Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 31

DR.M.S.

SOLIMAN

Job No.

ENGINEERING OFFICE

Project I.D.

Building No.

Rev.No.
Date:

TEL:22637248

Description

0.883 Designed By:

01

TAMER

Checked By:

18 MAHMOUD SHALTOUT ST.,NASER CITY,CAIRO,EGYPT

Econmic Flange
For Given Depth

DESIGN
OFOFSTEEL
RAFTER
DESIGN
STEEL RAFTER
APPLIED FORCES

Province.No.

Mx
N
Qy

320.0 (t.cm)
-30.000 (ton)
2.96 (ton)

My
Side sway permited

0 (t.cm)
yes

SECTION DIMENSION (in cm)


bft
bfb
tsu
tsb
Bw
K
T
MEMBER LENGTH
SECTION PROPERTIES

16 Fu
16
0.7 Cb
0.7 T used in stiffness
0.71 Cmx
0 Always enter K=0
30 C
400.0 Cmy

Y elastic ( from Bottom)

5 wind
U ( Tension)
1.130 FY

xxx
1
3.5
30

0.85
t
0.9 b
0.85

1.6
0.9
0.9

15.000 (cm)

Ix
Ix For Stiffness
Iy
Iy For Stiffness
ix

6192.583 (cm4)
6192.583 (cm4)
478.720 (cm4)
478.720 (cm4)
12.042 (cm2)

AF

11.200 (cm2)

RT

4.049 (cm)

area

42.706 (cm2)

iy
sy
Zy
d

3.349 (cm2)
59.840 (cm3)
93.204 (cm3)
28.600 (cm)

Y Pastic ( from Bottom)

15.000 cm

Zxc Plastic (top)

473.348 cm3

Zxt Plastic ( Bottom)

473.348 cm3

7.071 cm4

Cw

102560.939 cm6

Sxc

412.839 cm3

Sxt

412.839 cm3

Iyc

3211.051 cm4

Iyc/Iy

Lu (lateral torsional
buckling Length)

6.708

400 (cm)

CHECK ON WEB SLENDERNESS IN BENDING


top
hc
hp
p
r
web

-1.441
t/cm2
28.60
cm
28.60
cm
hc/hp*SQRT(2100/FY)/(0.54*Mp/My-0.09)^2
5.7*SQRT(2100/FY)
40.28

bot

0.036
top/ bot
87.483
139.621

compact Web

Page 1

t/cm2
-0.025
Table B4.1
Table B4.1

DR.M.S.SOLIMAN

Job No.

ENGINEERING OFFICE

Project I.D.

Building No.

Rev.No.
Date:

TEL:22637248

Description

0.883 Designed By:

01

TAMER

Checked By:

18 MAHMOUD SHALTOUT ST.,NASER CITY,CAIRO,EGYPT

Axial Force Criteria


Xo
Yo

0.00
0.00

ro2
H

Xo2+Yo2+(Ix+Iy)/Ag
1-(Xo2+Yo2)/ro2

Fex
Fez
Fe ( torsional Buckling)
Fe (flexural buckling)
Fe (controlling)
Fcr
be
Qa

3.142*E/(Kx L/rx)2
29.32 Fey
(3.142 E Cw/(Kz L)2 + GJ)*1/(Ag*ro2)
(Fey+Fez)/(2H)*(1-sqrt(1-4 Fey Fez H/(Fey+Fez)2))
3.142*E/(maxK L/r)2
min(Fe (flexural buckling);Fe ( torsional Buckling))
0.877*Fe
d
Aeff/A

Fcr
Pn

0.877*Fe
AREA*Fcr

3.142*E/(Ky L/ry)2
2.808
1.451
1.451
1.451
1.273
28.600
1
1.273
54.359

156.215
1
1.451
t/cm2
t/cm2
t/cm2
t/cm2
t/cm2
cm

E4-7
E4-8
E4-9,E4-10
E4-10
E4-5
E3-4
E3-2 or E3-3
E7-17
E7-16

t/cm2
tons

CHECK ON STABILITY OF TOP FLANGE (bending)


Kc
LEFT

0.630
-1.4414

Right

p
r

0.38*SQRT(2100/FY
0.64*SQRT(Kc*2100/FY)

