Professional Documents
Culture Documents
l ρ d % n w r L V V: Datos a ingresar unidades Pipe 1 Pipe 2
l ρ d % n w r L V V: Datos a ingresar unidades Pipe 1 Pipe 2
l ρ d % n w r L V V: Datos a ingresar unidades Pipe 1 Pipe 2
7 w 8 r 9 L 10 11 Vdv 12 V.085
Pipe diameter Pipe length Soil resistivity current density Coating efficiency Lifetime (years) Type of Anode Anode weight Anode radiuos Anode Length driving voltage Polarised steel
unidades Pipe 1 in 2 m 300 .cm 4500 mA/m2 9 % 50% years 20 choose Mg1 pon 9 cm 8.89 cm 53.54 mV 1.56 mV 0.85
step 7
Distribution Area
m2
2.47
Layout Ac Ac/A
effective surface Number of Anode m2 # anode 23.94 9.71 51.87 21.04
total anodes
30.75
ITEM Mg1
ANODES material Mg
weight pon 9
radiuos cm 8.89
Length cm 53.54
4 besitos
Datos a ingresar 1 l 2 3 d 4 % 5 n 6
7 w 8 r 9 L 10 11 Vdv 12 V.085
Pipe diameter Pipe length Soil resistivity current density Coating efficiency Lifetime (years) Type of Anode Anode weight Anode radiuos Anode Length driving voltage Polarised steel Coating impedance Maximum Groundbed resistance Spacing Anode Cross section Current Limit
unidades Pipe 1 in 6 m 2072 .cm 2000 mA/m2 30 % 50% years 15 xdefinir pon 110 cm 12.7 cm 20.32 NA NA .m2 25000 2 m 9.14 m2 0.37 A/m2 10.76
Pipe 2
m2 m2 A
0 0 0
step 6
Rg
Groundbed resistance
Rectifier specification
step 7
Vrec Srec
Volt Watt
19.51 290.31
Specification 20VDC
290W
ITEM Mg1