FreedomCAR 42 V Energy Storage System End-of-Life Performance Goals (August 2002) 42 Volt Targets Rev.

August 2002
Discharge Pulse Power (kW) Regenerative Pulse Power (kW) Engine-Off Accessory Load (kW) Available Energy (Wh @3 kW) Recharge Rate (kW) Energy Efficiency on Load Profile (%) Cycle Life, Miles/Profiles (Engine Starts) Cycle Life and Efficiency Load Profile Cold Cranking Power @ -30C (kW) Calendar Life (Yrs) Maximum System Weight (kg) Maximum System Volume (Liters) Selling Price ($/system @ 100k/yr) Maximum Open Circuit Voltage (Vdc) after 1 Sec. Minimum Operating Voltage (Vdc) Self Discharge (Wh/day) Heat Rejection Coefficient (W/C) Maximum Cell-to-Cell Temperature Difference (C) Operating Temperature Range (C) Survival Temperature Range (C) Start-Stop M-HEV P-HEV

6 2s 13 2 sec 18 10 sec N/A 8 2 sec 18 2s 3 5 min 3 5 min 3 5 min 250 300 700 2.4 kW 2.6 kW 4.5 kW 90 90 90 150k (450k) 150k (450k) 150k (450k) Zero Pwr Asst (ZPA) Partial Pwr Asst (PPA) Full Pwr Asst (FPA) 8 21 V Min. 8 21 V Min. 8 21 V Min. 15 15 15 10 25 35 9 20 28 150 260 360 48 48 48 27 27 27 <20 <20 <20 N/A N/A >30 N/A N/A <4 -30 to +52 -30 to +52 -30 to +52 -46 to +66 -46 to +66 -46 to +66