Appendix 12.10
Laboratory Schedule
SAMPLING METHOD
For detailed sampling connections, refer to Appendix 12.3 P&IDs
P&ID LEAD SHEET: Dwg. No. QCS/50/00/PR/DR/PI/012 & 012A
P&ID Unit 09: Dwg. No. QCS/.52/09/PR/DR/PI/211, 211A, 211B & 211C
LABORATORY SCHEDULE FOR SULFUR RECOVERY UNIT (UNIT 09) LEGEND: SO: Start up operation A:1/Shift D: 1/Month
NO: Normal operation B:1/Day E: On Request (at least D)
C: 1/Week F: 1/6 hours
* : On-line Analyzer Provided G: 1/4 hours
Page 2 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.3 Age Off Gas from 1) S3-520901 HC C GPA 2261 S3B *52AI090041
52-C0903 2) Downstream 52AP090041 H2S, 0.02 mol % C C* SMS 1318 52-09-PR-
3) P5209038-32” CO2 (Dry basis) 98.42 mol % E ASTM D 5504 DR-PI-211
Page 3 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.7 Process Gas to 52- 1) S-520904 H2S 1.9 mol% E C/E ASTM D 6228-98 S (Note 3) Customized
E0912 2) Outlet of 52-V0911 SO2 0.96 mol% E C/E ASTM D 6228-98 Gaschromatograph
3) P5209008-52” COS 0.15 mol% E E ASTM D 6228-98 With capillary column & PFD
4) 52-09-PR-DR-PI-121 CS2 0.03 mol% E E ASTM D 6228
9.8 Blowdown water from 1) S2-520942 pH E ASTM D 1293 B
52-E0912 2) Blow down water to 52-V9221 Cl– ASTM D 512
3) BD5209003-2” Conductivity ASTM D 1125
4) 52-09-PR-DR-PI-122 PO4 ASTM D 515
SO3 ASTM D4327
Silica ASTM D 859
TDS ASTM D 18880
9.10 Process gas from 1) S-520906 H2S 1.95 mol% E C/E ASTM D 6228-98 S (Note 3) Customized
52-E0913 2) Inlet of 52-V0912 SO2 0.98 mol% E C/E ASTM D 6228-98 Gaschromatograph
3) P5209010-52” With capillary column &
4) 52-09-PR-DR-PI-123 PFD. (Note 2)
9.11 Process gas to 1) S-520907 H2S 0.44 mol% E C/E ASTM D 6228-98 S (Note 3) Customized
52-E0914 2) Outlet of 52-V0912 SO2 0.22 mol% E C/E ASTM D 6228-98 Gaschromatograph
3) P5209013-52” With capillary column &
4) 52-09-PR-DR-PI-123 PFD.
9.12 Process gas from 1) S-520908 H2S 0.44 mol% E C/E ASTM D 6228-98 S (Note 3) Customized
52-E0914 2) Inlet of 52-V0913 SO2 0.22 mol% E C/E ASTM D 6228-98 Chromatograph
3) P5209014-52”
4) 52-09-PR-DR-PI-125
9.13 Process gas to 1) S-520909 H2S 0.44 mol% E C/E ASTM D 6228-98 S (Note 3) Customized
52-F0901 2) Outlet of 52-V0913 SO2 0.22 mol% E C/E ASTM D 6228-98 Chromatograph
3) P5209015-52”
4) 52-09-PR-DR-PI-125
Page 4 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.14 Process Gas from 52- 1) S-520910 H2S 0.43 mol % SMS 2254 S (Note 3) Customized
F0901 2) Inlet to 52-V0901 SO2 0.22 mol % Chromatograph
3) P5209016-64” CO2 37.66 mol % SMS 2254
4) 52-09-PR-DR-PI-130 H2O ASTM D5454
9.15 Process Gas to 52- 1) S-520911 H2S 1.01 mol % SMS 2254 S (Note 3) Customized
E0901 2) Outlet of 52-V0901 SO2 0 Chromatograph
