CONFIGURATION AND TERMINAL OUTPUTS INSTALLER/CONFIGURATION MENU

80 SERIES BLUE 1F80-0471/1F86-0471

Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change a menu item.

INSTALLER/CONFIGURATION MENU
MENU REF. HP PRESS DISPLAYED SS BUTTON (FACTORY DEFAULT) Press or to select from listed options COMMENTS

1 2 3 4 5 6 7 8 9

1 2 3 4 1 2 3 4 5 5 6 7 6 7

MENU MENU

On (Cool O) P (2)

Heat b On P 3, P 0 Cool Saving CS On 6, 5, 4, 2, 1 E OFF FA, SL SL SL CL On Heat Cool Off, Heat Off with Fan icon, Heat Off without Fan icon, Cool Off, Auto Off Heat Off with Fan icon, Heat Off without Fan icon, Cool Off L OFF 1 HI, 2 HI, 3HI, 4 HI, 1 LO, 2 LO, 3 LO, 4 LO C Change Filter On 25 h to 1975 h in 25-hour increment

Reversing Valve Output (Heat Pump switch must be in the Heat Pump HP position) Selectable Programs Per Week (For programmable thermostat only) Select Cool Savings on or off Selects Cool Savings value 1 (low) to 6 (high) Selects Energy Management Recovery (EMR) on or off Adjustable Anticipation (Heat) (only when heat pump switch is at the SS position) Adjustable Anticipation (Cool) (only when heat pump switch is at the SS position) Adjustable Anticipation (Heat Pump) (only when heat pump switch is at the HP position) Compressor Lockout Time System Mode Configuration with Automatic Changeover

MENU Cool Saving CS (OFF) CS (3) MENU MENU MENU MENU MENU MENU E (On) CR Heat (ME) CR Cool (FA) CR Heat Pump (FA) CL (OFF) Auto Heat Cool Off

Cool Off Heat

System Mode Configuration without Automatic Changeover Selects Display Light on or off Adjustable Ambient Temperature Display Selects Fahrenheit/Celcius Temperature Display Selects Filter Change-out Indicator When on, selects time in 25 hour increments Returns to Normal Operation

10 11 12 13

8 9 10 11

8 9 10 11

MENU MENU MENU MENU

L (On) 0 HI F Change Filter (OFF) Change Filter 200 h

14

12

12

RUN

Single Stage (Gas, Oil, Electric)


RH
TECHNICAL HELP

RC 24 V for Cool

W Heat Relay

G Fan Relay

Y Compressor Relay

O/B 3-wire zone valve

C 24 V Common

24 V for Heat

Single Stage Heat Pump (No Auxiliary Heat)


RH 24 V for Heat RC 24 V for Cool W Heat Relay (with jumper to Y) G Fan Relay Y Compressor Relay (with jumper to W) O/B C Changeover 24 V Relay O for Common Cool, B for Heat

SS HP

GAS ELEC

Single Stage/Heat Pump Selection Switch 84


www.white-rodgers.com

Gas/Electric Switch