Professional Documents
Culture Documents
Modal Pushover Analysis of SAC Buildings
Modal Pushover Analysis of SAC Buildings
Modal Pushover Analysis of SAC Buildings
curve (Fig. 3a). The gravity loads were not included 2.04 −1.13 −2.93
in the higher mode pushover curves, which generally 1.75 −1.8 −1.38
do not exhibit negative post-yielding stiffness (Fig. 1.44 −2.1 0.728
3b). 1.12 −2.03 2.37
3. Idealize the pushover curve as a bilinear curve (Fig. 0.796 −1.67 2.94
4). If the pushover curve exhibits negative post- 0.487 −1.1 2.31
9
H Fsny JK
8 T = 0.49 sec
3
For an SDF system with known Tn and z n , Dn can
7 T = 0.85 sec
2
be computed by nonlinear response history analysis
6 (RHA) or from the inelastic design spectrum
5 T = 2.27 sec
1 (Chopra, 2001, Section 7.11).
Floor
4
3
6. Calculate peak roof displacement urn associated
2
with the nth-“mode” inelastic SDF system from
1
urn = Gnf rn Dn
Ground
−1.5 −1 −0.5 0 0.5 1 1.5
Mode Shape Component 7. From the pushover database (Step 2), extract values
of desired responses rn : floor displacements, story
Fig. 1: First three natural-vibration drifts, plastic hinge rotations, etc.
periods and modes of the 9-story
8. Repeat Steps 3-7 for as many modes as required for
SAC-Los Angeles Building
sufficient accuracy. Typically, the first two or three
“modes” will suffice.
9. Determine the total response (demand) by
V
combining the peak “modal” responses using the bn (a) Idealized Pushover Curve
SRSS rule:
F I
Idealized
1/ 2 V αnkn
r ª G Â rn J
2 bny
1
Hn K Actual
kn
1
6000
Base Shear (kN)
F /L (b) F / L − D Relationship
sn n sn n n
4000
Vbny / Mn
*
α ω2
n n
1
2000
0 2
0 50 100 150 200 ωn
Roof Displacement (cm) 1
6000
Base Shear (kN)
2000
SAC Buildings and Ground Motions
Floor
4
The dynamic performance characteristics of SAC
3
buildings were evaluated in a comprehensive study of
2
story drift demand predictions through nonlinear RHA
(Gupta and Krawinkler, 1999). Studied were the 1
distribution of story drift demands over the height of the Ground
structures, the relation between story drift and roof drift, 0 1 2 3 4 5
Story Drift (%)
and the effect of modeling accuracy. Shown in Fig. 5 are
the median values of story drift demands over the height (b) 20−Story Buildings
of the buildings for Pre-Northridge M1 models of the 20
structures. “Median” refers to the exponent of the mean
of the natural log of the demand values due to 20 ground 16
motions. LA
12 SE
The distribution of story drift demands over the height of BO
Floor
The story drifts presented cover a wide range of response The MPA procedure was implemented for each of the
from slightly beyond yielding—in the case of Boston six buildings and for each of the 20 ground motions.
structures—to very large demands—in the case of Los Contributions of the first three “modes” or the first five
Angeles buildings—that represent response far into the “modes” were considered for the 9-story buildings and
inelastic range. 20-story buildings, respectively. The combined values of
story drifts were computed for the 9-story building
including one, two, or three “modes” and for the 20-
story building including one, three, or five “modes.”
Figure 6 shows these median values of story drift
demands together with the results of nonlinear RHA
obtained from Fig. 5.
Figure 6 shows that the first “mode” alone is inadequate next the errors in the MPA procedure with those in the
in estimating story drifts. However, by including the RSA procedure.
response contributions due to the second “mode” for the
9-story buildings and second and third “modes” for 20- For this purpose, elastic analysis of each building was
story buildings the numbers are more accurate. With implemented by RSA and RHA methods. The relative
sufficient number of “modes” included, the height-wise errors in story drift demands determined by the RSA
distribution of story drifts estimated by MPA is procedure, also shown in Fig. 7, lead to the following
generally similar to the trends noted from nonlinear observations.
RHA observed in the preceding section.
• Depending on the structure and its location, RSA
Accuracy of MPA Procedure (with three modes for the 9-story buildings and five
modes for 20-story buildings) underestimates the elastic
Figure 7 shows the errors in the story drift demands response by 15% to 30%. The RSA errors are essentially
estimated by the MPA procedure, including uniform over the height of the structures;
contributions of sufficient number of modes: three
modes for 9-story buildings and five modes for 20-story • The errors in MPA are essentially the same as in
buildings. These results permit the following RSA for the 9-story Boston structure because it remains
observations: essentially within the elastic range;
• The MPA procedure underestimates seismic • The MPA errors are larger than RSA in the case of
demands in most stories of the Boston structures by the 20-story Boston building because modest yielding
about 20%; in few upper stories, the error may approach occurs in upper stories;
30%.
