The 30 A box is used to measure currents between 1 A and 30 A using a Hall sensor element. It connects to CASSY modules via 4 mm safety sockets and can measure both DC and AC currents. When connected, the 30 A box is automatically recognized and measurement quantities and ranges are set using CASSY Lab software.
The 30 A box is used to measure currents between 1 A and 30 A using a Hall sensor element. It connects to CASSY modules via 4 mm safety sockets and can measure both DC and AC currents. When connected, the 30 A box is automatically recognized and measurement quantities and ranges are set using CASSY Lab software.
The 30 A box is used to measure currents between 1 A and 30 A using a Hall sensor element. It connects to CASSY modules via 4 mm safety sockets and can measure both DC and AC currents. When connected, the 30 A box is automatically recognized and measurement quantities and ranges are set using CASSY Lab software.
The 30 A box is used in conjunction with the CASSY com- Input resistance: < 0.05 Ω puter-assisted measurement system. It is used to measure Measurement error: < 2.5 % currents between 1 A and 30 A. The voltage drop is minute Output voltage: max. ± 1V even for very high currents as the 30 A box uses a Hall sensor Connection: 4 mm safety sockets element. Experiment examples are found on the CD of the CASSY Lab 5 Compatibility software (524 200) or in the download version of the software under http://www.ld-didactic.com or in the manual of the The 30 A box can be used in conjunction with the following CASSY Lab software (524 201). CASSY modules: Mobile- Sensor-CASSY Pocket-CASSY 2 Measurement quantities (524 010) (524 006) CASSY (524 009) Measure- CASSY CASSY- Mobile- Measuring CASSY Lab software ment quan- Lab /1/ Display /2/ CASSY With PC range 1.00 or higher version tity (524 200) (524 020) (524 009) CASSY-Display Firmware DC I ! I ±30.00 A /3/ Without firmware 1.00 or ––– 1.00 or higher PC AC I ! I 21.00 A /3/ higher version version /1/ for Sensor-CASSY (524 010), Pocket-CASSY (524 006) or As a member of the CASSY family this box has the following Mobile-CASSY (524 009) at a PC features: /2/ in conjunction with Sensor-CASSY (524 010) • The box can be plugged in at any time. /3/ below 1 A, the box is subject to interference due to noise. • The connected box is recognized automatically. • Measurement quantities and measuring ranges are set 3 Operation using the menu-driven software. - Plug the 30 A box on a CASSY module, and connect it in the circuit as an ammeter. CASSY is a registered trademark of LD Didactic GmbH - Read the measured value.