Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

STDesign 3.

1 Decon Studrail Design Copy of Connection 1, Page 1


lok_punching shear PROJECT DATA Project name: Untitled Project Project number: lok Engineer: anb Date: 27 December 2011 File path: INPUT DATA Connection name: Copy of Connection 1 General: Design code: ACI 318-05 System of units: SI (mm, kN, kN-m, MPa) Connection: Connection location: Interior Column dimension, dc: 600.0 mm Loads: Vu: 200.0 kN Mux: 0.000 kN-m Muy: 0.000 kN-m Slab: Effective depth, d: 150.0 mm Slab thickness: 200.0 mm Top cover: 25.00 mm Bottom cover: 25.00 mm Concrete compressive strength, f'c: 30.00 MPa Concrete density: Normal weight Prestress, fpc: 1360 MPa Studrails: 2003/2006 IBC ductility requirement: No Stud yield strength, fyv: 344.7 MPa Stud diameter: 12.7 mm Typical stud spacing, S: Automatic End stud spacing, S0: Automatic Number of studrails: Automatic

Openings: None.

STDesign 3.1 Decon Studrail Design Copy of Connection 1, Page 2


STUDRAIL SUMMARY Number of studrails per column: N/A Number of studs per studrail: N/A Stud diameter: N/A OUTPUT DATA Inner Critical Section (d/2 outside of column face): Common Properties Area, Ac: 3.529105 mm2 Natural Axis Properties Centroid coordinate, ex: 0.0 mm Centroid coordinate, ey: 0.0 mm Section moment of inertia, Ix: 2.4651010 mm4 Section moment of inertia, Iy: 2.4651010 mm4 Section product of inertia, Ixy: 0.0 mm4 Typical stud spacing, S: N/A End stud spacing, S0: N/A Overall height of studrail: N/A

Natural Axis Loads Vu: 200.0 kN Mux: 0.0 kN-m Muy: 0.0 kN-m Stresses Maximum shear stress, vu: 0.5668 MPa at x = 375.0 mm, y = 0.0 mm

Critical Section Perimeter, b0: 2352 mm Principal Axis Properties Centroid coordinate, e1: 0.0 mm Centroid coordinate, e2: 0.0 mm Section moment of inertia, I1: 2.4651010 mm4 Section moment of inertia, I2: 2.4651010 mm4 Principal axis rotation, (theta): 0.0 degrees Moment fraction, v1: 0.400 Moment fraction, v2: 0.400 Principal Axis Loads Vu: 200.0 kN Mu1: 0.0 kN-m Mu2: 0.0 kN-m Shear resistance, vn (concrete only): 1.970 MPa Shear resistance, vn (upper limit): 2.047 MPa

Outer Critical Section (d/2 outside of reinforced zone): N/A Design Comments: Studrails are not required. The maximum factored shear stress, vu, is only 0.5668 MPa, but the resistance without Studrails, vc, is 1.970 MPa.

STDesign 3.1 Decon Studrail Design Copy of Connection 1, Page 3


PLAN VIEW

ELEVATION VIEW