• The MPA errors are larger than RSA in upper stories
• The MPA procedure estimates to acceptable but smaller in lower stories in the case of Seattle
accuracy seismic demands in the lower stories of the 9- buildings that undergo significant yielding; and
story and 20 Seattle buildings, but underestimates
demand near the top of the building by up to 30%. • The MPA errors vary irregularly over height and are
much larger than RSA errors for the Los Angeles
• The MPA procedure is least accurate in estimating buildings because near-fault ground motions drive their
seismic demands for the LA buildings. response far into the inelastic range.
Errors in the MPA procedure for inelastic systems arise Comparison of Modal and FEMA Pushover
from several assumptions and approximations, but Analyses
principally from: (1) neglecting coupling among modal
coordinates associated with the modes of the FEMA-273 Force Distributions
corresponding linear system arising from yielding of the
system; and (2) estimating the total response by We consider only one step in the nonlinear static
combining the peak “modal” responses using the SRSS procedure in the FEMA-273 document (FEMA, 1997).
rule. The modal coordinates are indeed uncoupled for The pushover curve, a plot of base shear versus roof
elastic buildings, and the MPA procedure is equivalent displacement, is determined by nonlinear static analysis
to standard response spectrum analysis (RSA). The RSA of the structure subjected to lateral forces with invariant
procedure, implemented in most commercial software, distribution over height but gradually increasing values
has become a standard analytical tool for the structural until a target value of roof displacement is reached. The
engineering profession. The principal source of gravity load is applied prior to the pushover analysis.
approximation in this procedure is in using modal The floor displacements, story drifts, joint rotations,
combination rules to combine the peak modal responses plastic hinge rotations, etc., computed at the target
to estimate the total response. As these errors are displacement represent the seismic demands on the
considered acceptable by the profession, we compare structure.
FEMA-273 specifies three distributions for lateral Obviously, the MPA procedure performs much better
forces: than FEMA force distributions in estimating story drift
demands.
1. “Uniform” distribution: s*j = m j , the mass at the jth
Acknowledgments
floor level (where the floor number j = 1, 2… N );
This research investigation is funded by the National
2. Equivalent lateral force (ELF) distribution: Science Foundation under Grant CMS-9812531, a part
s*j = m j h kj where h j is the height of the jth floor of the U.S. Japan Cooperative Research in Urban
above the base, and the exponent k = 1 for Earthquake Disaster Mitigation. This financial support is
fundamental period T1 £ 0.5 sec , k = 2 for gratefully acknowledged. Our research has benefited
from discussions with Helmut Krawinkler of Stanford
T1 ≥ 2.5 sec ; and varies linearly in between; and
University, and Chris Poland, Jon Heintz, and Kent Yu
of Degenkolb Engineers, Inc.
3. SRSS distribution: s* is defined by the lateral forces
back-calculated from the story shears determined by References
response spectrum analysis of the structure, assumed
to be linearly elastic. BOCA, 1993, National Building Code, 12th Edition,
Building Officials and Code Administration
Comparative Evaluation International Inc., Country Club Hills, Illinois.
Compared next are the story drift demands for each Bracci, J.M., Kunnath, S.K. and Reinhorn, A.M., 1997,
building determined by five analyses: pushover analysis “Seismic Performance and Retrofit Evaluation for
using the three force distributions in FEMA-273, MPA Reinforced Concrete Structures,” American Society of
considering three or five “modes,” and nonlinear RHA. Civil Engineers, Journal Structural Engineering, Vol.
The target roof displacement in the analyses using 123. No. 1, pp. 3-10.
FEMA force distributions was taken as equal to its value
determined by the MPA procedure to achieve a Chopra, A.K., 2001, Dynamics of Structures: Theory
meaningful comparison of the two methods, as shown in and Applications to Earthquake Engineering, 2nd
Fig. 8. Edition, Prentice Hall: New Jersey.
As clearly demonstrated in the figure, the height-wise Chopra, A.K. and Goel, R.K., 2001, “A Modal Pushover
variation of story drifts determined from the FEMA Analysis Procedure to Estimate Seismic Demands for
force distributions differs considerably from nonlinear Buildings: Theory and Preliminary Evaluation,” Report
RHA. Clearly, the FEMA force distribution procedure is No. PEER 2001/03, Pacific Earthquake Engineering
inadequate; it does not predict: Research Center, University of California, Berkeley,
California.
