Professional Documents
Culture Documents
Reference Description of Problem Values Units: Infomile Solutions
Reference Description of Problem Values Units: Infomile Solutions
Client: S.V.POWER PVT LTD Project: 500 TPH CFBC BOILER Job Title: Design of Footing Building: COMPRESSOR BUILDING Date: Done by: Checked by: 15.09.2008 AKV Rev: M25 Fe500 fck fy 0
Reference
Description of Problem
Grade of Concrete Grade of Steel Unit Weight of Soil Safe Bearing Capacity of soil, SBC Depth of Pedestal Width of Pedestal Length of Pedestal above footing Length of Footing Width of Footing Area of Footing Depth of Footing Effective Cover to Steel Effective depth Moment of inertia about x, Moment of inertia about z, Weight of soil above footing Weight of Footing GOVERNING LOAD CASES NORMAL LOADS(DL+IL) Pi Mxi Mzi DL+IL+EQX Pii Mxii Mzii DL+IL+EQZ Piii Mxiii Mziii NORMAL LOADS(DL+IL) Pi/A Mxi/Zxx Mzi/Zzz Pmaxi Pmini SINCE Pmaxi<SBC, SIZE PROVIDED IS SAFE DL+IL+EQX Pii/A Mxii/Zxx Mzii/Zzz Pmaxii Pminii SINCE Pmaxii<1.25SBC, SIZE PROVIDED IS SAFE DL+IL+EQZ Piii/A Mxiii/Zxx Mziii/Zzz Pmaxiii Pminiii SINCE Pmaxiii<1.25SBC, SIZE PROVIDED IS SAFE
Values Units
25.00 MPa 500.00 MPa 18.00 kN 600.00 kN/m2 0.60 m 0.30 m 2.70 m 1.50 m 1.20 m 1.80 m2 0.40 m 0.06 m 0.34 m 0.45 m3 0.36 m3 78.73 kN 18.00 kN
X Z
369.82 kN 8.53 kNm 5.88 kNm 392.16 kN 7.94 kNm 36.04 kNm 388.82 kN 8.02 kNm 30.50 kNm
259.20 kN/m2 18.96 kN/m2 16.33 kN/m2 294.49 kN/m2 223.91 kN/m2
271.61 kN/m2 17.64 kN/m2 100.10 kN/m2 389.35 kN/m2 153.86 kN/m2
269.75 kN/m2 17.82 kN/m2 84.73 kN/m2 372.30 kN/m2 167.20 kN/m2
file:///opt/scribd/conversion/tmp/scratch29580/65552165.xls
InfoMile Solutions
Client: S.V.POWER PVT LTD Project: 500 TPH CFBC BOILER Job Title: Design of Footing Building: COMPRESSOR BUILDING Date: Done by: Checked by: 15.09.2008 AKV Rev: 0
Reference
Description of Problem
Values Units
371.71
1.20 171.50
251.93
287.57
274.21
Moments at the face of Pedestal: Moment about X-direction Mxu/bd2 (Mxu = 1.5*Mx) Percent of Steel required Area of steel required/m Provided Diameter of bar # 12 Spacing required Check for max. spacing Provide #12mm bars @ 200mm Moment about Z-direction (Mzu = 1.5*Mz) Mzu/bd2 Percent of Steelrequired Area of steel required/m Provided Diameter of bar # 12 Spacing required Check for max. spacing Provide #12mm bars @ 200mm Check for Shear: Pr. at d diatance from face 284.30 Shear For both directions 29.49 Maximum Shear Force v = Vu/bd (Vu = 1.5*V) Available steel Area Percent of steel provided For the above % of steel Design Shear strength
Mx pt Ast
35.61 kNm 0.46 MPa 0.12 % 408.00 mm2 4.00 250.00 mm 250.00 mm
Mz pt Ast
28.67 kNm 0.37 MPa 0.12 % 408.00 mm2 4.00 250.00 mm 250.00 mm
kN/m2 kN V v
357.03 kN/m2 33.07 kN 33.07 kN 0.15 MPa 565.49 mm2 0.17 % 0.35 MPa
Table 19 of IS:456-2000
file:///opt/scribd/conversion/tmp/scratch29580/65552165.xls
InfoMile Solutions
Client: S.V.POWER PVT LTD Project: 500 TPH CFBC BOILER Job Title: Design of Footing Building: COMPRESSOR BUILDING Date: Done by: Checked by: 15.09.2008 AKV Rev: 0
Reference
Description of Problem
Punching Shear Punching Resistance Punching resistance is >
Values Units
895.33 kN 392.16 kN
file:///opt/scribd/conversion/tmp/scratch29580/65552165.xls