Current Transformers: LRGBJ Series: 40.5 550kV
Current Transformers: LRGBJ Series: 40.5 550kV
Current Transformers: LRGBJ Series: 40.5 550kV
5~550kV
Current Transformers
Safe, Reliable High-Voltage Current Transformers That Never Need Maintenance
Current transformers are used in electrical grids for measurement and protective applications to provide signals to equipment such as meters and protective relays by stepping down the current of that system to measurable values. Their role in electrical systems is of primary importance because the data sent by current transformers represent the heartbeat of the entire system. RHM Internationals proprietary dry type Current Transformers are unique as they provide a rugged, reliable option for high voltage metering and protection operations up to 550 kV. Our high quality Current Transformers are based on a unique U-shaped bushing design for the primary winding. The bushing is a very fine capacitance graded insulator. In a new approach to dry designs, our advanced proprietary HV DryShieldTM composite insulation system uses reliable materials like PTFE (Polytetrafluoroethylene) and silicon rubber to provide a low stress, uniform field distribution between the conductor and the outside structure. The primary and secondary windings are independently sealed resulting in a totally weather resistant design. Oil or gas is not required for insulation. Therefore, our environmentally friendly Current Transformers completely eliminate the risk of explosion and toxic leaks. Considering the difficulty for our customers to schedule circuit outages for routine upgrades and maintenance, the high cost of maintenance, and environmental issues, RHM Internationals Current Transformers provide exceptionally low cost of ownership and offer you peace of mind as they are truly maintenance free. Customer benefits:
Dielectric Dissipation Factor (Tan) Flashover Risk Manufacture Time
LRGBJZHD 110 kV
LRGBJ110 kV
Totally safe no risk of explosion Totally maintenance free exceptional low cost of ownership Environmentally friendly no risk of toxic leak and recyclable insulation materials 2 to 3 times lighter than conventional oil or gas based products Mature and Innovative with unmatched quality records not a single failure in 20 000 HV DryShieldTM equipped products in the field A new approach to dry design without the limitations of conventional dry Current Transformers All products are developed and manufactured in an ISO 9001 certified plant and compliant to IEC and IEEE international standards.
Partial Discharge
Maintenance Required
Component Weight
A TR Electric Partner
RHM International LLC 81 Glen Road, Brookline, MA 02445 USA Tel/Fax: +1 617 608 0274 info@rhmintl.com www.rhmintl.com
Main Characteristics 1.Performance Highest voltage for equipment: 40.5-550 kV Rated primary current: Rated secondary current: Rated output: Rated frequency: 50, 60 Hz 5-5000 A (up to 8000 A under specific conditions please contact us) 5 A, 1 A 10-50 VA 0.2S, 0.2, 0.5S and 0.5 class
Accuracy limit factor for protective current transformer: 5,10, 15, 20, 30, 40 Secondary cores: 1-8
All products comply with IEC-44-1-1996 Current Transformers and IEEE C57.13 standards Protective class current transformers comply with IEC-44-6: 1992 Requirements for Protective Current Transformers for Transient Performance 2. Environmental Condition Places of operation: Environmental temperature: Altitude: Pollution level: Indoors and outdoors -45 [-49F] / +45 [113F] c c <1000m above sea level (when higher than 1000m, specific design available. Please contact us) fully compliant to Class IV environments (IEC category very heavy pollution level)
3. Type tests and special tests include: Measurement of capacitance and Dielectric Dissipation under Um/3 and 10kV, the Dielectric dissipation factor (tan) is less than 0.004 Short-time current tests: Thermal short-time current (Ith): Rated dynamic current (Idyn): Temperature-rise test: Mechanical tests (see table 2) Determination of errors 50 kA, 3s 125 kA (peak value) 75 K 40.5 72.5 126 252 550
Highest voltage for equipment Um kV (r.m.s.) Rated power Rated frequency switching withstand impulse voltage withstand 1 min50/60 Hz. voltage kV kV (r.m.s.) (peak) Rated lightning impulse withstand voltage kV (peak) Rated chopped lightening impulse withstand voltage kV Partial discharge pC
1175*
Insulation and thermal stability test (36h according to standard but tested 72h for 550kV)
4. Routine tests: Before leaving the factory the following routine tests are carried out: on primary winding: Power-frequency withstand test Power-frequency withstand test between sections of primary Partial discharge measurement Capacitance and dielectric dissipation factor measurement Verification of terminal markings 5.Maintenance: Maintenance is not needed on secondary windings: Power-frequency withstand test Power-frequency withstand test between sections of secondary windings Inter-turn over-voltage test Determination of errors Highest voltage Um (kV) 5.72.5 126 252 550 Table 2 Static forces (N) 1250 2000 4000 4000
Maintenance-free
Dimensions (mm)
L4 400 400 400 400 400 580 580 580 580 580 580 580 580 860 860 860 860 860 L5 360 360 360 360 360 200 200 200 200 200 200 200 200 350 350 350 350 350 L6 350 350 350 350 551 551 551 551 551 551 551 551 551 715 715 715 715 715 1260 L7 320 320 320 320 320 400 400 400 400 400 400 400 400 500 500 500 500 500 700 a b 15 14 15 14 15 14 15 14 15 18 15 14 15 14 15 14 15 14 15 14 15 14 15 14 19 18 19 14 19 14 19 14 19 14 19 18 see figure t 12 12 14 14 14 12 12 14 12 12 14 14 14 12 12 14 14 14
Weight (kg/lb)
90/198 90/198 90/198 90/198 90/198 200/441 200/441 200/441 240/529 240/529 240/529 240/529 240/529 440/970 440/970 440/970 440/970 440/970 3000/6614
All dimensions are indicative of typical designs - actual dimensions are confirmed with orders. Special sizes available upon request.
LRGBJ CT
A L7
20 40
L +/- 30
40 125
22.5
6-14
525
L4 L1 L2 L3 +/- 0.5 t
L3 +/- 0.5
L6 +/- 10
L5 4-a
590015
L1
4-b
1260
d20
4-50
High Current CT
Model & Specification
LRGBJ - ZHD - 72.5 / 4000 LRGBJ - ZHD - 72.5 / 6000 LRGBJ - ZHD - 126 / 4000 LRGBJ - ZHD - 126 / 6000 LRGBJ - ZHD - 252 / 4000 LRGBJ - ZHD - 252 / 6000
Dimensions (mm)
L4 30 32.5 30 32.5 30 32.5 L5 580 580 580 580 860 860 L6 200 200 200 200 350 350 L7 531 531 531 531 715 715 L8 400 400 400 400 500 500 a 15 15 15 15 19 19 D 18 18 18 18 18 18
Weight (kg/lb)
All dimensions are indicative of typical designs - actual dimensions are confirmed with orders. Special sizes available upon request.
When placing an order, customers specification needs to include: Highest voltage Um Rated current Rated frequency Rated transformation ratio Number of secondary windings Rated output (20~50VA) Accuracy class: 0.2s, 0.2, 0.5s, 0.5or 5P, 10P, TPY Accuracy limit factor (5\10\15\20\25\30) Instrument security factor: 5,10 If users have specific requirements, custom designs can be jointly defined.
RHM International LLC 81 Glen Road Brookline, MA 02445 USA Tel/Fax: +1 617 608 0274 info@rhmintl.com www.rhmintl.com
A TR Electric Partner