AT AICHE-2004 SEMINAR:
Prepared by
K.M.Babu.
An explosion occurred in a superheated steam line when Saskferco was starting up its
ammonia plant in Saskatchewan, Canada. A steam explosion is a violent vaporization
that can occur when water hits a very hot surface. The volume of expansion of water is
more than 1600 times from Liquid to vapor when water slugs hit a very hot surface. A
steam explosion in U.K. steel works in 1975 caused fatalities. In Saskferco’s case the
explosion’s impact did not injure anyone, but they lost three days production and costs
associated with incidental repairs.
• Overfilling the steam drum and upstream of the Steam Super Heater coil.
• A faulty attemperator valve that led boiler feed water to enter the super heater.
• A faulty check-valve on the steam drum.
The leaking attemperator allowed water to hit hot steel and vaporize explosively. A
slug of water blew back to the super heater, carrying the attemperator nozzle with it.
Steam trapped ahead of the slug, over-pressured an internal super heater component and
damaged it. The incident cost Saskferco about three days of downtime and some minor
repair costs.
It is possible that one can get away with introducing water at a later, hotter stage
of start-up as long as it is carried away by the steam flow. Introducing water during the
initial phase of start up, when there is no steam flow, or when the plant is in a colder
condition, may represent the worst case. Regardless, it is never a good thing to have
water where it does not belong.
This article emphasizes the fact that both beyond High level and beyond low-level
operation of Steam Drum is highly unsafe and can lead to severe damages. Sudden rush
up of water slugs in a small confined or blocked heated space would lead to steam
explosion which eventually might lead to damage of Equipment.
Toyo Engineering and Sumitomo jointly developed a new duplex stainless steel
DP28W™ for mega urea plants and they claim it has an excellent passivating property in
urea carbamate solution.
Duplex SS was used for HP decomposer in 70s, but not used for HP stripper and
carbamate condenser and TEC applied this material in their ACES process.
This paper describes a methodology that was developed in decision making for plant
revamping options. The methodology involves the following steps:
SAFCO used this methodology for two proposals each on ammonia and urea plants.
Based on that, methanator feed pre-heater and urea reactor revamp fell into high category
where as MEA absorber revamp and flare stack for ammonia gas fell into low category,
which could be done in next 2-3 years.
This is primarily an empirical model, modeled with assumed relative criteria numbers for
different situations.
This paper describes the MEGAMMONIA process developed by Lurgi and Ammonia
Casale.
Block flow diagram of Lurgi’s MEGAMMONIA process.
N2
Air ASU
O2
CO Shift Ammonia
CPOx RNWU
Nat Gas (HT Only) Synthesis Liquid NH3
(60 bar) (52 bar)
(55 bar) (200 bar)
Fuel
CO, CH4, Ar
Lurgi has had clients who are leery of the CPOx operating at, 60 bar (870 psig) with
gas feed. Lurgi does have one CPOx with liquid hydrocarbon feed operating at 60
bars. With gas feed they have one operating at 50 bar and several at 40 – 45 bar.
As a variation, Lurgi has offered a CPOx at 40 bars with a compression stage
between the CO shift and RNWU. They claim that it makes little to no difference
on the efficiency.
CO Shift
The CO conversion section consists of a high temperature reactor only. There is no
low temperature reactor as in a conventional ammonia plant. Lurgi has found that
in their process the low temperature reactor cannot be justified. The remaining
unconverted CO is scrubbed in the nitrogen wash unit and used as fuel in the fired
heater.
RNWU – Rectisol, Nitrogen Wash Unit
The gas purification unit consists of a Rectisol unit and a nitrogen wash unit. There
is no methanator as in a conventional ammonia plant. Lurgi removes the catalyst
poisons (CO and CO2) rather than consume H2 converting them to CH4.
Lurgi is the licensor of Rectisol.
The Rectisol unit (a cold methanol absorber) removes the CO2. Lurgi has studied
aMDEA with BASF for such a process and has found that the cutoff for a single
absorber is around 2200 T/d. For 4000 T/d, they calculated three parallel absorbers
were required. The N2 wash unit removes the remaining CO, CH4 and Ar and
returns them to fuel. The plant produces enough CO2 to convert all ammonia to urea
(2.3 MT per year).
