Professional Documents
Culture Documents
LSCFG VP
LSCFG VP
LSCFG VP
U78A0.001.DNWH9AG-P1
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FFE01212
Device Specific.(Z5)........02E82752
Device Specific.(Z6)........06E12715
Device Specific.(Z7)........07E12752
Device Specific.(Z8)........20000000C98B1E8F
Device Specific.(Z9)........ZS2.71A2
Device Specific.(ZA)........Z1F2.70A5
Device Specific.(ZB)........Z2F2.71A2
Device Specific.(ZC)........00000000
Hardware Location Code......U78A0.001.DNWH9AG-P1-C3-T2
fcnet3
U78A0.001.DNWH9AG-P1-C3-T2
Fibre Channel Network Protocol Device
fscsi3
U78A0.001.DNWH9AG-P1-C3-T2
FC SCSI I/O Controller Protocol Device
pci3
U78A0.001.DNWH9AG-P1
PCI Bus
Hardware Location Code......U78A0.001.DNWH9AG-P1
fcs0
FC Adapter
U78A0.001.DNWH9AG-P1-C5-T1
Part Number.................10N8620
Serial Number...............1C905081E4
Manufacturer................001C
EC Level....................D76625
Customer Card ID Number.....5759
FRU Number.................. 10N8620
Device Specific.(ZM)........3
Network Address.............10000000C9849E58
ROS Level and ID............02C8277A
Device Specific.(Z0)........1036406D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FFC01231
Device Specific.(Z5)........02C8277A
Device Specific.(Z6)........06C12715
Device Specific.(Z7)........07C1277A
Device Specific.(Z8)........20000000C9849E58
Device Specific.(Z9)........BS2.71X10
Device Specific.(ZA)........B1F2.70A5
Device Specific.(ZB)........B2F2.71X10
Device Specific.(ZC)........00000000
Hardware Location Code......U78A0.001.DNWH9AG-P1-C5-T1
fcnet0
U78A0.001.DNWH9AG-P1-C5-T1
Fibre Channel Network Protocol Device
fscsi0
U78A0.001.DNWH9AG-P1-C5-T1
FC SCSI I/O Controller Protocol Device
hdisk2
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L0
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk3
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L1000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk4
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L2000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk5
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L3000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk6
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L4000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk7
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L5000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk8
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L6000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
hdisk9
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L7000000000000
MPIO Other DS4K Array Disk
Manufacturer................IBM
Machine Type and Model......1814
FAStT
ROS Level and ID............30393136
Serial Number...............
Device Specific.(Z0)........0000053245004032
Device Specific.(Z1)........
dac0
U78A0.001.DNWH9AG-P1-C5-T1-W202600A0B850E000-L1F000000000000
DS3/4K PCM User Interface
dac1
U78A0.001.DNWH9AG-P1-C5-T1-W202700A0B850E000-L1F000000000000
DS3/4K PCM User Interface
fcs1
U78A0.001.DNWH9AG-P1-C5-T2
FC Adapter
Part Number.................10N8620
Serial Number...............1C905081E4
Manufacturer................001C
EC Level....................D76625
Customer Card ID Number.....5759
FRU Number.................. 10N8620
Device Specific.(ZM)........3
Network Address.............10000000C9849E59
ROS Level and ID............02C8277A
Device Specific.(Z0)........1036406D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FFC01231
Device Specific.(Z5)........02C8277A
Device Specific.(Z6)........06C12715
Device Specific.(Z7)........07C1277A
Device Specific.(Z8)........20000000C9849E59
Device Specific.(Z9)........BS2.71X10
Device Specific.(ZA)........B1F2.70A5
Device Specific.(ZB)........B2F2.71X10
Device Specific.(ZC)........00000000
Hardware Location Code......U78A0.001.DNWH9AG-P1-C5-T2
fcnet1
U78A0.001.DNWH9AG-P1-C5-T2
Fibre Channel Network Protocol Device
