How To Update FA100 Program
How To Update FA100 Program
Updating program
5.1 General
The FA-100 uses five CPUs which run with an individual program.
Table 5.1.1 Program
When the program number differs from one in the above list, update the program again
with the correct selection of the Loader File.
JP6
JP7
5-2
5.1 General
[MEMORY TEST]
ROM RAM
MAIN : OK OK
SUB : OK OK
H8S1 : OK OK
H8S2 : OK OK
H8S3 : OK OK
[ERROR]
BACKUP ERROR !
ESC :[ENT]
5-3
5.2 Program files
5-4
5.3 MAIN CPU
5-5
5.3 MAIN CPU
Port setting
Loader File selection
Status window
Start button
6. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”.
8. After hearing a beep, click [Start] in UPW window during the presence of the
FURUNO logo on the FA-100 screen. The updating starts automatically.
FURUNO logo
plotter display
Press [Start] during
this period.
5-6
5.3 MAIN CPU
9. The messages appear in the ”Status” window on the PC. The display of the
FA-100 changed to plotter display.
12. Press [MENU][7] and [1] to confirm the program number and version,
245-0001-00x. Press [CLR], shows the program version in detail; 245-0001-00x0x.
5-7
5.4 SUB CPU
5-8
5.4 SUB CPU
SH3 SUB
Status window
Start button
6. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”.
8. After hearing a beep, click [Start] in UPW window during the presence of the
FURUNO logo on the FA-100 screen. The updating starts automatically.
FURUNO logo
5-9
5.4 SUB CPU
9. The messages appear in the ”Status” window on the PC. The display of the FA-100
remains unchanged (FURUNO logo).
12. Press [MENU][7] and [1] to confirm the program number and version,
245-0002-00x. Press [CLR], shows the program version in detail; 245-0002-00x0x.
5-10
5.5 H8S1/2/3
5.5 H8S1/2/3
5.5.1 Connection for updating H8S1/2/3
The PC is connected to LOG CONTACT(AUX-1) port (J5) as shown in Fig. 5.5.1.
The interconnection cable is arranged locally. Make shorts between #4 and #6, and
between #7 and #8 on the COM port of the PC.
Setup to PC
1. Insert the H8S program disk into the PC.
2. Download all files in the disk to your desktop. The files are;
- ComHost.exe, Loader.bin: used to download the program
- H8S1.bin: H8S1 program
- H8S2.bin: H8S3 program
- H8S3.bin: H8S3 program
5-11
5.5 H8S1/2/3
Status window
Start button
5. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”.
Setup to FA-100
6. Press [MENU][7] and [7]. The display asks the password to access to the
“SERVICE” menu.
[ENTER PASSWORD]
PASSWORD:
7. Type password (xxxxxx) followed by [ENT], and the service menu appears.
[FOR SERVICE]
1 TX/RX TEST
2 SIO TEST
3 ALARM HISTORY
4 SET CH&PWR
5 H8S RESET
5-12
5.5 H8S1/2/3
8. Press [5] to select ”H8S RESET”. “H8S LOADER RESET menu” is displayed.
H8S1 RESET
H8S2 RESET
H8S3 RESET
9. Select the loader to be reset by using [!] or ["] key and press [ENT].
The menu changes to ”H8S RESET”.
[H8S RESET]
H8S x PROGRAM Note: To close this window, turn off the PC.
LOADING……
Start
10. Click [Start] in the BOOT LOADER window. The new program is installed on
to the FA-100 automatically. The messages appear in “Status” window. The
FURUNO logo on the FA-100 is remains unchanged.
5-13
5.5 H8S1/2/3
5-14