• Multiple user selected options for battery • 1-phase (2W & 3W) panels
characteristic interpolation • 1-phase (A, B, C, AB, BC, CA, & 3W) panels
• Multiple diversity & correction factors • ANSI & IEC Standards
• Battery sizing report in IEEE 485 Standard format • NEC load factors
• Plot battery capacity, voltage, & current • Load flow with graphical per phase display
• Plot bus voltage & load & branch flow • Automatic device duty evaluation & alerts
• Detailed battery library • Automatic updating of upstream panels
• Export panel schedules to Microsoft Excel
• Panel with internal & external feeders & loads

Control Systems
• Localized in four languages
DC Control Systems Diagram
• Simulation of operation sequence • Translated ouput reports in six languages
• Pickup & dropout voltage calculation
• Automatic alerts
• Burden & inrush modes
• Controlled contacts
• Integrated with battery discharge calculation
Base Package
ETAP Base Package is a set of core tools, embedded analysis modules, and engineering libraries that allow you to create,
configure, customize, and manage your system model. Core tools allow you to quickly and easily build 3-phase and 1-phase
AC and DC network one-line diagrams with unlimited buses and elements including detailed instrumentation and grounding
components. Base Package includes an intelligent one-line diagram, element editors, configuration manager, report manager,
project and study wizards, multi-dimensional database, theme manager, data exchange, and user access management.
Embedded analysis modules such as Cable Ampacity, Cable Sizing, and Transmission Line Constants provide integrated as well
as stand-alone capabilities to design, analyze, and size equipment. Engineering libraries provide complete verified and validated
data based on equipment manufacturer’s published data.

Embedded Analysis Modules System Elements Configuration Manager


• Unlimited AC (1-phase & 3-phase) & DC elements • Tabulate & control different status
• Unlimited buses: license dependent at run-time configurations
- Cable Ampacity
• Nested views (composite networks & MCC) • Compare source, load, & switching device
• Power grids, synchronous, & induction generators status
- Cable Sizing • MOV, synchronous, & induction motors • Flag changed data with checker capability
• Exciters, governors, & stabilizers • Copy, merge, export, import, & print
- Transmission Line Constants • Voltage & frequency dependent lumped loads
• Cables, lines, reactors, & impedance branches Multi-Dimensional Database
• 2W & 3W transformers with voltage regulators • Orthogonal multi-dimension database
• Remote connectors • Unlimited independent graphical views
• Harmonic filters & static var compensator • Unlimited status configurations
• Instrument transformers • Unlimited property revisions
• Protective devices & meters • Multiple loading & generation conditions
• Single & double throw switches
• Batteries, DC motors, loads, & branches
• Chargers, inverters, UPS, & DC converters
• ANSI, IEC, & user-defined elements with
rotation & multiple sizes

Libraries
• Comprehensive library: ANSI & IEC devices
• Verified & Validated (V&V) library data
One-Line Diagram • V&V locked data
• Built-in intelligent graphics • Add, copy, merge, & delete capabilities
• Network nesting • User-defined & controlled libraries
• Integrated 1-Phase, 3-Phase, & DC systems • User-access control & security
• Integrated AC, DC, & grounding systems • Edited-by & checked-by with date stamping
• Multiple generators & grid connections • User-controlled library merge
• Display results on one-line diagrams
Cable LV Circuit Breaker
• Customizable font types, styles, & colors
• Customizable display of ratings & results Cable Fire Protection Solid State Trip
• Real-time operating data
• Graphical display of equipment grounding Transmission Line Thermal Magnetic • Unlimited study solutions
• Graphical display of overstressed devices & alerts Motor Nameplate • ODBC – Microsoft® Access, SQL Server®, &
Electro-Magnetic
• Hide & show protective devices & grounding systems Oracle®
• Theme manager with status & kV color control Motor CKT Model Motor Circuit Protector
• Dumpster with unlimited cells: copy & paste
• One-line templates Motor Characteristics Model Overload Heater • User access security with password protection
• Propagation of nominal & rated voltage Motor Load Model Harmonic • Edited-by & checked-by with date stamping
• Propagation of phase connection • Merge project files via clipboard
Fuse Interruption Cost
• Automatic display of energized & de-energized
elements using dynamic continuity check Relay Reliability
Output Report Comparator
• Text box editor with dynamic link to properties Recloser Battery • Built-in output report comparison tool
• OLE object & ActiveX control integration
Electronic Controller Control Contact / Relay • Compare hundreds of study reports in one action
• Intelligent text box & hyperlink bookmarks
• Verify study results against benchmark reports
• Customizable output reports via Crystal Reports® HV Circuit Breaker Solenoid
• Batch printing with view-dependent printer settings
• User-friendly plotting
Network Simulation
• Unlimited buses (license dependent) & elements
Project Management Wizards • Looped & radial systems
• Manage studies with scenarios & macros • Automatic error checking
• Record scenarios based on study settings • User interface for all network analysis modules
• Macro controlled scenario execution • Customizable ETAP preference properties
• Multi-level user access management