fscsi1
U78A0.001.DNWH9AG-P1-C5-T2
FC SCSI I/O Controller Protocol Device
vio0
Virtual I/O Bus
vsa1
U78A0.001.DNWH9AG-P1-T2
LPAR Virtual Serial Adapter
Hardware Location Code......U78A0.001.DNWH9AG-P1-T2
vty1
U78A0.001.DNWH9AG-P1-T2-L0
Asynchronous Terminal
vsa0
U78A0.001.DNWH9AG-P1-T1
LPAR Virtual Serial Adapter
U78A0.001.DNWH9AG-P1
U78A0.001.DNWH9AG-P1-C2
U78A0.001.DNWH9AG-P1-C2
U78A0.001.DNWH9AG-P1-C2
Manufacture ID..............YL1026
FRU Number..................46Y3512
Network Address.............00145EE7D2A7
ROM Level.(alterable).......CL0140
Hardware Location Code......U78A0.001.DNWH9AG-P1-C2-T3
ent3
U78A0.001.DNWH9AG-P1-C2-T4
4-Port 10/100/1000 Base-TX PCI-Express Adapter (14106803)
4-P NIC-SX PCI-e:
EC Level....................D76641
Part Number.................46Y3512
Manufacture ID..............YL1026
FRU Number..................46Y3512
Network Address.............00145EE7D2A6
ROM Level.(alterable).......CL0140
Hardware Location Code......U78A0.001.DNWH9AG-P1-C2-T4
pci4
PCI Express Bus
U78A0.001.DNWH9AG-P1
U78A0.001.DNWH9AG-P1
Hardware Location Code......U78A0.001.DNWH9AG-P1
sisscsia0
U78A0.001.DNWH9AG-P1-C4
PCI-X Dual Channel Ultra320 SCSI Adapter
Hardware Location Code......U78A0.001.DNWH9AG-P1-C4
scsi0
U78A0.001.DNWH9AG-P1-C4-T1
PCI-X Dual Channel Ultra320 SCSI Adapter bus
ROM Level.(alterable).......0708000b
Customer Card ID Number.....5702
rmt1
U78A0.001.DNWH9AG-P1-C4-T1-L4-L0
Other SCSI Tape Drive
Manufacturer................IBM
Machine Type and Model......ULT3580-TD2
Serial Number...............
Device Specific.(Z3)........0000
scsi1
U78A0.001.DNWH9AG-P1-C4-T2
PCI-X Dual Channel Ultra320 SCSI Adapter bus
ROM Level.(alterable).......0708000b
Customer Card ID Number.....5702
pci1
PCI Bus
U78A0.001.DNWH9AG-P1
Hardware Location Code......U78A0.001.DNWH9AG-P1
usbhc0
U78A0.001.DNWH9AG-P1
USB Host Controller (33103500)
U78A0.001.DNWH9AG-P1
Hardware Location Code......U78A0.001.DNWH9AG-P1
sissas0
U78A0.001.DNWH9AG-P1-T9
PCI-X266 Planar 3Gb SAS Adapter
ROM Level.(alterable).......03200048
Customer Card ID Number.....572C
Hardware Location Code......U78A0.001.DNWH9AG-P1-T9
sas0
U78A0.001.DNWH9AG-P1-T9
Controller SAS Protocol
ses0
U78A0.001.DNWH9AG-P2-Y1
SAS Enclosure Services Device
ROM Level.(alterable)....... 01
Hardware Location Code......U78A0.001.DNWH9AG-P2-Y1
rmt0
U78A0.001.DNWH9AG-P2-D1
SAS 4mm Tape Drive (36000 MB)
Manufacturer................IBM
Machine Type and Model......DDS Gen5
Device Specific.(Z1)........BS10
Serial Number...............20960612
Load ID.....................A1700D65
Part Number.................23R2528
FRU Number..................23R2530
EC Level....................H82070
Device Specific.(Z0)........0180030283001000
Device Specific.(Z3)........L1
Hardware Location Code......U78A0.001.DNWH9AG-P2-D1
hdisk0
U78A0.001.DNWH9AG-P2-D3
SAS Disk Drive (300000 MB)
Manufacturer................IBM
Machine Type and Model......HUS154530VLS300
FRU Number..................10N7234
ROS Level and ID............41353730
Serial Number...............JLW152YC
EC Level....................L80304J
Part Number.................42R5648
Device Specific.(Z0)........000005329F001002
Device Specific.(Z1)........V3IPA570
Device Specific.(Z2)........0068
Device Specific.(Z3)........09155
Device Specific.(Z4)........
Device Specific.(Z5)........22
Device Specific.(Z6)........L80304J
Hardware Location Code......U78A0.001.DNWH9AG-P2-D3
hdisk1
U78A0.001.DNWH9AG-P2-D6
SAS Disk Drive (300000 MB)
Manufacturer................IBM
Machine Type and Model......HUS154530VLS300
FRU Number..................10N7234
ROS Level and ID............41353730
Serial Number...............JLW0WJEC
EC Level....................L80304J
Part Number.................42R5648
Device Specific.(Z0)........000005329F001002
Device Specific.(Z1)........V3IPA570
Device Specific.(Z2)........0068
Device Specific.(Z3)........09155
Device Specific.(Z4)........