Ammonia Synthesis
Despite the large production, the synthesis loop is still conventional employing
magnetite catalyst. The loop is designed by Casale and uses two reactors. The first
reactor has two beds with an internal interchanger. The second reactor has one bed.
There is a waste heat boiler between the two reactors.
Environmental:
There are three key environmental benefits to this process scheme as follows:
1. No LTS means low or no VOC emissions (e.g. methanol).
2. No SMR means low NOx and less noise emissions.
3. Stoichiometric CO2 production means 1⁄3 less emissions to atmosphere provided
there is a sink for the CO2 such as urea.
This paper describes the revamping done at Ultrafertil plant in Brazil that increased
production rates from 520 to 600 tpd. The revamp included following changes to existing
plant.
The above revamp resulted in achieving an average daily production of 614 tpd and
reduced energy consumption by about 10.55%.
Reformer Catalytic Tubes outside wall temperatures reduced from 950. Deg.C to 880.
Deg.C and Synthesis loop pressure reduced by 20 bars. Converter out let Ammonia
Concentration increased from earlier 10% to 14%.
This paper summarized the results of metallurgical examination of HP-Nb & Ti reformer
catalyst tubes after 10 years of use and proved that metallurgical stability of this material
at higher temperature service is better than that of HK-40 and IN519 materials. Creep
rupture strength of HP-Nb & Ti material is higher than that of HK-40 and IN-519
materials, especially, after use at elevated temperature.
The paper highlighted that HP-Nb &Ti had a maximum change of ID less than 1%, which
translates into a remaining life of reformer tubes of about 50,000 hours.
The Author perceives that measuring the inner diameter is a more useful method for
estimating the remaining tube life. If the change is below 1%, the tube is expected to have
more than 50% remaining life.
This paper describes the material and mechanical investigations on different metallic and
non-metallic materials of construction of a M.W. Kellogg design primary reformer outlet
transfer header. The objective of the investigation was to determine in-service
deterioration after 26 years in operation.
1. Deep corrosion pits (60% of wall thickness) in the water jacket, likely to be formed
by oxygen corrosion
2. Fusion line cracking on the steel side of the SA-516-70/Incoly 800H dissimilar metal
welds in transition cone assemblies
3. Extensive sigma formation on metallic liner components
4. No evidence of creep surface carbonization.
5. EDX analysis of weld metals suggests to use the electrodes/filler metals similar to
Inco-weld A and Inconel Filler metal 82 during fabrication.
6. Mechanical properties of refractory much reduced compared to original.
Primary Reformer Transfer header completed 26 years of service and the replacement of
Transfer header was planned as s safe measure, at the same time of furnace re-harp
(Second re-harp) to save time and money.
Mike Just, Steve Pouliot, Chris Grossmann, John A. Nichols and Satish Reddy
Dakota Gasification Company, BASF Corporation
DGC purchased an old CF Braun Ammonia plant (1000 STPD) located at Fort Madison
and shifted total plant to the Beulah site where they are producing synthesis gas using
coal gasification technology. The Fort Madison plant was revamped to 1200 STPD after
shifting to Beulah. Earlier this plant was using catacarb process (Hot potassium
carbonate) for CO2 removal application.
In 1996, when plant was revamped to 1200 STPD capacity CO2 removal section was also
revamped to aMDEA process replacing the earlier Catacarb process (Hot Potassium
Carbonate Process).
The author explains, it is all advantages, and the plant gained in terms of energy saving.
Reduced CO2 slip from absorber and reduced equipment maintenance due to less
corrosion.
The CO2 slip from Absorber reduced to <100 ppm from the earlier CO2 slip value of
1000 to 2000 ppm. LP steam consumption reduced to 9 MT/Hr from the earlier value of
20 MT/Hr.
After considering the increased, pumping power of aMDEA solution, still there is a net
reduction in energy consumption by 30% over the base case in CO2 removal section.
The energy saving is in line with the generally expected savings for an aMDEA revamp
from hot potassium carbonate system.
After merger of M.W.Kellogg and CF.Braun companies this is the first grass roots plant
commissioned combining the technical features of both M.W.Kellogg and CF. Braun
Processes. This plant located in Hainan Province, PR of China was commissioned in
September-2003 and is one of the lowest energy plants.
