Aluminium-alloy IP65 single point load cell. Colourless anodized Suitable for pricing scales, bench scales, etc. Recommended platform size: 200 x 200mm
Specification:
Accuracy class Output sensitivity ( = FS ) Maximum capacity (Emax) Maximum number of load cell intervals ( nLC ) Ratio of minimum LC verification interval Y = Emax / vmin Combined Error Safe overload Ultimate overload Zero balance Excitation, recommended voltage Excitation maximum Terminal resistance, input Terminal resistance, output Insulation impedance Temperature range, compensated Temperature range, operating Element material Ingress Protection (according to EN 60529) Recommended torque on fixation bolts mV/V kg C3D 0.9 0.2 0.3, 0.6, 1.2, 3 2500 5000 0.0300 150 % 300 % < 1.0 % 5 ~ 12 18 394 6 350 3.5 5000 (at 50VDC ) -10 ~ +40 -20 ~ +50 Aluminium IP65 1.3
M C C
Nm