Assignment 6.5.

4- Auxiliary System
Starting Diesel Generator procedures 1. Before starting generator, ensure diesel generator lubricating oil sump level, rocker arm lube oil sump level. 2. Diesel generator lube oil priming pump should run on Auto mode & diesel oil supply pump on auto. 3. Drain starting air line for water. 4. Change over diesel generator control switch to local mode 5. Put starting lever to stop position. 6. Open all indicator cocks and crank the generator to ensure no seizure. 7. Blow through diesel generator with air by pressing start button. 8. Shut all indicator cocks and put starting lever to start position. 9. Start the generator by pressing start button. 10. After generator is started, check all parameters are normal. 11. Back flush lube oil filters. (For auxiliary engine lube inlet & turbocharger inlet). 12. Change over diesel generator starting control to remote. 13. Generator is ready for running onloads. After running on load, change over generator to heavy fuel oil.