This plant uses a typical Natural Gas containing 20.7% CO2, 16.8% N2 and 60.7%
Methane and the designer has to make major adjustments in the generally offered process
design to other clients.
This plant was built for CNOOC and has a 1500 tpd of ammonia and 2700 tpd of urea
plant using Stamicarbon technology and Yara urea granulation process.
The Purifier technology enabled CNOOC without any need of CO2 removal at upstream
of primary reformer even though there is a potential increase of severity in reforming
operation. This process allowed methane slip to rise from primary reformer as any
additional methane from it can be removed in cryogenic purifier and it compensates high
severity in reformer operation.
About 28% of N2 is required with the feed to make NH3. With almost 17% N2 in natural
gas, this would normally require significantly lower amount of process air to secondary
reformer, which transfers reforming duty to primary reformer. 17% N2 requires the
primary reformer be operated at higher temperature by about 35 DegC in a conventional
ammonia plant in order to maintain same H/N ratio.
The normal H/N ratio at Purifier inlet is 2.0 and at CNOOC, it is designed for 1.8 to keep
primary reformer exit temperature same as it would have been with H/N ratio of 2.0.
However, CNOOC plant is designed for methane slip of more than 2% from secondary
reformer, higher than normal Purifier process.
The project was kicked off in March 2001 and performance test completed in
March/April 2004. Actual cost of the project was about 89% of the budget cost.
Separate discussions with M/S KBR revealed that CNOOC Plant has been designed for a
cooling water temperature of 32.0 Deg.C.
As part of one of the retrofit projects, a larger size recycle wheel (19”) was installed in
place of an old smaller size recycle wheel in the synthesis gas compressor (103-J) in
anticipation of upgrading the plant capacity to 1800 STPD.
But due to high natural gas prices, the plant has been running at reduced rates for the last
three years making it necessary to throttle the recycle suction motorized valve Sp-70.
This increased the differential pressure (DP) across SP70 and energy usage of 103-J.
Problem noticed: Instrument fittings tapings on the suction and discharge side of the
compressor failed. Total three failures took place.
The original compressor supplier Dresser-Rand was contacted to address the piping
vibrations. Dresser-Rand sent a proposal for trimming the recycle wheel and for
installing a new Duct-Resonator Array in the recycle wheel.
Dress-Rand experience has shown Duct Resonator (D-R) arrays are very effective at
reducing turbo machinery noise at the source.
Finally based on Dress-Rand recommendations recycle wheel was trimmed from 19” to
18.5” size, which would still enable the operation of the plant at 1500 STPD.
A new Duct Resonator array was also designed and installed on the outlet diffuser
wall side of the fan path. The entire mechanical job was done in two weeks time.
The root cause for Synthesis gas compressor high pressure piping vibration was the size
of recycle wheel, which was larger than required. This resulted into pressure pulsations
that transmitted to the Synthesis gas piping.
Trimming the recycle wheel and installation of Duct Resonator array have helped to
reduce the piping vibrations.
Recycle wheel suction valve could be opened fully and compressor energy usage was
reduced due to reduced DP across Sp70 from 100 psig to 10 psig.
The average reduction in noise level achieved is about 10 dB. This average reduction of
10 dB in noise level, due to DR array installation was observed in about 50 other
compressor installations as verified by the Author from the supplier.
Richard D. Roberts
QUEST TruTec LP.
This paper describes remotely operated autonomous inspection tool (Intelligent pig),
Furnace Tube Inspection System (FTIS), that was developed by QUEST Integrated, Inc.
This new technique enables inspection of both convection and radiant section coils in
reformer furnace and it relies on custom designed ultrasonic (UT) technology to acquire
wall thickness, diametrical dimension, and shape information like bulging, swelling, and
ovality, throughout the coils.
The FTIS intelligent pig is transported through the interior of the Serpentine piping coil
via a column of water, which provides propulsion, and coupling for the ultrasonic
transducers. The inspection data is processed and stored on board the FTIS intelligent pig
using high speed digital signal processing.
Features such as internal corrosion, erosion, pitting, bulging, swelling, and deformation
are easily located and quantified. Custom software provides the ability to view the entire
coil in both 2-Dimensioanl and 3-Dimensianl graphics.
The author has presented two case studies of coil inspections using FTIS e.g. crude heater
and vacuum heater and he has mentioned that preliminary results can be available within
minutes after the data are downloaded to make quicker decisions about bringing furnace
on line.
