S & B ENGINEERS and CONSTRUCTORS, LTD.

REV: M2+
PAGE:
INFO ISSUE DATE:
PRINT DATE:
S & B JOB NO.:
SASOL JOB NO.:

LINE LIST
BY FLOW DIAGRAM AND LINE NUMBER
Lake Charles, LA
S & B ENGINEERS and CONSTRUCTORS, LTD.
LINE NUMBER
SIZE-SVC-UNIT-NBR-INSUL-SPEC
MATERIAL-MAINT.TEMP-AREA-ISO

ECHO-1 PROJECT
FLOW DIAGRAM LCCC-012-PI-101-D

HOUSTON, TX.

LINE LOCATION
ORIGIN
TERMINATION

FLOW
DIAGRAM

FLUID

OPERATING
NORM. MAX.
PRESS PRESS
TEMP. TEMP.

EMERGENCY
PRESS
TEMP.

F DESIGN
STRESS
R
TEST INSL PAINT ANALYS WALL
E SPCL. PRESS PRESS TYPE SPEC REQD. THICK
Q RQMT. TEMP. FLUID THIK

1 1/2"-HM-012.1-001-E-A2-1
KILLED CS
86
100
6"-HM-012.1-002-E-B2-1
CS
86
100

6"-HM-012.1-002-E-B2-1
012-PI-101-D
D12-102
D12-101
012-PI-101-D
1.5"-HM-012.1-001-E-A2-1

HYDROCARBON 55
104
HYDROCARBON 55
104

66
125
66
554

100
158
145
662

B SO

3"-HM-012.1-003-E-B2-1
CS
86
100

6"-HM-012.1-002-E-B2-1
PSV-V12-1001

012-PI-101-D

HYDROCARBON 23
110

150
550

150
662

4"-FW-012.1-004-N-A2-1
CS
100

PSV-V12-1001
20"-FW-012.9-152-N-A2-1

012-PI-101-D
012-PI-943-D

VENT

8
554

6"-HM-012.1-005-P-B2-1
CS
100

6"-HM-012.1-006-E-B2-1
10"-HM-012.7-035-P-B2-1

012-PI-101-D
012-PI-716-D

HYDROCARBON 20
550

6"-HM-012.1-006-E-B2-1
CS
86
100

1.5"-HM-012.9-025-N-A2-1 012-PI-101-D
D12-101

HYDROCARBON 60
104

1
80

450
H2O
1125
H2O

B SO

180
662

1125 E
IX
H2O 1.5"

YES-I STD

INSUL MTL=MINERAL WOOL


PM-203
Regeneration
Temperature
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

10
662

38
662

450
H2O

YES-I STD

PM-203,101
NO UNIONS & TFE BOLTS
NO RTFE BUTRFLY VLV & BALL
VLVS (NPS 1/2-2)
NO RTFE BALL VLV NPS 3-6
NO RTFE BALL VLV NPS 8 & UP
NO HIGH TEMP PLUG VALVES

24
554

203
662

B SO

203
662

1125 P
*RMKS YES-I STD
H2O 2.5"
503

INSUL MTL=MINERAL WOOL


PM-203,101
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE
*Paint:IX-insl, IV-uninsl

72
554

145
662

B SO

145
662

1125 E
H2O 2"

INSUL MTL=MINERAL WOOL


PM-203
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

*** NOTE: SHADED AREAS INDICATE DATA HAS BEEN CHANGED SINCE REVISION 'M2' WAS FORMALLY ISSUED.

N
IV
NONE

IX

NONE

XS

REMARKS

100
175
145
662

B SO

E
VII
1.5"
E
IX
2"

5
09/28/11
11/03/11
C1445
06A00211

YES-I STD
501

YES-I STD
503

INSUL MTL=MINERAL WOOL


PM-203
INSUL MTL=MINERAL WOOL
PM-203
SP-114
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

S & B ENGINEERS and CONSTRUCTORS, LTD.

REV: M2+
PAGE:
INFO ISSUE DATE:
PRINT DATE:
S & B JOB NO.:
SASOL JOB NO.:

LINE LIST
BY FLOW DIAGRAM AND LINE NUMBER
Lake Charles, LA
S & B ENGINEERS and CONSTRUCTORS, LTD.
LINE NUMBER
SIZE-SVC-UNIT-NBR-INSUL-SPEC
MATERIAL-MAINT.TEMP-AREA-ISO

ECHO-1 PROJECT
FLOW DIAGRAM LCCC-012-PI-101-D

HOUSTON, TX.

