Professional Documents
Culture Documents
MTC p2045 10000 RP 001 Rev 0 Survey Report
MTC p2045 10000 RP 001 Rev 0 Survey Report
MTC-P2045-10000-RP-001
Prepared for
F T
A
R
D
This report is granted or issued subject to the condition that it is understood and agreed that nothing herein shall be deemed
to relieve any designer, manufacturer, seller, supplier, repairer or operator of any warranty, express or implied and MTC Sdn.
Bhd. liability shall be limited to the acts and omissions of its employees, agents, and subcontractors. Under no
circumstances whatsoever shall MTC Sdn. Bhd. be liable for any injury or damaged to any person or property occurring by
reason of negligent operation, misuse of or any defect in materials, machinery, equipment or other items other than defects
in items actually provided by MTC Sdn. Bhd. and ascertainable by normally accepted standards, or defects reflected in
documents reviewed by MTC Sdn. Bhd. and ascertainable by normally accepted standards, or defects reflected in
documents reviewed by MTC Sdn. Bhd. and which covered by this report.
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 2 of 12
TABLE OF CONTENTS
1.0 INTRODUCTION 3
1.1 PURPOSE 3
1.2 EXECUTIVE SUMMARY 3
3.0 FINDINGS 5
3.1 HEEL 5.4° TO STARBOARD 5
3.2 PLATE BUCKLED AT FLOODING MAIN DECK 7
3.3 GRADE ‘D’ RUST AT MAIN DECK 8
3.4 DAMAGE & CORROSION AT HULL SURFACE 9
4.0
3.5 CORROSION OF FRAME STRUCTURE
F T 10
11
11
A
4.2 SECOND HAND BARGE 12
R
D
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 3 of 12
F T
A
Picture 1: The dredger inclined to starboard
R
D
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 4 of 12
Picture 2: Starboard side main deck flooded (water level reached handrail)
F T
A
R
D
Figure 1: Inclined condition
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 5 of 12
F T
A
R
D
Picture 3: Buckled plate at starboard main deck
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 6 of 12
Most of the main deck surface structure on which mill scale has rusted away.
General pitting is visible under normal condition.
F T
A
Picture 4: Rusted & damaged at walkway
R
D
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 7 of 12
Hull structure above water level was found rusted on the surface around.
F T
A
Picture 6: Rusted hull condition at port side
R
D
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 8 of 12
F T
A
R Picture 8: Tank condition
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.
SURVEY REPORT OF NO. 5 DREDGER
MTC-P2045-10000-RP-001_Rev. 0
Page 9 of 12
F T
A
R
D
This document is the property of MTC Engineering Sdn. Bhd. and shall not be either reproduced or copied in whole or in part or
communicated to any third party without the prior written consent of MTC Engineering Sdn. Bhd.