WESSELS COMPANY

Tank Sizing

Plain Steel - Hydro-Pneumatic Tanks

REQUIRED INFORMATION

1. Drawdown (Amount of water tank must supply): 50 GALLONS

2. Minimum Pressure (Pump turn on pressure): 30 PSIG (must be gauge pressure)

3. Maximum Pressure (Pump turn off pressure): 55 PSIG (must be gauge pressure)

TANK SIZING CALCULATIONS

Acceptance Factor: 0.118

Required Tank Volume: 423.89 GALLONS


VOLUME MODEL

10 FXA 35

13 FXA 50

23 FXA 130

35 FXA 200