Product Function Failure Failure Failure Recommended After the action

Detection
mode Cause Detection Action

Occurrence

Criticality

RPN
Severity

New RPN
Method

SeverityNew

occurrence New

detectionNew
battery Store and Lack of Over 9 6 54 Warning 4 216 Incorporating a 2 1 8 16
supply power heating lights and thermal fuse
electric supply Rapid 7 4 28 motor stops 8 224 Fail-safe circuit 1 2 6 12
energy to discharge working system
the motors Over 7 6 42 7 294 Adjust the 6 5 4 120
charging charging device
motors Supplying Vehicle not over 8 5 40 Frequent 4 160 Overload `3 1 5 15
the power moving heating starts and protection relay
to the stops is added to the
wheels circuit
Mechanic 5 4 20 Motor stops 7 140 Change the 2 1 7 14
al failure working bearings
HVAC Thermal Battery and Compress 7 4 28 Cabin 8 224 Check the 4 2 5 40
managemen cabin or failure temperature refrigerant
t temperature will increase
becomes
uncontrollabl Evaporato 6 4 24 7 168 3 1 4 12
e r failure

Suspensi Good Vibration of Shock 5 3 15 Visible leak 8 120 Replace the part 1 1 9 9
on handling road affects absorber marks in
and the driving leak suspension
comfortable Spring 6 3 18 huge 5 90 Use better spring 2 1 6 12
ride failure vibrations material
during the
motion of car
Steering Control the Hard Tie-rod 6 4 20 Steering 7 140 Replace tie-rod 1 1 9 9
system direction of steering socket wheel socket
the car fails becomes
loose