NOTES
1. THIS DRAWING TO BE READ IN CONJUNCTION WITH GENERAL STRUCTURAL NOTES DRAWING. 2. THE DETAILS SHOWN ON THIS DRAWING ARE BASED ON REQUIREMENTS OUTLINED IN A.S.1657 (S.A.A. CODE FOR FIXED PLATFORMS,WALKWAYS,STAIRWAYS AND LADDERS) AND ARE MINIMUM ACCEPTABLE. THE TYPE AND EXTENT OF HANDRAILS IS SHOWN ON THE DESIGN DRAWINGS. CONTACT SURFACES OF HANDRAILS SHALL BE SMOOTH AND FREE FROM BURRS AND SHARP CORNERS. ALL HANDRAILS ON THIS DRAWING ARE MONOWILLS HANDRAILING. ALL HANDRAIL STANCHIONS AND RAILING TO BE HOT DIPPED GALVANISED U.O.N.. TYPE P STANCHIONS ARE NOT RECOMMENDED WHERE CUT-OUTS IN THE FLOORING ARE REQUIRED FOR STANCHION INSTALLATION. IF BENT PIPE IS NOT CONTINUOUS THROUGH STANCHION BALL, USE SPLICE (DETAIL P) OR FULLY WELD PIPE TO STANCHION.
460
3. 4.
a
5.
1020
560
KICKPLATE (TYP)
505
485
KNEERAIL - 25 NB. (33.7 OD) x 3.2 GAUGE PIPE KICKPLATE - 100 x 6 FL WELDED OR D D BOLTED 1 - M12-4.6/S
6. 7.
ES RI VA
45
8.
ES RI
55
75
150
VA
75
90 BEND
PREFERRED ANGLE a = 37
SIDE - S
SIDE-OFFSET-SO
PLATFORM-P
WELDED-W
CORED-C
OFFSET CORED -C
ANGLE MOUNTED - AM
B INSIDE FACE
A
WELDED
TYPE AM STANCHION
TYPE P STANCHION A
0 14 R
00 20
NT CE X. MA
S RE
COMPLIMENTARY ANGLE TO STAIR ANGLE TYPE SO STANCHION TOP OR INTERMEDIATE RAIL B STANDARD 90 BEND:'A' & 'B' = 300 NON STD BEND : 'A' + 'B' = 6500 MAX. 'A' OR 'B' MINIMUM =200 STANCHION CENTRES REMAIN AT 2000 DESPITE BEND LENGTH. STANDARD ANGLE BEND: 'A' & 'B' = 300 NON STD. ANGLE BEND : 'A' +'B' = 6500 MAX. 'A' OR 'B' MINIMUM = 200 STANCHION CENTRES REMAIN AT 2000 DESPITE BEND LENGTH.
1-M16 8.8/S
100 x 6 FL
BOLTED
2000 100 x 6 KICKPLATE MAX. 700 NOMINAL W.P. 58 ANGLE CLOSURE BEND (ACB) ANGLE TO SUIT STAIR PREFERRED ANGLE a= 37 140 RAD. KICKPLATE SUPPORT
20 00 MA X.
2000 MAX.
100 MAX.
PROVIDE HORIZONTAL CLOSURE BEND WHERE COLUMNS DO NOT ALLOW CONTINUATION OF HANDRAIL
10 (MAX.)
ONE BALL C OB STANCHION (ONE BALL) WITH CHAIN HOOKS 300 300 TYPE C STANCHION 10 GAP GREATER THAN 1200: REMOVABLE STANCHIONS AT 2000 CTRS. MAX. KICKPLATE SUPPORT 100 x 6 KICKPLATE
0 R14
CE NT RE S
W.P.
VA W RI AN ITH ES GL E
TYPICAL REMOVABLE SAFETY CHAIN & RAIL/COLUMN CONNECTION DETAILS TYPICAL REMOVABLE PANEL
NOTE 8. OR DETAIL P
PREFERRED MIN.
MR 01/08/07 TW 19/5/05
BY DATE
280
2 OFF 90 BENDS
TYP
100
TYPICAL CLOSURE TYPICAL STAIR & PLATFORM HANDRAIL DETAILS HANDRAIL JOINT
FO
GEN R
E EAS EL LR ERA
0
REV
WEBFORGE (WA)
24 TENNANT STREET, WELSHPOOL WESTERN AUSTRALIA A.C.N. 009 419 756
Phone (08) 9361 8933 Fax (08) 9361 7057
STD - 101/0
REV.
TAW
DATE
11/94
JOB No.