Multistage Pump Curve
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.
SPECIFICATION
Motor Q
Model 3 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
(kW) (m /h)
GVR8 - 20 /1 0.75 10 9.5 9.3 9 8.5 8 7 6
GVR8 - 20 0.75 20 19.5 19 18 17 16 14 13
GVR8 - 30 1.1 30 29.5 28.5 27 25 24 21 19
GVR8 - 40 1.5 41 39.5 38 36 34 32 28 26
GVR8 - 50 2.2 H 52 50 48 45 42 40 36 32
GVR8 - 60 2.2 (m) 62 60 57 54 51 48 43 39
GVR8 - 80 3.0 83 80 77 73 69 65 58 52
GVR8 - 100 4.0 104 100 97 92 87 81 73 65
GVR8 - 120 4.0 124 120 116 111 104 97 87 78
GVR8 - 140 5.5 145 141 136 130 122 113 102 92
GVR8 - 160 5.5 166 161 156 148 139 130 118 106
GVR8 - 180 7.5 187 182 175 167 157 146 134 120
GVR8 - 200 7.5 208 202 195 186 175 163 150 135