Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change a menu item.
INSTALLER/CONFIGURATION MENU
MENU REF. HP PRESS DISPLAYED SS BUTTON (FACTORY DEFAULT) Press or to select from listed options COMMENTS
1 2 3 4 5 6 7 8 9
1 2 3 4 1 2 3 4 5 5 6 7 6 7
MENU MENU
On (Cool O) P (2)
Heat b On P 3, P 0 Cool Saving CS On 6, 5, 4, 2, 1 E OFF FA, SL SL SL CL On Heat Cool Off, Heat Off with Fan icon, Heat Off without Fan icon, Cool Off, Auto Off Heat Off with Fan icon, Heat Off without Fan icon, Cool Off L OFF 1 HI, 2 HI, 3HI, 4 HI, 1 LO, 2 LO, 3 LO, 4 LO C Change Filter On 25 h to 1975 h in 25-hour increment
Reversing Valve Output (Heat Pump switch must be in the Heat Pump HP position) Selectable Programs Per Week (For programmable thermostat only) Select Cool Savings on or off Selects Cool Savings value 1 (low) to 6 (high) Selects Energy Management Recovery (EMR) on or off Adjustable Anticipation (Heat) (only when heat pump switch is at the SS position) Adjustable Anticipation (Cool) (only when heat pump switch is at the SS position) Adjustable Anticipation (Heat Pump) (only when heat pump switch is at the HP position) Compressor Lockout Time System Mode Configuration with Automatic Changeover
MENU Cool Saving CS (OFF) CS (3) MENU MENU MENU MENU MENU MENU E (On) CR Heat (ME) CR Cool (FA) CR Heat Pump (FA) CL (OFF) Auto Heat Cool Off
System Mode Configuration without Automatic Changeover Selects Display Light on or off Adjustable Ambient Temperature Display Selects Fahrenheit/Celcius Temperature Display Selects Filter Change-out Indicator When on, selects time in 25 hour increments Returns to Normal Operation
10 11 12 13
8 9 10 11
8 9 10 11
14
12
12
RUN
RC 24 V for Cool
W Heat Relay
G Fan Relay
Y Compressor Relay
C 24 V Common
24 V for Heat
SS HP
GAS ELEC
Gas/Electric Switch