9.308
22.08

Flange

11.4286

Qs

-1.441426
Table B4.1
Table B4.1
non-Compact flange

E7-7 or E7-8

CHECK ON STABILITY OFBOTTOM FLANGE(bending)

Kc

0.76

LEFT
p
r

0.04
0.38*SQRT(2100/FY
0.95*SQRT(Kc*2100/0.7/FY)

Flange

11.4286

Qs

or E7-9

Right
9.308
24.25

0.04
Table B4.1
Table B4.1
non-Compact flange

E7-7 or E7-8
or E7-9

Bending Moment Criteria


1-Compression Flange Yielding
Fl
aw

0.7*FY
MIN(hc*Bw/bft/tsu,10)

2.45
1.81

Lp

1.1*RT*SQRT(2100/FY)

109.1

cm

Lr

1.95*RT*2100/FL*SQRT(J/Sxc/d)*SQRT(1+SQRT(
1+6.76*(FL*Sxc*d/2100/J)^2))

411.14

cm

Rpc

Mp/Myt

Mn

Rpc*FY*Sxc

t/cm2

Table B4.1
F4-11
F4-7

F4-8 or F5-5
1.15
1656.72

t.cm

F4-15b or F5-6
F4-1 or F5-1

NA

F5-3

2-Lateral_torsional Buckling
For Lp <Lb <= Lr
Mn

For Lb > Lr
Mn
Lp < Lb <= Lr
Mn
3-Local Flange Buckling
Mn

Fcr

NA

MIN(Cb*(Rpc*Myc-(Rpc*Myc-Fl*Sxc)*(Lu-Lp)/(LrLp)),Rpc*Myc)

Fcr
MIN(Fcr*Sxc,Rpc*FY*Sxc)

(Cb*3.14^2*2100/
(Lu/RT)^2*SQRT(1+0.078
*J/Sxc/d*(Lu/RT)^2))

D116*FY*E50-(D116*FY*E50-D112*E50)*(B97-C95)/(C96-C95)

Page 2

1169.84

t.cm

2.89
1194.19

t.cm

1169.84

t.cm

1549.59

t.cm

F4-2 or F5-2

F4-5 or F5-3

F4-12 or F4-13

DR.M.S.SOLIMAN

Job No.

ENGINEERING OFFICE

Project I.D.

Building No.

Rev.No.
Date:

TEL:22637248

Description

0.883 Designed By:

01

TAMER

Checked By:

18 MAHMOUD SHALTOUT ST.,NASER CITY,CAIRO,EGYPT

or F5-8 or F5-9
4-tension flange yeilding
Mn

NA

Callculation of Flexural Buckling lengths


Gl
Gu

0.1 Run
0.1 Kx

Lx
x=Lx/ix

for (K)
0.8

320 (cm)
26.57 y=Ly/iy

Mnx
Mny
Pn
Mcx
Mcy
Pc

0.5PR

Ly

400 (cm)
119.44

1169.84
296.4
54.36
1052.86
266.76
48.92

Fbcx (the allowable bending stresses about the X-axis)


B1x
Cmx/(1-alpha*Pr/Pel)
B1y
Cmy/(1-alpha*Pr/Pel)

t.cm
t.cm
tons
t.cm
t.cm
tons

0.88 IF B1< 1 ,take B1


3.77 IF B1< 1 ,take B1

74.74 OK

check on Unity
Unity Equaion

t.cm

0.883 O.k

Pr/Pc+8/9(Mrx/Mcx+Mry/Mcy)

Page 3

1
3.77

C2-2
C2-2

Element Forces - Frames

sap9 input data

Check Sections

Create detailed
Design Files

Page 18

Element Forces - Frames

Page 19

Frame Props 01 - General

Page 20

Frame Props 01 - General

Page 21

Frame Props 01 - General

Page 22

Frame Props 01 - General

Page 23

Frame Props 01 - General

Page 24

Frame Props 01 - General

Page 25

Frame Section Assignments

Page 26

Frame Props 05 - Nonprismatic

Page 27

Frame Props 05 - Nonprismatic

Page 28

Connectivity - Frame

Page 29

Sheet9

Page 30

Sheet9

Page 31

You might also like