The average overall energy efficiency of ammonia plants has come down to 9.30
Gcal/MT during 2002-03 compared to the value 12.48 Gcal/MT prevailed during 1987-
88. This corresponds to a reduction of 25.5%.
The average energy consumption of 25% most efficient Indian ammonia plants at 8.41
Gcal/MT is lower than 8.49 Gcal/MT for the most efficient 25% ammonia plants in the
world.
The total weighted aver energy consumption of US gas based ammonia plants (42 Nos) is
about 9.94 Gcal./MT where as for Indian ammonia gas based plants (22 Nos.) the value is
9.61 Gcal/MT.
The average energy consumption of (15 Nos.) gas based Indian ammonia plants is lower
at 8.51 Gcal/MT compared to the average energy consumption value of 8.77 Gcal/MT of
Chinese gas based Ammonia plants (8 Nos.)
Jiri Jekerle
ALSTOM Power Energy Recovery GmbH
This paper describes the calculations of the pressure and temperature changes on
the waterside of the waste heat boiler for some transient operating cases. The temperature
changes on the water and gas sides determine the temperature distributions as well as the
time dependent stress distribution in the pressurized parts of the waste heat boiler, which
could affect lifetime of the waste heat boiler.
The study of unsteady operating cases like start up, shutdown or quick trip conditions is
an important engineering step during the planning and design of the ammonia plant
equipment. The knowledge of the transient behavior of the boilers, pressure vessels and
other equipment improve the understanding of possible failures and help to find the root
causes to prevent them and any consequential damages.
The method described in this paper is based on the mass and energy balance and volume
equations for the pressure vessels and equations of specific enthalpy and specific volume
of water and steam.
This method has been previously verified by comparing them with experimental
data obtained from real equipment. The proper use of described simulation method makes
it possible to gain an accurate and pragmatic description of the dynamic behavior of
waste heat boilers.
The boiler feed water pump failure example presented in this paper emphasizes the
necessity to pay detailed attention to the possibility of failures occurring. The results help
to improve the technical and operating reliability and efficiency of whole ammonia plant.
The paper highlighted the need and urgency of reducing the energy consumption of
Ammonia plants as the global natural gas and Hydrocarbon prices are continuously
increasing. Particularly this is applicable to those old vintage Plants which are operating
above the world average benchmark energy value.
Also pointed about various options available to increase the capacity and reduce the
energy consumption.
The Author has presented comparative figures for both pre-reformer and HTER
revamped options of an existing 1500 MTPD ammonia plant to 1650 MTPD Capacity.
When data presented are evaluated the energy number for pre-reformer option has been
found to be on lower side by 0.1 Gcal/MT of Ammonia compared to HTER option.
This particular HTER revamp option will suit those plants where primary reformer is a
bottleneck for increasing capacity, and all other sections of the plant have margins for
envisaged capacity increase. Also this option will suit to a situation where low cost steam
can be imported from a coal-fired boiler available in the complex.
HTER is more like a capacity addition revamp option and will not give any substantial
energy saving.
The IFFCO revamp options, which are under implementation, were also presented with
more detailing on S-50 converters. S-50 converters will be added in series down stream
to the existing converter.
In Kellogg designed IFFCO plants newly added S-50 converter would have a
lower heat exchanger to pre-heat the existing converter outlet gas, which is at a lower
temperature (about 325. Deg.C.).
In Haldor Topsoe designed IFFCO plants the newly added S-50 converter will be without
a lower heat exchanger.
In Kellogg designed IFFCO plants after S-50 converter one new MP steam boiler shall be
introduced and in Topsoe designed IFFCO plants after S-50 converter one HP Steam
boiler shall be introduced.
As per Topsoe the expected energy saving on account of S-50 converter addition alone
shall be between 0.15 Gcal/MT to 0.3 Gcal/MT depending on the plant specifics and
existing loop configurations
This paper describes the successful scale up of Kellogg Reforming Exchanger System
(KRES) from 350 MTPD Ammonia Plant that was first time installed at Kitimat, Canada
in 1994 to a 1000 MTPD Capacity at Liaohe plant in China in 2003. The KRES suited
well for this plant as they were looking at reducing natural gas consumption on site due to
reduced gas supply. Ammonia Plant Process Steam requirement is partly fulfilled by
importing Steam from off-sites Coal fired Boiler.
