Wall type series On/Off - MVE

- preliminary technical data sheet -

MITSUI CODE MVE9HL4 MVE12HL4 MVE18HL4 MVE24HL4

Frig / h 2320 2780 4160 5290


Cooling W 2696 3234 4840 6157
BTU/h 9200 11000 16500 21000
Capacity rated
kCal / h 2470 3020 4530 6040
Heating W 2871 3513 5271 7030
BTU/h 9800 12000 18000 24000
Humidity extraction rate L/h 0,8 1,0 2,0 3,0
Working temperature range °C -7 ≤T≤+43 -7≤T≤+43 -7≤T≤+43 -7≤T≤+43
Cooling W 795 995 1498 1869
Power input rated
Heating W 780 929 1373 1936
EER 3,39 3,25 3,23 3,29
Energy efficency class A A A A
Annual energy consumption kWh 411 502 730 950
COP 3,68 3,78 3,84 3,63
Heating performance class A A A A
V - Hz 230 - 50 230 - 50 230 - 50 230 - 50
Power supply
Phases 1+N 1+N 1+N 1+N
Cooling W 1000 1450 1980 2600
Max power input
Heating W 1120 1400 1980 2700
Cooling A 3,60 4,51 6,78 8,46
Current input rated
Heating A 3,53 4,21 6,22 8,77
Starting current A 21 24 32 40
Indoor dB(A) 30/33/35 31/34/36 37/41/45/49 38/41/44/47
Sound Pressure Level
Outdoor dB(A) 50 52 55 ≤56
I.U. air capacity (max speed) m3/h 400 550 850 850
width mm 730 790 940 940
Indoor units dimensions height mm 255 265 298 298
depth mm 174 177 200 200
width mm 785 798 848 913
Outdoor units dimensions height mm 540 540 540 680
depth mm 320 320 320 378
Indoor kg 8 9 13 13
Weight
Outdoor kg 31 35 40 46
Type R410A R410A R410A R410A
Refrigerant
Charge kg 0,76 0,82 1,10 1,45
Suction in 3/8 1/2 1/2 1/2
Pipe diameter
Delivery in 1/4 1/4 1/4 1/4
Max refrigerating pipe length m 20 20 20 20
Max stand. charge pipe length m 4 4 5 4
Supplementary charge pipe g/m 30 30 30 50
Maximum difference in level m 10 10 10 10
Compressor Type Rotary Rotary Rotary Rotary
Loading capacity 20'/40'/40'HC 108/228/263 108/233/257 88/183/217 66/138/156

NOTE: The above data have to be considered just as preliminary data, they are subject to change without notice