1-1/4 SUPER FLEX FEEDER CABLE

Description : The 1-1/4 Super flexible cable is manufactured with both inner and outer corrugated copper conductors to give a extra flexibility to the SF cable as compared to standard cable. The inner conductor is insulated with foam dielectric having high degree of foaming. The cable is jacketed with Black LDPE jacketing compound to impart protection against UV rays.

Inner Corrugated Copper Tube LDPE + HDPE Foam Insulation Outer Corrugated copper Conductor Jacket

Product Code : MFLRF114SCCTCPA002

Mechanical Parameters
Inner Conductor Dielectric Diameter Over Outer Conductor Diameter Over Outer Jacket Cable Weight Tensile Strength Minimum Bending Radius , Single Turn Minimum Bending Radius , Repeated Number of Bends , Minimum (Typical) Bending Moment Flat Plate Crush Strength Recommended Hanger Spacing Installation Temperature Range Operating Temperature Range Storage Temperature Range Copper Tube Foam Dielectric Corrugated Copper Tape PE 750 kg/km 1800 N 150 mm 200 mm 15 (50) 30.5 Nm 1.3 Kg/mm 1.0 m -40 to + 60 Deg C -55 to + 85 Deg C -70 to + 85 Deg C
13.55 0.1 mm 33.0 0.2 mm 35.90 0.2 mm 39.40 0.4 mm

Electrical Parameters
Impedance Relative Velocity of Propagation Insulation Resistance Capacitance Inductance Maximum Operating Frequency Cut Off Frequency Peak Power Rating DC Break Down Voltage Jacket Spark , Volts RMS Inner Conductor DC Resistance Outer Conductor DC Resistance Return Loss 800 1000 MHz Return Loss 1700 2200 MHz Return Loss 2200 2700 MHz VSWR 800 1000 MHz VSWR 1700 2200 MHz VSWR 2200 2700 MHz 50 1 88% 10 G x km 79 pF/m 0.179 H/m 3.3 Ghz 3.6 Ghz 180 8500 10000 2.65 /1000m 0.85 /1000m 24.3 dB 24.3 dB 24.3 dB 1.13 1.13 1.13 Frequency MHz 100 200 300 400 450 600 700 800 890 960 1000 1500 1700 1800 2000 2100 2200 2300 2500 2700 3000 Attenuation dB/100 M 0.89 1.24 1.57 1.86 2.01 2.31 2.57 2.76 2.98 3.07 3.15 3.98 4.31 4.49 4.79 4.90 5.08 5.20 5.41 5.69 6.19 Peak Power Rating 10.44 7.50 5.92 5.00 4.62 4.02 3.62 3.37 3.12 3.03 2.95 2.34 2.16 2.07 1.94 1.90 1.83 1.79 1.72 1.63 1.50

# Attenuation at 20 Deg C # # Attenuation values are exclusive of connector loss


Rev date : 01/09/2010