Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
UTRAN Structure
CN
RNC
RNC
NodeB
NodeB
NodeB
NodeB
UE
OMC-B
SGSN
RNC
OMC-R
RNC
UE
NodeB
Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
Iu CN
Access
Iur RNC
Unit
Switchi ng Unit
Iub
NodeB
provides a large-capacity and non-blocking IP switching unit for system control management, communication between service processing boards and traffic connection among multiple Access units
PWRFAN
STM-1
E1
10/100M Ethernet
RS485
O&M unit
ROMB : RNC Operation & Mentanence Board
Responsible for global process handling of RNC. Responsible for O&M proxy of whole RNC. Managing states of each board, collecting information about each board, and maintaining global static data of whole RNC. Running RPU module to process routing protocol.
Access unit
DTB : Digital Trunk Board
DTB is used to provide E1 interface, and it also supports T1 interface by changing configuration. One of the DTB board provides 32*E1.
Access unit
APBE : ATM Process Board Enhanced
Providing ATM interface of 4STM-1; Supporting 622M switching capacity and completing AAL2 and AAL5 termination of STM-1 physical interface in RNC;
GIPI : GE IP Interface
GIPI provides FE, and GE interfaces and accomplishing IP interface function. 1*GE optical or electrical interface or 4*100M FE electrical interface
Access Unit
EIPI : E1 IP Interface
EIPI provides the IP access based on E1 (working with DTB and SDTB). EIPI do not have the external interfaces itself. One EIPI and two DTB work together, providing at most sityfour E1 interfaces. One EIPI and two SDTB work together, providing one STM-1 interface.
maximum 40G switching capacity responsible for user plane data switching and converging.
Processing unit
Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
Power supply
Cooling fan subrack
Cable tray
CE
19 inch standard rack One rack includes four layer subracks, and one subrack includes seventeen slots
Dust coverage
ZXWR RNC
Dimension:2000600800mm
Uses BCTC as Backboard ,takes charge of processing RNC control plane (RCB&RSB), and also includes ROMP,CLKG,CHUB. CHUB has the function of Switching data.
Uses BUSN as Backboard,takes charge of processing RNC user plane (RUB) and includes GIPI, APBE. If there are more than two resource subracks, switch subrack is needed to switch data. Uses BPSN as Backboard,takes charge of level 1switch , supplies switch unit for user plane.
Resource subrack
Switch subrack
Interface subrack
Uses BUSN as Backboard ,supplies kinds of interfaces, such as E1,STM-1,channelized STM1,POS and so on.
2
R C B
3
R C B
4
R C B
5
R C B
6
R C B
7
R C B
8
R C B
9
U I M C
10
U I M C
11
R O M B
12
R O M B
13
C L K G
14
C L K G
15
C H U B
16
C H U B
17
Board function
RCB:RNC control board, process the signal of Iux and Uu. UIMC: Universal Interface Module of Control, realize the Ethernet switch among the subracks. ROMB:RNC Operating & Maintenance Board CLKG: Clock Generator, supply the system clock CHUB: Control HUB, converge the control signal among the resource subracks.
3
A P B E
4
A P B E
5
R U B
6
R U B
7
R U B
8
R U B
9
G U I M
10
G U I M
11
G I P I
12
G I P I
13
R U B
14
R U B
15
R U B
16
R U B
17
G I P I
Board function
RUB:RNC User Board, process the protocol of user plane. GIPI:GE IP Interface ,provide FE, and GE interfaces APBE:ATM process board enhanced version, provide STM-1, STM-4 interface SBCX: O&Munit, storing log, storing performance data GUIM: Universal Interface Module of BUSN, realize the Ethernet switch among the subracks
2
G L I
3
G L I
4
G L I
7
P S N
8
P S N
10
11
12
13
14
15
U I M C
16
U I M C
17
Board function
GLI: Gigabit Line Interface, adapt physical layer, process IP packet and manage traffic volume PSN: Packet switch network, manage core switch. UIMC: Universal Interface Module of Control, realize the Ethernet switch among the subracks
Board function
APBE : ATM process board enhanced version, provide STM-1, STM-4 interface IMAB: supply the IMA function DTB: realize E1 interface SDTB: realize channelized STM-1 interface GIPI: realize GE interface GUIM: switch data among the boards in the subrack. EIPI:interface board of RNC. It belongs to the access unit, providing the IP access based on E1 (working with DTB and SDTB).
Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
ZXWR RNC 2 Racks Capacity Subscribers Traffic Vol. BHCA Switch Capacity 1 Million 52,500Erl 7,000k 80Gbps ZXWR RNC rack1 L 1 L 2 L 3 L 4
Resourc e shelf Control shelf
Modularity design, ATM/IP gateway function, transmission and bandwidth convergency. RAU can expand independently to provide access interface, easy for future evolution to IP UTRAN.
Iu Throughput
Iub Throughput Max. Node B Max. Cell
6,100 Mbps
6,600 Mbps 1,900 5,700
rack2
Resource shelf
Control shelf
Switch shelf
High integration, large capacity, full configuration of one million subscribers needs only two racks. All-IP configuration, various interfaces Support ATM/IP dual protocol stacks, provides ATM UTRAN and IP UTRAN network configuration
as IP over E1, ATM over E1/STM-1, IMA E1/channelized STM-1, POS, FE, GE etc.
Iur/Iu/Iub
E1 (LINK)
GIPI UIM
ROMB
Iur/Iu/Iub
DTB CHUB
ICM
Iub
CSTM1/E1 (SDH/LINK)
RCB
PSN APBE
RUB
ZXWR RNC has the interface boards such as APBE,GIPI,IMAB,SDTB&DTB etc. ZXWR RNC supplies the rich interface type including E1,IMA E1,STM-1,CSTM-1,POS,FE,GE to realize the IP UTRAUN configuration.
CP Processing
Broadband Signaling
UP Processing
UP Processing
GTPU Processing
Interface Processing
IP
IP
IP
Different data is processed by different modules, enhanced hardware compatibility, each module can be upgraded and develop independently. Easy capacity expansion: modules stack.
rack1
rack2
L 4
L Resour 4 ce shelf
Resour L Resour L ce 1 shelf 1 ce shelf L Control L Control 2 shelf 2 shelf L control L 3 shelf 3 Resour L Switch L ce 4 shelf 4 shelf
Excellent RRM
Advantage of RRM
More than 60 related RRM patents Rich experience in CDMA
High reliability
Design Reliability
Switch plane adopt doubleplane User Plane adopt resource pool
MTBF<1h/20
years
Easy to O&M
Easy to O&M
Software upgrade online Friendly Machine interface Remote O&M Flexible report form customized On-line board testing
Switch shelf
Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
G U I M
IMAB GIPI
Interface Shelf
GLI
U I M C
CHUB
GLI
P S N
UIMC
Switch Shelf
G U I M
1) SBCX
Main Resource Shelf
2)
CHUB, ROMB, CLKG only in main control shelf SBCX only in main resource shelf
CHUB, ROMB and CLKG each config 1 pair for one RNC office (1+1backup) in the main control shelf. Other control shelves only have UIMC and RCB boards.
Name
ROMB RCB
Full Name
RNC Operating & Maintenance Board RNC Control plane processing Board
Configuration Principle
Each RNC 1 pair Depends on BHCA of the control plane traffic model
Backup Principle
1+1 1+1
CHUB
CLKG UIMC
1+1
1+1 1+1
Each RNC office has 2 GIPI (1+1) for OMCB in slot 11/12 of main resource shelf. Each RNC office has only 1 SBCX board in slot 1/2 of main resource shelf.