LINE LOCATION
ORIGIN
TERMINATION

FLOW
DIAGRAM

FLUID

OPERATING
NORM. MAX.
PRESS PRESS
TEMP. TEMP.

EMERGENCY
PRESS
TEMP.

F DESIGN
STRESS
R
TEST INSL PAINT ANALYS WALL
E SPCL. PRESS PRESS TYPE SPEC REQD. THICK
Q RQMT. TEMP. FLUID THIK

3"-HM-012.1-012-E-A2-1
012-PI-101-D
1.5"-HM-012.9-030-E-A2-1 012-PI-903-D

HYDROCARBON 43
104

52
125

100
158

B SO

100
175

450
H2O

3"-HM-012.1-009-E-B2-1
CS
86
100

6"-HM-012.1-006-E-B2-1
2"-HM-012.1-283-N-A2-1

012-PI-101-D

HYDROCARBON 20
104

43
125

145
150

B SO

145
175

1125 E
VII
H2O 1.5"

YES-I STD
503

3"-HM-012.1-012-E-A2-1
CS
86
100

D12-102
D12-110

012-PI-101-D
012-PI-111-D

HYDROCARBON 54
104

65
125

100
158

B SO

100
175

450
H2O

NONE

STD

INSUL MTL=MINERAL WOOL


IP-101
PM-203,209
SP-101

2"-HM-012.1-047-H-B2-1
KILLED CS
100

D12-101 TRIM

012-PI-101-D

HYDROCARBON 26
536

31
662

145
662

B SO

145
712

1125 H
H2O 2"

NONE

XS

INSUL MTL=MINERAL WOOL


PM-203
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

1 1/2"-HM-012.1-049-E-A2-1
KILLED CS
86
100
2"-HM-012.1-283-N-A2-1
KILLED CS
100

D12-102 TRIM

012-PI-101-D

100
158
145
104

100
158
145
154

450
H2O
450
H2O

NONE

XS

012-PI-101-D
012-PI-312-D

65
103
43
104

B SO

3"-HM-012.1-009-E-B2-1
D12-310

HYDROCARBON 55
86
HYDROCARBON 20
104

NONE

XS

INSUL MTL=MINERAL WOOL


PM-203
PM-203,207
DESIGN FOR FUTURE
INSULATION AND ELECTRIC
TRACING

3"-HM-012.1-288-E-B2-1
CS
86
100

3"-HM-012.1-003-E-B2-1
4"-FW-012.1-004-N-A2-1

012-PI-101-D

HYDROCARBON 23
110

30
550

145
662

B SO

145
662

1125 E
IX
H2O 1.5"

YES-I STD

INSUL MTL=MINERAL WOOL


PM-203
SP-102
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

1"-IN-012.1-289-H-B2-1
KILLED CS
100

1"-IN-012.1-310-N-A2-1
6"-HM-012.7-061-H-B2-1

012-PI-101-D

GAS

23
110

30
554

203
662

203
662

1125 H
H2O 1"

YES-I XS
501

INSUL MTL=MINERAL WOOL


PM-203
NO UNIONS & TFE BOLTS
NO BUTTERFLY VALVES
NO PTFE PLUG VALVE
NO HIGH TEMP PLUG VALVE

1"-IN-012.1-310-N-A2-1
KILLED CS
100

1"-IN-012.8-297-N-A2-15
1"-IN-012.1-289-H-B2-1

012-PI-101-D

GAS

115
77

120
92

129
149

150
149

450
H2O

NONE

PM-203

*** NOTE: SHADED AREAS INDICATE DATA HAS BEEN CHANGED SINCE REVISION 'M2' WAS FORMALLY ISSUED.

E
VII
1.5"

IX

E
VII
1.5"
N
III
NONE

IX

N
III
NONE

NONE

XS

REMARKS

1 1/2"-HM-012.1-007-N-A2-1
KILLED CS
100

B SO

N
III
NONE

6
09/28/11
11/03/11
C1445
06A00211

XS

PM-203,304,101,301
DESIGN FOR FUTURE
INSULATION AND ELECTRIC
TRACING
INSUL MTL=MINERAL WOOL
PM-203
SP-102