Device Specific.(Z5)........22
Device Specific.(Z6)........L80304J
Hardware Location Code......U78A0.001.DNWH9AG-P2-D6
sata0
U78A0.001.DNWH9AG-P1-T9
Controller SATA Protocol
cd0
U78A0.001.DNWH9AG-P2-D2
SATA DVD-RAM Drive
Manufacturer................IBM
Machine Type and Model......RMBO0040502
ROS Level and ID............SA63
Device Specific.(Z0)........058002028F000030
Part Number.................44V4219
EC Level....................H89634
FRU Number..................44V4220
Hardware Location Code......U78A0.001.DNWH9AG-P2-D2
lhea0
U78A0.001.DNWH9AG-P1
Logical Host Ethernet Adapter (l-hea)
Hardware Location Code......U78A0.001.DNWH9AG-P1
ent7
U78A0.001.DNWH9AG-P1-C6-T4
Logical Host Ethernet Port (lp-hea)
IBM Host Ethernet Adapter:
Network Address.............00215E774AB1
ent6
U78A0.001.DNWH9AG-P1-C6-T3
Logical Host Ethernet Port (lp-hea)
IBM Host Ethernet Adapter:
Network Address.............00215E774AB0
ent5
U78A0.001.DNWH9AG-P1-C6-T2
Logical Host Ethernet Port (lp-hea)
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................46K7023
Part Number.................46K7696
Power.......................2A00000000000000
Product Specific.(HE).......0001
Product Specific.(CT).......40F30023
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1
QUAD ETHERNET :
Record Name.................VINI
Flag Field..................XXET
Hardware Location Code......U78A0.001.DNWH9AG-P1-C6
Customer Card ID Number.....1819
Serial Number...............YL13W9071012
CCIN Extender...............1
Product Specific.(VZ).......04
FRU Number..................10N9622
Part Number.................10N9623
Product Specific.(HE).......0001
Product Specific.(CT).......40910006
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B1).......00215E774AA00020
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1-C6
ANCHOR
:
Record Name.................VINI
Flag Field..................XXAV
Hardware Location Code......U78A0.001.DNWH9AG-P1-C9
Customer Card ID Number.....52AE
Serial Number...............YL107996K00F
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................10N8696
Part Number.................10N8696
Power.......................8100300000000000
Product Specific.(HE).......0010
Product Specific.(CT).......40B40000
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......43539170030055E549B65350A04285CBE7483DF34D
31519971EA8C8C42B84D32A27BE9FA1C68B4464D33
2704AA177E8539044D3492DC8CB65EB76ED0
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1-C9
THERMAL PWR MGMT:
Record Name.................VINI
Flag Field..................XXTP
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P8030
Part Number.................77P8030
Power.......................4400000000000000
Size........................2048
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1-C13-C4
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWH9AG-P1-C13-C7
Customer Card ID Number.....31AC
Serial Number...............YLD00548179C
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P8030
Part Number.................77P8030
Power.......................4400000000000000
Size........................2048
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1-C13-C7
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWH9AG-P1-C13-C9
Customer Card ID Number.....31AC
Serial Number...............YLD007481799
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P8030
Part Number.................77P8030
Power.......................4400000000000000
Size........................2048
Version.....................ipzSeries
Physical Location: U78A0.001.DNWH9AG-P1-C13-C9
2 WAY PROC CUOD :
Record Name.................VINI
Flag Field..................XXPF
Hardware Location Code......U78A0.001.DNWH9AG-P1-C14
Customer Card ID Number.....252F
Serial Number...............YL107896K01B
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................07P6793
Part Number.................46K7060
Power.......................3300200100038000
Product Specific.(HE).......0001
Product Specific.(CT).......40170202
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......435391421248580D33A353502EE8B6F96841897D4D
31F6737B513F1D34544D32375F2D55878700B84D33
4E3F816BA7A536514D3419220D45346B61EA
Version.....................ipzSeries
Serial Number...............YL14W915901J
FRU Number.................. 46K6926
Part Number.................46K7120
CCIN Extender...............1
Product Specific.(VZ).......01
Product Specific.(B2).......5005076C0DBFC7000000000000000000