Name
RUB GIPI
Full Name
RNC User plane processing Board Gigabit IP Interface
Configuration Principle
Depends on user plan traffic model Provides 1 GE or 4 FE interfaces
Backup Principle
N+1 Load sharing or 1+1
APBE
SBCX
Load sharing
no
2
(S) D T B R D T B
3
I M A B
5
(S) D T B R D T B
6
(S) D T B R D T B
7
I M A B
9
G U I M R G U M 1
10
G U I M R G U M 2
11
(S) D T B R D T B
12
(S) D T B R D T B
13
I M A B
14
15
I M A B
16
17
(S) D T B R D T B
Name
DTB SDTB APBE IMAB EIPI
Full Name
Digital Trunk Board Sonet Digital Trunk Board ATM Process Board Enhanced IMA Board E1 IP Interface
Configuration Principle
Provides 32 E1 Provides 1 CSTM-1 Provides 4 ATM STM-1 Processing 64 IMA E1, 1IMAB+2DTB, 1IMAB+1SDTB Processing 64 IPoE1, 1EIPI+2DTB, 1EIPI+1SDTB
Backup Principle
Load sharing Load sharing or 1+1 Load sharing Load sharing Load sharing
Each GUIM has 2 GE, and each GLI has 4 GE, so 1 GLI can connect two resource shelf or interface shelf. (1acitve GLI 2 active GUIM 1 standby GLI 2 standby GUIM)
Name
PSN GLI UIMC
Full Name
Packet Switching Network
Configuration Principle
1 pair in switch shelf Each pair of GUIM(2 GE) corresponding to 1 GLI (4 GE) 1 pair in switch shelf
Backup Principle
1+1 1+1 1+1
Secondary
Optional
Alarming system
SDTB backup
Primary parameter: Parameter that must be provided by customer and filled. Secondary parameter: Necessary for some project and not necessary for others. Optional parameter: Maybe changed according to customers requirement
Application Scenario
Telecom exhibition, test project, trial project. Iub support all E1, all FE and hybrid access. No board redundancy. SBCX is configured as log server.
30 / 90
30/4
1000
4.68
Content
External Interfaces of RNC ZXWR RNC Functional Units ZXWR RNC Subracks ZXWR RNC Features ZXWR RNC Configuration ZXWR RNC Cable Connection
External power cable connects the cabinet-top filter with the external DC distribution cabinet.
S.N. 23 24
Connection
Cable - 48 V Power Cable - 48 V Power Cable Qty. End A 2 2 Blue: Filter 48 V input Black: Filter 48 VGND input End A Blue: Local 48 V power distribution box output Black: Local 48 VGND DC power distribution box output
To facilitate the connection of the power cable and the ground-ing cable, each ZXWR RNC rack is designed to bear one 48 V cable in-lead box on the top of the rack. Users neednt install cable of the power distribution box. Its pre-installed before delivery.
Connection
The power cable of cabinet-top fan shelf conducts 48 V that the busbar outputs to the fan monitoring board.
The service plug-in box leads in -48 V with the 6-core power socket. The cable falls into two parts: External line and internal line. The external line connects from the busbar to the plug-in box filter, while the internal line connects from plug-in box power filter to the backplane.
Grounding description
Grounding cable includes the grounding copper cable of the shelf, the grounding cable of the cabinet door, and the protection ground tandem cable inside the cabinet.
S.N. Cable 4 Grounding copper cable of the shelf Grounding cable of cabinet door Protection ground tandem cable inside the cabinet
Qty. 4 2 1
End A Plug-in box PE port Cabinet grounding cable port Cabinet-top protection ground
End A Grounding copper busbar Cabinet door Safety ground of the equipment room
Application Scenario
The intra-cabinet line falls into the internal cable and internal fiber. Usually, internal lines are ready before delivery.
Cable Classification
Clock Cable Interconnection Cable on Control Plane Interconnection Fiber on User Plane PD485 Cable and Fan Monitoring Cable
Application Scenario Monitoring System Cable Monitoring system cable include: Fan plug-in box monitoring cable, environment monitoring transfer cable, door control monitoring cable, infrared monitoring cable, temperature/humidity monitoring cable, and smoke monitoring cable. Ethernet Cable Ethernet cable implements the external Ethernet connection to Node B operation and maintenance center and ZXWR RNC operation and maintenance center. External Fiber External fiber is used to connect CN and Node B. E1/T1 Cable E1/T1 cable is used to implement the external connection from the ZXWR RNC to the CN.
Application Scenario
Exercise
Please write down the main function units of RNC. and write down the boards of each function units. RNC subrack include ( )( )( ) and ( ). 1 GIPI board can provide ( ) stm-1 interfaces, 1 DTB board provide ( ) E1 interfaces, 1 SDTB board provide ( ) CSTM-1 interface.