Hewlett Packard 3581A 15 Hz to 50 kHz Spectrum Analyzer Specifications

FREQUENCY CHARACTERISTICS Range Display Resolution Accuracy Typical Stability Automatic frequency control (AFC) hold-in range 15 Hz to 50 kHz 5 digit LED readout 1 Hz 3 Hz., 0 to 55C 10 Hz/hour after 1 hour and 5 Hz/C 800 Hz

AMPLITUDE CHARACTERISTICS Instrument Range Linear Log Frequency response, 15 Hz 50 kHz Dynamic range Noise Sidebands Spurious responses SWEEP CHARACTERISTICS Scan Width Sweep Error Light External Trigger INPUT CHARACTERISTICS Impedance Maximum Input Level 1 M, 30 pF 100 V rms, 100 V dc 50 Hz to 50 kHz, adjustable in a 1-2-5 sequence from 50 Hz to the full frequency range This LED indicates a sweep that is too fast to capture full response. When the light is on, response will be lower than it should be. A short to ground stops the normal sweep. Opening the short then enables a sweep. 30 V to 100 nV full scale +30 dBm or dBV to -150 dBm or dBV Amplitude Accuracy Log: 0.4 dB Linear: 4% > 80 dB greater than 70 dB below CW signal. 10 bandwidths away from signal. > 80 dB below input reference level

OUTPUT CHARACTERISTICS Tracking generator output (also known as BFO or tracking oscillator output) Range 0 tp >1 V rms into 600

Frequency Response Vertical Horizontal Impedance Recommended Accessory Pen Lift Restored Output GENERAL Power Requirements Size Weight

3% 15 Hz to 50 kHz X-Y Recorder Analog Outputs 0 to +5 V 2.5% 0 to +5 V 2.5% 1 k HP 7090A Measurement Plotting System contact closure to ground during sweep acts as a narrow band amplifier 100V, 120V, 220V, or 240V +5% -10%, 48 Hz to 440 Hz, 10 VA typical 203.2 mm H X 285.8 mm W X 412.8 mm D (8" X 11 1/4" X 16 1/4") 11.5 kg (23 lb). Opt 001: 13.5 kg (30 lb)

You might also like