Professional Documents
Culture Documents
Ratings
Ratings
Ratings
_____________________
Operating Temperature Range
-40C to 70C -40C to 70C -40C to 70C -40C to 70C
Electrical Characteristics
Specifications are rated at Vin=12VDC at T=25C Sym Parameter Min Vin Iin Vout Isink Ro Ga Voltage Input Supply Current Alarm Outputs Alarm Output Voltage Output Sink Current Output Pull up Resistor Accuracy Hydrogen (H2) Methane (CH4) Propane (C3H8) Range Hydrogen (H2) Methane (CH4) Propane (C3H8) Tr Response Time* Hydrogen (H2) Methane (CH4) Propane (C3H8) * Response time decreases as gas concentration increases Alarm Delay Time Alarm Heart Beat Low Time Alarm Heart Beat High Time Reset Low Time 8,000 20,000 7,000 1 20 20 0 0 1 15 10 60 PPM PPM PPM Min Sec Sec Min Sec Sec mS @ 12.5% LEL 5,000 ppm @ 25% LEL 12,500 ppm @ 25% LEL 5,250 ppm Specified by Customer Optional Sensor OK pulse on Vout 9.5 4.8 .9 Typ 12 80 5 1 +/- 500 +/- 1,250 +/- 525 Max 24 110 3 5.2 50 1.1 Units V mA V mA Kohm PPM PPM PPM Optional pull up resistor required Open collector options Logic option 5V @ 12.5% LEL 5,000 ppm @ 25% LEL 12,500 ppm @ 25% LEL 5,250 ppm Conditions
Gr
5VDC
Description Voltage input (9.5 24 VDC) Sensor ground Open collector alarm output 1 (Standard) Open collector alarm output 2 (Optional) / RS232 Rx Open collector alarm output 3 (Optional) / RS232 Tx Alarm Reset Input (pull to ground)
1K
Output Diagram
1 Vin 2 GND 3 Alarm 1 (Vout) 4* Alarm 2 (Vout)(Rx) 5* Alarm 3 (Vout)(Tx) 6 Reset * Optional outputs