Download as pdf or txt
Download as pdf or txt
You are on page 1of 35
es cCNAS UGe22 2006000196z | oMB-300-2008 Ea Re 28 RF EE ae eked rH iis CHINA NATIONAL CENTRE FOR QUALITY SUPERVISION AND TEST OF INSULATORS AND SURGE ARRESTERS je Oe tk A TEST REPORT HY10"—36 Polymeric Housed Metal Object i * = Re Oxide Surge Arrester Without Gaps Client i I a Pe yy Xianefan TTE Electric Co.,Ltd. Classification T i mx) Type Test + EW XIAN P.R CHINA CHINA NATIONAL CENTRE FOR QUALITY SUPERVISION AND TEST OF INSULATORS AND SURGE ARRESTERS TEST REPORT NO.wB—300—2008 Pee ot Polymeric Housed Metal Oxide Type HY1oW—36 ‘Name Surge Arrester Without Gaps ‘Trade Mark TTE Consignor | Xiangfan TTE Electric Co.,Ltd. | Manufacturer Xiangfan TTE Electric Co.,Ltd. Representative Wan Lei Classification Type Test ‘The west suburb of Zaoyang ‘Telephone +86-710-6215833 ee city.Hubei,China |__| 441200 Fax, +86-710-6215833 Samples Received 2008.12.15 Quantity of |Arrester:4, Ratio arrester:1, Date Samples Ratio housing:1, Section:15, Housing? Test Date 2008.12.17 ~2009.01.29 |Arrester:1~3; Section:R1 ~R3,01~03,LI~L3, Al~A3;_ Ratio arrester:BL;, Serial Number| Ratio housingr:W1; Housing :HI Test Judge | IEC 60099-4:2006-07 Metal-onide surge arresters without gaps for a.c. systems |All test items see page 2 of this report. ‘this surge arrester pass all 8 items of type test and is deem ‘Test [Standards specifications. Conclusion e009 025 1, Thi series of produets include 12 type: 10W-36, HY10W-33,_HY10W-30, HY 10W-27. HY1OW-24, HY1OW-21. HYLOW-18. HYLOW-15. HY1OW-12. HYLOW-9, HY10W-6, HY10W-3.All technical parameter and size please see annex 1, Remarks and all product drawing please see annex 2. 2. The longest electrical unit and mechanical unit is HY 10W-36 in this series of products. 5.At the report, HY 10W-36 is represented in this series of product ,but some test parameter have adopted the most strict parameter in all this series of products, Approved: Aw mst Editor: 4. By Test-leader: AE Confimnitd oi (CHINA NATIONAL CENTRE FOR QUALITY SUPERVISION AND TEST OF INSULATORS AND SURGE ARRESTERS TEST REPORT ‘wa —300—2008 page 2 of 34 Type Test Items Test Items Req. ‘Test Data | Result Partial discharge test <10 pc Spc passed 8/20p18 Ujoua 105.6 KV 93.7 kV [Residual voltage test V/Spts U joey 122.4 kV 1082 kv | Passed . . 40/1008 Uso94<90.0 kV 79.8kV [Long duration current : nici alia te ‘Should pass Class 1 line discharge passed passed Operating duty test 410s, 100 kA passed — | passed Performing suphur dioxide test mental test i Enviro: cand salt mist test. passed | passed Lightning impulse withstand 138 kV, 15 times positive and negative; 6 | Insulation withstand test passed — | passed . Power frequence voltage wet withstand 96 kV, 1 min Withstand 60°C—+>-25°C-+45°C=»-40°T heat-cool ,boiling 42h in boiled 0.1%6Nacl | Moist test d se 7 Moluane mares waterjimmersing 50°C water, test within 8h | PSS* passed after taking out i 8 |Weather ageing test Applied Ue 1000 hours in salt fog passed | passed || Test Conclusion: Satisfied.

You might also like