3) P5209019-64” CO2 39.28 mol % SMS 2254
4) 52-09-PR-DR-PI-130 H2O ASTM D5454
9.16 Blow down water to 1) S2-520943 pH E ASTM D 1293 S2
52-V9221 2) Blow down water from 52- Cl– ASTM D 512 52-09-PR-
E0901 Conductivity ASTM D 1125 DR-PI-211A
3) BD5209005-2” PO4 ASTM D 515
4) 52-09-PR-DR-PI-131 SO3 ASTM D 4327
Silica ASTM D 859
TDS ASTM D 18880
9.17 Process Gas from 1) S3-520912 HC 0.24 mol % E* GPA 2261 S3B *52AI090011 (H2s,H2)
52-C0901 2) O/H outlet of 52-C0901 N2 56.04 mol % E SMS 1318 52-09-PR-
3) P5209021-56” H2 3.21 mol % E ASTM D 5504 DR-PI-211
Page 5 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.19 TGT backwash water 1) S5-520922 CO2 SMS 2239 S5
to 52-C0902 2). Discharge from 52-P0910A/B H2S SMS 2239 52-09-PR-
3) SV5209003-6” H2O SMS 1608 DR-PI-211A
4) 52-09-PR-DR-PI-146
9.20 TGT Tail Gas to 52- 1) S3-520913 CO2 38.12 mol % SMS 2239 S3B *52AI090014 (H2S)
X0921 2) O/H from 52-C0902 H2S 0.01 mol % SMS 2239 52-09-PR-
3) P5209024-60” H2O SMS 1608 DR-PI-211A
4) 52-09-PR-DR-PI-147
9.21 TGT rich solution to 1) S6-520933 CO2 14.68 mol % SMS 2239 S6
52-E0906A/C 2) Discharge from 52-P0902A/B H2S 5.89 mol % SMS 2239 52-09-PR-
3) SV5209015-10” H2O SMS 1608 DR-PI-211A
4) 52-09-PR-DR-PI-148
9.22 Blowdown water from 1) S2-520944 pH E ASTM D 1293 S2
52-E0921 2) Blowdown water to 52-V921 Cl–
ASTM D 512 52-09-PR-
3) BD5209007-3” Conductivity ASTM D 1125 DR-PI-211B
Page 6 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.24 Blowdown water from 1) S1-520945 pH E ASTM D 1293 S1
52-E9241 2) Blow down water to 50-T3302 Cl– ASTM D 512 52-09-PR-
3) BD5209141-3” Conductivity ASTM D 1125 DR-PI-211B
4) 52-09-PR-DR-PI-170A
9.27 Rich Acid Gas from 1) S3-520902 CO2 39.61 mol % SMS 2254 S3B *52AI090015 (H2S)
52-V0903 2) Rich Acid Gas to 52-V0914 H2S 60.34 mol % SMS 2254 52-09-PR-
3) AG5209001-28” H2O ASTM D 5454 DR-PI-211B
4) 52-09-PR-DR-PI-171
Page 7 of 8
SAMPLING POINT TESTING ITEM FREQUENCY
&
NORMAL FIGURE
No. STREAM NAME 1) Sampling Type & No. Test Item Normal Figure SO NO TEST METHOD SAMPLING SAMPLE REMARKS
2) Location (Note 1) METHOD CONTAINER
3) Related Line No.
4) Related Dwg No.
9.28 Sour water from the 1) S5-520915 MDEA (ATB) E SMS 2236 S5
discharge of 2) Sour water to 50-V3304 H2S E SMS 2239 52-09-PR-
52-P0904A/B 3) PW5209036-6” CO2 E SMS 2239 DR-PI-211B
4) 52-09-PR-DR-PI-174
Notes:
1) Water & sulfur free.
2) Customized gas chromatograph with column switch, capillary column, FPD detector (flame photometric detector)
& split/splitless injection.
3) Strahman valve or equal, jacketed with 1/2 “ steam & condensate connections.
4) 3B/C = Normally every 3 days unless otherwise specified by authority regulations.
Page 8 of 8