< '3' Stress 1 riaxiai Compression JLJnconfined Compression Test

Sample details Depth Description


Sketch showing specimen location in original sample

Type
Height, HD (mm) Diameter, DD (mm) Weight W0 (gr) Bulk Density p (Mg/m3)

Particle Density ps

3.50m Yellowish brown CLAY with sand & gravel Specimen 1

76 38 153.12
1.78

2.65

Initial Conditions

Cell Pressure <j3 (kPa) viachine Speed dr (mm/'min) No. of Membranes Total Thickness (mm) Strain Channel Load Channel Moisture Content wo % Dry Density pdo (Mg/m3) Voids Ratio e0 Deg of Saturation S0 % Specimen 1 0 1.52 0

0 31 1.35 0.96 86.46

Final Condition Specimen 1 Max Deviator Stress (kPa) Membrane Correction amv, (kPa) orr Stress (CT., - d3)c (kPa) Strain at Failure ef % Shear Strength GU (kPa) Moisture Content w. % Dry Density pdf (Mg/m3) Voids Ratio ef Deg of Saturation S; % I Notes: 67.22 0.00 67.22 5.00 33.61 31 1.35 0.96 86.46 Shear

iTest Method : BS 1377: Part 7: 1990 :7

:Sample:

UD1 borehole : BH 3

"Approved Dhararn Sinah


Project : BALAI BOMBA DAN KUARTERS, JALAN HANG :_______TUAH, WILAYAH PERSEKUTUAN_____ _

i Checked :Chris