The Ammonia Plant revamp at Liahoe consisted of replacing the existing Primary
Reformer and Secondary Reformer with a new proprietary KBR designed KRES
system consisting of KRES exchanger, Auto thermal Reformer and Process Heater. Also
O2 enriched Process Air is supplied to the ATR.
KBR has improved its design features of KRES from Kitimat plant to this plant such as:
• Higher operating pressure of KRES from 19 bar to 32 bar
• Reduced tube size of KRES to 1”
• Refractory protected tube sheet design that allows use of SS metallurgy
• Optimised catalyst size & shape
With the KRES, Liaohe plant reduced their natural gas usage from 10.09 to 7.17
Gcal/MT and the net energy consumption of ammonia plant reduced from 10.09 to 9.44
GCal/MT as the required steam is supplied by coal fired offsite boiler at the site.
This paper describes the energy conservation idea by using urea hydrolyser steam as
reformer feed steam in ammonia plant. At Engro, ammonia plant process condensate is
also fed to urea hydrolyser to remove ammonia and methanol from the condensate.
When Engro made first attempt to use hydrolyser steam, they have experienced the
following problems:
• Poisoning of LTS catalyst from chlorides, which got into process condensate from a
leaking CW exchanger in CO2 removal section.
• Deactivation of pre-reformer catalyst due to the presence of sulphates in hydrolyser
vent stream which otherwise being vented before this change.
• High ammonia content in CO2 product from ammonia plant resulted in carbamate
formation and corroded Cu-Ni exchangers in urea plant.
Later on, Engro procured an on-line Ion Chromatograph to measure chlorides and
sulfates to ppb levels and Cu-Ni exchangers in urea plant were replaced with SS. The
urea hydrolyser vent steam was again lined up to ammonia plant reformer and found no
problems as Engro was closely monitoring the chloride and sulphate levels. They have
also developed new operating procedures to divert urea hydrolyser steam to vent in case
of any abnormalities in its quality that is analysed with Ion Chromatograph.
As a result, Engro successfully saved energy and improved site environmental standards
by reducing ammonia, and methanol emissions into atmosphere.
The essence of the whole project lies in improved monitoring techniques and stringent
monitoring standards without which it can cause damage to the process far exceeding its
benefits.
David Craig
Agrium
Summary:
• Reverse rotation of pumps, especially due to a high-pressure gas or vapor, can result
in a catastrophic failure of pump and driver.
• Using manual block valves for emergency isolation is not an option if the manual
block valves are too large.
• The use of sealant compounds should only be viewed as a temporary fix.
• Management of change (or modification assessment) is required to control and review
potential issues when using leak sealant compounds.
• Standardized operating procedures during normal change over, start up & shut down
of pumps have to be religiously followed and communicated to all the concerned.
Consider check valves as protection against reverse flow on a pump trip but not as
part of the normal operating system for starting and stopping pumps.
This paper describes Stamicarbon’s new fluid bed urea granulation process that was
installed in Agrium’s Fort Saskatchewan plant. Agrium granulation plant has two lines
of 625-mtpd capacity each, commissioned in the year 2003. This new process consumes
about half of the normal usage of urea formaldehyde and has less dust formation and
Stamicarbon claims it’s because of low-pressure film sprayer process with no atomizing
air. This new granulation process was first applied at Grodno’s plant in Belarus.
The reduced formaldehyde consumption would offer attractive savings to urea producers
and the granulation plant ran for more than three months without granulator washing at
Agrium plant.
This paper discusses the application of risk assessment technology in general, and more
specifically Risk Based Inspection (RBI). Studies of RBI as applied to ammonia storage
and handling have been performed to analyze the hazards presented by corrosion or other
ongoing degradation of equipment.
The primary elements of RBI are consequence and frequency and secondary elements are
inspection effectiveness and its impact on damage likelihood.
The RBI results are carefully calibrated to match other risk assessment efforts focusing
on other hazards. By presenting the results of all risk assessments using similar metrics,
management is provided with a powerful tool to make decisions regarding application of
resources to control threats to Safety, Health & Environment.