• the increasing drifts in the upper stories of Boston
structures; Fajfar, P. and Fischinger, M., 1988, “N2—A Method for
Nonlinear Seismic Analysis of Regular Structures,”
• the concentration of large story drifts in the upper Proceedings, Ninth World Conference on Earthquake
stories of Seattle structures (especially in the 20-story Engineering, Vol. 5, pp. 111-116, Tokyo-Kyoto, Japan.
building); and
FEMA, 1997, NEHRP Guidelines for the Seismic
• the complex variation of story drifts over the height Rehabilitation of Buildings, FEMA-273, Building
of the 20-story Los Angeles building. Seismic Safety Council, Federal Emergency
Management Agency, Washington, D.C.
Gupta, A. and Krawinkler, H., 1999, “Seismic Demands
for Performance Evaluation of Steel Moment Resisting
Frame Structures (SAC Task 5.4.3), Report No. 132,
John A. Blume Earthquake Engineering Center, Stanford
University, Stanford, California.
6
NL−RHA 12 NL−RHA
5
Floor
Floor
MPA MPA
4
1 "Mode" 8 1 "Mode"
3 2 "Modes" 3 "Modes"
2 3 "Modes" 5 "Modes"
4
1
Ground Ground
0 0.5 1 1.5 2 0 0.5 1 1.5 2
Story Drift (%) Story Drifts (%)
(c) Seattle 9−Story Building (d) Seattle 20−Story Building
9 20
8
7 16
6
12 NL−RHA
5
Floor
Floor
MPA
4
NL−RHA 8 1 "Mode"
3 3 "Modes"
MPA 5 "Modes"
2
1 "Mode" 4
1 2 "Modes"
3 "Modes"
Ground Ground
0 1 2 3 4 5 0 1 2 3 4 5
Story Drift (%) Story Drifts (%)
(e) Los Angeles 9−Story Building (f) Los Angeles 20−Story Building
9 20
8
7 16 NL−RHA
6 MPA
12 1 "Mode"
5 3 "Modes"
Floor
Floor
NL−RHA 5 "Modes"
4
MPA 8
3
1 "Mode"
2 2 "Modes"
4
1 3 "Modes"
Ground Ground
0 1 2 3 4 5 0 1 2 3 4 5
Story Drift (%) Story Drifts (%)
Floor
4
8
3
2
4
1
Ground Ground
0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2
Ratio of MPA or RSA to RHA Ratio of MPA or RSA to RHA
−100 −75 −50 −25 0 25 50 75 100 −100 −75 −50 −25 0 25 50 75 100
Error (%) Error (%)
(c) Seattle 9−Story Building (d) Seattle 20−Story Building
9 20
8
7 LE−RSA 16 LE−RSA
6 MPA 3 "Modes" MPA 5 "Modes"
5 12
Floor
Floor
4
8
3
2
4
1
Ground Ground
0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2
Ratio of MPA or RSA to RHA Ratio of MPA or RSA to RHA
−100 −75 −50 −25 0 25 50 75 100 −100 −75 −50 −25 0 25 50 75 100
Error (%) Error (%)
(e) Los Angeles 9−Story Building (f) Los Angeles 20−Story Building
9 20
8
7 LE−RSA 16
6 MPA 3 "Modes"
5 12 LE−RSA
Floor
Floor
4 MPA 5 "Modes"
8
3
2
4
1
Ground Ground
0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2
Ratio of MPA or RSA to RHA Ratio of MPA or RSA to RHA
−100 −75 −50 −25 0 25 50 75 100 −100 −75 −50 −25 0 25 50 75 100
Error (%) Error (%)
Fig. 7: Errors in the median story drift demands estimated by (1) MPA procedure
for inelastic systems, and (2) RSA procedure for elastic systems
(a) Boston 9−Story Building (b) Boston 20−Story Building
9 20
8
7 16
6 NL−RHA NL−RHA
MPA, 3 "Modes" 12 MPA, 5 "Modes"
5
Floor
Floor
FEMA FEMA
4
Uniform 8 Uniform
3 ELF ELF
2 SRSS SRSS
4
1
Ground Ground
0 0.5 1 1.5 2 0 0.5 1 1.5 2
Story Drift (%) Story Drift (%)
6 NL−RHA NL−RHA
MPA, 3 "Modes" 12 MPA, 5 "Modes"
5
Floor
Floor
FEMA FEMA
4
Uniform 8 Uniform
3 ELF ELF
2 SRSS SRSS
4
1
Ground Ground
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Story Drift (%) Story Drift (%)
(e) Los Angeles 9−Story Building (f) Los Angeles 20−Story Building
9 20
8 NL−RHA NL−RHA
7 MPA, 3 "Modes" 16 MPA, 5 "Modes"
6 FEMA FEMA
Uniform 12 Uniform
5 ELF ELF
Floor
Floor
4 SRSS SRSS
8
3
2
4
1
Ground Ground
0 2 4 6 8 0 2 4 6 8
Story Drift (%) Story Drift (%)