Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 10-8-10 JN - BB
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
4052005 Circular VCP 18
Site ID: Address: Site Quality: Basin:
59 7030 S. 110th St. Good

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? No Manhole Depth (ft): 19.73 Surcharge Evidence? No
Needed Traffic Attendants: Manhole Dia. (in): 54 Depth of Surcharge (ft): 0
H2S: 0 O2: 20.8 MH Cover Size (in): 24 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: Pick Usable MH Steps? Yes
Describe potential hazards: Measured Flow Depth (in): 3 Meter: 2150
Velocity (fps): 3.5 Cellular Signal Strength: Good
Down steep hill
Mounting Band Description: Antennae Install Considerations:

Scissor jack, spring band, partial Locking, above ground box


band

Other Comments: Permanent Power Available?


Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)

SURFACE DOWN

INFLOW OUTFLOW