Stanley Reid
PCS Nitrogen, Trinidad
This plant has noticed seventy-six cracks on the dome of the tank at insulation clips and
at long seams. A metallurgical review of the cracks identified the cause of cracking to be
stress corrosion cracking by ammonium nitrate. This type of cracking is found under
poorly sealed insulation when high stresses, usually caused by welds that were not stress
relieved and accentuated by relatively warm temperatures. The presence of ammonium
nitrate from atmosphere and its exposure to air contributed to SCC.
The cracking resulted when the ammonium nitrate was dissolved in rainwater and washed
through crevices in the insulation on to the metal surfaces.
The engineering assessment, the AE test and the NDE performed, all showed the tank's
shell and floor were in sound condition. AE test was not done on the Dome and no results
were available for comparison with conventional NDE test results.
This paper describes a rigorous assessment procedure used to develop inspection plans
for ammonia storage tanks, bullets and Horton spheres. The procedure includes a
qualitative review of data, a risk based inspection (RBI), assessment of storage vessel and
its associated piping and related pressure equipment, a fitness for service (FFS)
evaluation of the storage vessel, an analysis of associated piping, and assessment of
pressure relief capacities.
This company assessed a half a dozen ammonia storage units and developed plans that
emphasize non-intrusive technology to avoid SCC damage associated with warming and
opening of storage vessels for inspection. They claim that risk of SCC and other safety
concerns inherent with decommissioning may be far greater than risk of continued
service with less frequent internal inspection while providing more in-service inspection
and monitoring.
Author also expressed the views that Inspecting for SCC could be a difficult task.
Ammonia cracks are generally shallow with a high length to depth ratio. Every inspection
technique has a threshold for detectable crack size and small cracks may not be detected
by any inspection technique. However based on the advancements made in the sensitivity
of inspection methods, intrusive methods involving surface inspection, and a non-
intrusive technology, acoustic emission (AE) testing, can be used to inspect for crack like
flaws.
However, along with complexities related to the finding and sizing SCC surface
flaws, intrusive inspection introduces the additional complication of oxygen
contamination.
This paper details how to improve the performance of primary reformer by the correct
catalyst selection and application of good design techniques when considering primary
reformer re-tubes. Common modes of reformer tube failures are generalized and localized
overheating. Reformer tubes can be inspected using destructive testing, visual inspection,
acoustic emission, eddy current, radiography and laser profilometry (LOTIS). As per the
Author Laser Profilometry is the most accurate method available for Reformer tube
inside diameter measurement and therefore the amount of creep strain the tube has
suffered.
Catalyst type & size, promoters used in catalyst and catalyst loading method would have
significant impact on reformer tube stresses. The catalyst size & shape should be
optimized such that it gives good turbulence of process gas for better heat flux
distribution and to keep metal skin temperature of tubes at the lowest possible level.
Modern catalyst loading method such as UNIDENSE achieves less pressure drop
variation and hence reduced tube wall temperature (TWT) variation.
Two case studies of reformer re-tube projects were presented where significant
improvements noticed with thin wall tubes and low DP catalyst loading technique and
this has helped to reduce TWTs.
The relative strength of HP micro Alloy tubes is 2.2 times higher than that of HK-
40 tubes. This strength improvement is due to the increased amount of Secondary
carbides, which are finely distributed throughout the parent material. They prevent the
movement of dislocations through the material and hence resist the movement reducing
the extent of creep damage.
In HK-40 only the chromium forms the Carbides whilst for the later alloys, Niobium
forms secondary carbides. Titanium, zirconium, Tungsten, and cesium are all strong
carbide formers and form finer carbides that last longer, providing higher strengths that
are retained for longer. These higher strengths allow for a reduction in tube wall
thickness when utilizing modern Alloys.
This paper shares the experience of upgrading an old and obsolete pneumatic emergency
shutdown system with a Triple Modular Redundant (TMR) electronic system. Addition to
the already existing trips, new trips such as S/G ratio, furnace low draft, WHB steam
drum low level, Furnace coils protection w. r. t BFW circulation and some CO2 removal
system protections were added to the new ABB system while switching over from
Pneumatic to Electronic system.
Engro used the following strategy in developing a new emergency shutdown system:
Additions and deletion of trips based on their own experience and industrial networking
has been implemented.