Built-In Calculators
• MVA, MW, Mvar, kV, Amp, & PF conversion
• Motor nameplate & dynamic parameter data
• Generation nameplate
• Power grid short circuit impedances
• Motor & generation inertia
Report Manager
• Customizable output reports & plots Data Exchange
• Input, results, alerts, & summary reports • WMF / EMF / DXF / PDF exporting
• Reports via Crystal Reports viewer • Import RAW / IEEE / CSV files
• PDF, Microsoft Word, Access, & Excel reports • Export one-line diagrams in DXF format
• Element ID & text search capability • Import ground grid plans from AutoCAD®
• Multi-Language Report
Power Management System

An Intelligent Energy Management System for


Operators, Managers, & Engineers
ETAP Real-Time® is a suite of software tools that offers a fully integrated power management system.
Through continuous monitoring, simulation, and optimization of electrical, process, manufacturing,
and management systems, ETAP can maximize the entire production process, reduce losses,
and increase profits.

ETAP Real-Time extends the traditional data acquisition systems to an intelligent and reliable power
management solution for operators, dispatchers, engineers, and decision makers. Its modular
functionality can be tailored to fit the needs of each company, from small to large power systems.
Industrial facilities, transmission, and distribution companies, generation owners, and vertically
integrated utilities can all benefit from the features and functionality of ETAP Real-Time.

Monitoring & Predictive Energy Management Intelligent Load Intelligent


Simulation System Shedding Substation
Advanced Monitoring Automatic Generation Control Load Preservation Substation Automation
• Intelligent graphical user interface • Multi-area control • Steady-state & transient response • Flexible automation
• State estimator & load distributor • Load frequency control • Optimal load preservation • Programmable logic editor
• Process & performance monitoring • MW & MVAR sharing • Fast response time • Online control
• Alarm & notification management • NERC performance standard • Reliable operation
• Minimum load shedding Switching Management
Energy Accounting Economic Dispatch • Proactive contingency analysis • Switching sequence management
• Energy tariff builder • Minimize fuel costs • Safety & security procedures
• Customizable reports • Optimize energy costs Load Restoration • Interlock logic evaluator
• Real-time energy cost tracker • Fast solution • Restart inhibition • Switching plan validation
• Cost & consumption summary • Robust algorithms • Logical load sequencer
• Load restoration priority Load Management
Real-Time Simulation Supervisory Control • Demand-side management
• Simulate circuit breaker operation • System optimization Load Shedding Validation • Time-of-use load shifting
• Identify potential operating problems • Supervisory & advisory • Confirm load shedding actions • Intelligent load management
• Simulate motor starting & load change control system • Simulate ILS recommendations
• Predict operating time of protective • Optimal power flow • Integrated stability knowledge base
devices • Programmable logic editor
• Predict system response based on
operator actions
• Perform “What If” operating scenarios
Interchange Scheduling
• Tariff analyzer
Download a
• Simulate real-time & archived data
• Operator assistance & training
• Rate structure builder
• Transaction scheduling
Free Demo at etap.com
• Transaction contract
Event Playback
• Replay archived historian data Reserve Management
• Investigate cause & effect • Operating reserve analysis
• Explore alternative actions • Reserve capacity monitoring
• Replay “What If” scenarios • Notification of inadequate reserve
• Predict operating reserve
Load Forecasting
• Adaptive bus load forecasting
• Real-time trending
• Load profile library
• Forecasting scenario archiving

Copyright © 2010 Operation Technology, Inc. All rights reserved.