Version.....................RS6K
Physical Location: U78A0.001.DNWH9AG-P2
System Firmware:
Code Level, LID Keyword.....Phyp_1 00062009102880A00701
Code Level, LID Keyword.....PFW 17112009102781CF0681
Code Level, LID Keyword.....FSP_Ker 20182009111081E00100
Code Level, LID Keyword.....FSP_Fil 20242009111081E00101
Code Level, LID Keyword.....FipS_BU 20242009111081E00200
Code Level, LID Keyword.....SPCN3 124620060531A0E00A11
Code Level, LID Keyword.....SPCN1 183020070213A0E00D00
Code Level, LID Keyword.....SPCN2 183420070213A0E00D20
Microcode Image.............EL350_039 EL340_075 EL350_039
Hardware Location Code......U8204.E8A.06AF334-Y1
Physical Location: U8204.E8A.06AF334-Y1
Name: openprom
Model: IBM,EL350_039
Node: openprom
Name: interrupt-controller
Model: IBM, Logical PowerPC-PIC, 00
Node: interrupt-controller@0
Device Type: PowerPC-External-Interrupt-Presentation
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000200
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000201
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000202
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000203
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000204
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000205
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000206
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: interrupt-controller
Model: IBM,Logical PHB
Node: interrupt-controller@800000025000207
Device Type: PowerPC-LSI-Source
Physical Location: U78A0.001.DNWH9AG-P1
Name: lhea
Node: lhea@23c00100
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000200
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000201
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000202
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000203
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000204
Device Type: pciex
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000205
Device Type: pciex
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000206
Device Type: pciex
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci
Model: IBM,Logical_PHB
Node: pci@800000020000207
Device Type: pciex
Physical Location: U78A0.001.DNWH9AG-P1
Name: vty
Node: vty@30000000
Device Type: serial
Physical Location: U78A0.001.DNWH9AG-P1-T1
Name: vty
Node: vty@30000001
Device Type: serial
Physical Location: U78A0.001.DNWH9AG-P1-T2
Name: ethernet
Node: ethernet@23e00000
Device Type: network
Physical Location: U78A0.001.DNWH9AG-P1-C6-T1
Name: ethernet
Node: ethernet@23e00100
Device Type: network
Physical Location: U78A0.001.DNWH9AG-P1-C6-T2
Name: ethernet
Node: ethernet@23e01000
Device Type: network
Physical Location: U78A0.001.DNWH9AG-P1-C6-T3
Name: ethernet
Node: ethernet@23e01100
Device Type: network
Physical Location: U78A0.001.DNWH9AG-P1-C6-T4
Name: pci1014,02BD
Node: pci1014,02BD@1
Physical Location: U78A0.001.DNWH9AG-P1-T9
Name: usb
Node: usb@1
Physical Location: U78A0.001.DNWH9AG-P1
Name: usb
Node: usb@1,1
Physical Location: U78A0.001.DNWH9AG-P1
Name: usb
Node: usb@1,2
Physical Location: U78A0.001.DNWH9AG-P1
Name: pci1069,b166
Node: pci1069,b166@1
Physical Location: U78A0.001.DNWH9AG-P1-C4
PCI-X Dual Channel Ultra320 SCSI Adapter:
Part Number.................44V3315
FRU Number..................44V3315
Serial Number...............YL1189190165
Manufacture ID..............0018
EC Level....................1
ROM Level.(alterable).......0708000b
Product Specific.(Z0).......5702
Hardware Location Code......U78A0.001.DNWH9AG-P1-C4
Name: fibre-channel
Model: LP11002
Node: fibre-channel@1
Device Type: fcp
Physical Location: U78A0.001.DNWH9AG-P1-C5-T1
Name: fibre-channel
Model: LP11002
Node: fibre-channel@1,1
Device Type: fcp
Physical Location: U78A0.001.DNWH9AG-P1-C5-T2
Name: pci
Node: pci@0
Device Type: pciex
Physical Location: U78A0.001.DNWH9AG-P1-C2
Name: fibre-channel
Model: LPe11002
Node: fibre-channel@0
Device Type: fcp
Physical Location: U78A0.001.DNWH9AG-P1-C3-T1
Name: fibre-channel
Model: LPe11002
Node: fibre-channel@0,1
Device Type: fcp
Physical Location: U78A0.001.DNWH9AG-P1-C3-T2
Name: hub
Node: hub@1
Physical Location: U78A0.001.DNWH9AG-P1
Name: hub
Node: hub@1
Physical Location: U78A0.001.DNWH9AG-P1-T4
Name: hub
Node: hub@1
Physical Location: U78A0.001.DNWH9AG-P1
Name: scsi
Node: scsi@0
Device Type: scsi-2
Physical Location: U78A0.001.DNWH9AG-P1-C4-T1
Name: scsi
Node: scsi@1
Device Type: scsi-2
Physical Location: U78A0.001.DNWH9AG-P1-C4-T2
Name: pci
Node: pci@2