In 1995 Engro Chemicals had a bitter experience of dry out operation of Secondary
Reformer effluent waste heat Boiler that resulted in substantial damage. This incident
forced the plant management to think about more safe and advanced instrumentation so
that efficient control systems could be configured for Safe handling of the Plant. Other
human aspects like dependency on certain skilled personnel, response time & efficiency,
judgment of individuals were also deliberated before change over to electronic control
system. .
George S. Price
Plant Safety Analysts Inc.
Paper was not presented during the Seminar but the Summary of the text of the
Paper is as under:
Many parallel sub-processes do take place within the systems during the course of
operation of a large scale Process Plant. These sub-processes many times remain
unnoticed, as they happen to be on a very smaller scale and without interrupting the Plant
Operation. But these sub-processes may lead to major incidents and can cause loss of
property and injury to the operating personnel.
1.0 Spillage of Oil drops from Bearing End covers, Valves Glands & Bonnets.
(If continued/ or remained unnoticed may lead to fire incidents and disrupt plant
operation. Also may cause fall of people due to slippery ground/floor situations
caused by Oil leaks.)
2.0 Waste cotton/ Scaffolding Material used for Cleaning & Repair of Equipment.
(If not disposed/removed properly & timely may lead to a fire situation. Waste cotton
fallen accidentally in Process equipment may block the flow passage in Pipes or
Equipment.)
This paper describes recent experience with carbon, 1/2 moly steels. High temperature
hydrogen attack (HTHA) has caused significant damage to piping and pressure vessels.
Non-destructive testing (primarily ultrasonic) detected the damage. Macro cracks in heat-
affected zones are one form of HTHA damage that seems to occur particularly in newer,
alloy-steel vessels. Pressure equipment should be rejected in accordance with API 579.
As per the 5th edition of API941 “ Steels for Hydrogen Service at Elevated
Temperatures and Pressures in Petroleum Refineries and Petrochemical Plants”, The C-
0.5 Mo Safe working line has been removed from the Nelson Curves within this code.
This now means that C-0.5 Mo material usage for H2 Service at elevated temperatures
and pressures is not recommended and is treated at par with normal Carbon Steel
material.
The Author opined that Fitness for Service of a Vessel is decided by assessing not
only the primary applied stresses such as hoop stress (Generated by internal pressure) but
also require a knowledge of secondary stresses such as thermal and residual stresses.
Further when HTHA has been detected and the detected level of damage restricts
detection of macro cracks, then that material/Equipment would not be fit for service.
Vasilis M. Fthenakis
Brookhaven National Laboratory, Upton, NY
Using LPOOL evaporation model, the author calculated that about 1% of the rainout
ammonia evaporated during the first few minutes. Using ALOHA
/DEGADIS and SLAB, the author determined that concentrations of ammonia in excess
of the ERPG-3 level of 750 ppm extended to 4.3 to 5.8 miles.
Jorge A. Camps
Jacobs Consultancy Inc.
All these projects were not typical repeat exercises and each one involved one or more
elements of innovation or technical project risk. Some lessons learned were:
a) None of the projects failed, but each had a different measure of success. Some of
these new projects had lower than expected initial production rates for variety of
reasons.
If there are multiple “firsts” or trend-setting aspects, consider whether these may
feed on each other or create potential “frightening combinations”. If so, mitigate the risk
or avoid them altogether. As a rule of thumb, two or more significant “firsts” may
constitute a frightening combination for a major industrial project.
This paper provides a broader overview of key modeling techniques showing how each
can be applied to provide valuable insight into particular aspects of reformer design and
operation.
The modelling of individual parts of the reformer such as inlet header systems, burners,
radiant box, tubes, outlet header, tunnels, convection section, coils and catalyst size &
shape are discussed in detail.
This paper reviews the recent developments in urea technology and they include:
a) Urea synthesis technology for large-scale single unit grass root plants up to 4,500 mt
using equipment such as pool condenser, and pool reactor, of Stamicarbon, Toyo’s
Vertical Submerged Condenser and Casale’s Full Condenser.
b) Use of new materials such as Duplex steels (27-28% Cr min) and Safurex v/s 25/22/2
L austenitic steels for improved corrosion resistance and mechanical strength.
c) Urea granulation using new Stamicarbon FBG Process.
d) Advanced feature for urea cooling with Fluidised Bed Cooler as bulk flow cooler has
relatively restricted application.
