Professional Documents
Culture Documents
3900 Bts Structure
3900 Bts Structure
3900 Bts Structure
Upon completion of this course, you will be able to: > Know the functions and features of BTS3036 > Master the BTS3036 hardware structure > Master the cable connection of BTS3036
Page 2
References
BTS3036 Product description BTS3036 Installation Manual BTS3036 Hardware description
Page 3
Page 4
BTS3036 to minimize the number of spare parts and reduce the cost.
It can be flexibly installed in a small footprint and can be easily
maintained
It supports multiple frequency bands, such as PGSM900, EGSM900,
and DCS1800
Page 5
configuration of S4/4/4.
Page 6
Chapter 1 Overview Chapter 2 System Components Chapter 3 Signal Processing Chapter 4 Typical configuration
Page 7
Page 8
Configuration Type Empty cabinet Full Configuration Configuration Type Cabinet Width (mm) 600
Page 9
(2) Fan box (4) Direct current distribution unit (6) Cable in/out unit -
Page 10
Page 11
Page 12
Common Subsystem
(1) BBU Control subsystem whose functions are implemented by the BBU (2) DRFU RF subsystem whose functions are implemented by the DRFU (3) DCDU Power subsystem (4) Fan Box
Page 13
interaction
Provides the CPRI ports for communication with the DRFU Provides the USB port for downloading the BTS software Provides OM channels for connection to the LMT (or M2000) Processes UL and DL data Provides centralized management on the entire BTS system,
Page 14
Page 15
Page 16
Page 17
UELP board
OUTSIDE
Page 18
FE0
FE1
DLC connector
Page 19
MON1 EXTALM0
EXTALM1
RJ45 connector
Page 20
USB
A reserved port that performs the following function: Automatically upgrades the software through the USB disk. For testing of the output clock signals by using a tester
TST
Page 21
Page 22
GTMU to monitor and manage the service board, power, backplane, and fan.
High-speed signal management: The BSBC distributes and converges
information about data, control, and management of all boards in the baseband unit system
Service signal: The BSBC transfers the UL and DL baseband data of the
GTMU.
Page 23
Page 24
(1) Processes the two-channel 12 V power input by the backplane to provide power for the fan (2) Communicates with the GTMU to control and monitor the fan (3) Detects and adjusts the fan speed (4) Detects the board temperature by the built-in temperature sensor (5)Provides the automatic reset function
Fan: performs forced heat dissipation for the entire BBU
Page 25
Page 26
information associated with the boards and modules Structure and working principles of the UPEU
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Description Provides the input and output of optical and electrical transmission signals Local maintenance and commissioning A reserved port that performs the following function: Connects the BBU to a routing device in the equipment room through the Ethernet cable to transmit network information
Page 33
Page 34
Page 35
This link is not used or the alarm is cleared. The CPRI link is functional. The reception of the optical module is abnormal and an alarm is generated.
Page 36
Page 37
Description
channel, modulates the baseband signals to GSM RF signals. After filtering, amplifying, and combining the RF signals, the DRFU sends the signals to the antenna for transmission. The combining can be performed as required.
It receives RF signals from the antenna and performs down-conversion,
amplification, analog-to-digital conversion, matched filtering, and Automatic Gain Control (AGC). Then, the DRFU transmits the signals to the BBU for further processing.
It controls power and detects the Voltage Standing Wave Ration (VSWR).
Page 39
Page 40
Page 41
Page 42
Page 43
Status
Meaning No VSWR alarm is detected. The VSWR alarm is generated on only the ANT2 port. The VSWR alarms are generated on the ANT1 and ANT2 ports. The VSWR alarm is generated on only the ANT1 port. The CPRI link is functional. The interface module fails to receive signals. The CPRI link has a loss-of-lock error. The CPRI link is functional. The interface module fails to receive signals. The CPRI link has a loss-of-lock error.
All rights Reserved Page 44
the -48 V DC power to the BBU, DRFU, and fan box in the cabinet. DCDU (10 outputs)
Page 46
Page 47
SPARE2, SPARE1, BBU, Power ports supplying the 10 outputs of power FAN, and RFU5-RFU0 to the BBU, DRFU, GATM, and fan box SPARE2, SPARE1, BBU, Power switch controlling the 10 outputs for the FAN, and RFU5-RFU0 BBU, DRFU, GATM, and fan box SPD ALM Dry contact alarm output port
Page 48
Thank You
www.huawei.com