For a typical 2000 MTPD Urea plant the power consumption for a Fluidized Bed Cooler
is about 1.8 MW compared to the 200 KW needed by the Bulk flow cooler facility.
This paper describes the acoustical emission inspections conducted on five pressure
swing adsorption (PSA) vessels and six molecular sieve dryers at two Agrium facilities.
The acoustical emission testing was followed up with an internal inspection of two PSA
vessels and three molecular sieve dryers.
1. The AE did not pick up any small defects on one of the vessels those were found
upon internal inspection.
2. The AE did show some cracks on another vessel, but no cracks found upon internal
inspection.
3. Internal inspection of molecular sieve dryers did not indicate any evidence of
deterioration to their mechanical integrity.
Though the partial pressure of H2 in the Process gas handled by PGR Dryers is
less than the partial pressure of H2 in the make up Synthesis gas Dryers of Ammonia
Plant (Where ever they are used), it would be prudent to check PGR plant Dryers without
remaining complacent.
• Catalysts: poisons, carbon formation and hot tubes, catalyst breakage, the effect of
water, and catalyst loading
• Reformer tubes: hot tubes, tube failure, generalized & localized overheating, stress
corrosion cracking of tube tops and bottoms, bowed tubes, pigtails, and risers
• Radiant boxes: flue gas mal-distribution.
(Mal-distribution could be due to improper adjustment of Air dampers for individual
row of Burners which might result in post burning scenario in some of the rows,)
• Burners: after-burning, excessive air, fan issues
• Header designs: fuel and fuel header designs including symmetry problems
• Refractory: general damage, damage to anchors and tracking behind refractory.
(Refractory anchors MOC selection should be done carefully keeping in view the
most severe conditions.)
• Coffins (Also known as Tunnels): Damage to the coffins would lead in mal-
distribution of flue gases resulting in higher bottom skin temperature of tubes in some
banks.
• Risers Protection: On one Kellogg Reformer, the Risers suffered from significant
cracking around 30% of the way down the riser caused by flame impingement due to
flame deviation from the vertical. As a short term fix the upper part of the Riser was
insulated. This would cause a marginal reduction in radiant box efficiency.
The Author also presented some of the advantages of UNIDENSE CATALYST LOADING,
which will address some of the problems associated with Primary Reformer Operation.
KRIBHCO’S Perspective: UNIDENSE loading may give some qualitative benefits. But
calculating the cost advantage over conventional loading is not a simple straightforward
method. Majority of the problems explained by the Author would creep in during the
course of Plant Operation and cannot be attributed directly to Catalyst Loading.
This paper suggests using methanol, as feedstock to make ammonia in place of natural
gas and it might be an attractive option for ammonia producers in USA and India who are
planning to invest on offshore plants.
The author presented the following strategies for the survival of the US nitrogen industry:
1. Do nothing and maintain status quo. That means operate plants at lower natural gas
prices and shutdown plants at higher prices.
2. Change feedstock to LNG. Most of the time, importing LNG is not cheaper than it
can be purchased from US gas grid.
3. Change to coal or petroleum coke as feedstock. Although, this route may ensure
business survival in the longer term, the capital penalty is severe, and the economic
viability is doubtful.
4. Relocate ammonia production capacity to low gas cost country and ship liquid
ammonia back to US. The market for direct injection of ammonia as fertiliser is
falling. CO2, which is essential for the production of urea and UAN solutions, does
not accompany the liquid ammonia.
5. Relocate entire fertiliser production capacity to a low gas cost country and ship
urea/UAN direct to US customers. There could be an objection of US agriculture
lobby to the exposure of imported fertilisers and security concerns with the import of
nitrate solutions.
6. Locate low cost methanol from a low gas cost country, ship it to USA and convert it
into ammonia.
A new methanol reformer can be added to existing plant and the entire hot front end of
ammonia plant can be taken out of service (including shift converters). The methanol-
reformed gas can be directly fed to CO2 removal unit and one can still use the existing
backend of ammonia plant.
The current cash cost of producing UAN from natural gas on the US Gulf Coast is
$88.30. The cash cost of making one ton of UAN based on imported methanol feedstock
would be $43.78 and hence, the author feels that making ammonia from methanol could
be an attractive option for US fertilizer producers.
*****